  "title": "Cold-Applied Liquid Waterproofing Membrane Volume Calculator",
  "description": "Calculate the liquid waterproofing material needed to achieve a target dry film thickness, accounting for solids content.",
  "url": "https://craftquantities.com/calculators/materials-quantities/liquid-waterproofing-volume-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/liquid-waterproofing-volume-calculator.json",
  "inputCount": 3,
  "testCaseCount": 2,
  "sourceCount": 1,
  "lastVerified": "2026-09-06",
  "translations": {
    "es-US": "https://craftquantities.com/es/calculators/materials-quantities/liquid-waterproofing-volume-calculator/"
  },
  "citation": {
    "author": "Craft Quantities",
    "title": "Cold-Applied Liquid Waterproofing Membrane Volume Calculator",
    "version": "1.0.1",
    "sourcesChecked": "2026-09-06",
    "url": "https://craftquantities.com/calculators/materials-quantities/liquid-waterproofing-volume-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. Cold-Applied Liquid Waterproofing Membrane Volume Calculator. Version 1.0.1. Sources checked 2026-09-06. https://craftquantities.com/calculators/materials-quantities/liquid-waterproofing-volume-calculator/",
      "apa": "Craft Quantities. (2026). Cold-Applied Liquid Waterproofing Membrane Volume Calculator (Version 1.0.1) [Web calculator]. Retrieved from https://craftquantities.com/calculators/materials-quantities/liquid-waterproofing-volume-calculator/",
      "harvard": "Craft Quantities (2026) Cold-Applied Liquid Waterproofing Membrane Volume Calculator (Version 1.0.1). Available at: https://craftquantities.com/calculators/materials-quantities/liquid-waterproofing-volume-calculator/",
      "bibtex": "@misc{craftquantities-calculators-materials-quantities-liquid-waterproofing-volume-calculator,\n  author       = {{Craft Quantities}},\n  title        = {Cold-Applied Liquid Waterproofing Membrane Volume Calculator},\n  version      = {1.0.1},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/materials-quantities/liquid-waterproofing-volume-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "area",
      "label": "Area to Waterproof",
      "type": "number",
      "dimension": "area",
      "defaultValue": 50,
      "min": 0.01,
      "max": 500,
      "step": 0.5,
      "help": "The total surface area to be waterproofed."
    },
    {
      "id": "dryFilmThickness",
      "label": "Target Dry Film Thickness (mils)",
      "type": "number",
      "defaultValue": 60,
      "min": 20,
      "max": 120,
      "step": 5,
      "help": "The cured (dry) membrane thickness required by the manufacturer's spec."
    },
    {
      "id": "solidsContent",
      "label": "Product Solids Content (%)",
      "type": "number",
      "defaultValue": 80,
      "min": 40,
      "max": 100,
      "step": 1,
      "help": "The percentage of the wet product that remains after solvent/water evaporates during cure."
    }
  ],
  "sources": [
    {
      "label": "Wet film thickness = target dry film thickness ÷ solids content fraction, since liquid-applied membranes lose volume as solvent/water evaporates during cure; material volume = area × wet film thickness"
    }
  ],
  "testCases": [
    {
      "name": "50m², 60 mil DFT, 80% solids",
      "inputs": {
        "area": 50,
        "dryFilmThickness": 60,
        "solidsContent": 80
      },
      "expected": 95.25,
      "toleranceDecimalPlaces": 2,
      "unit": "L",
      "confidence": "medium",
      "steps": [
        {
          "label": "Required wet film thickness",
          "value": 75,
          "unit": "mils"
        }
      ],
      "basis": "sole-source",
      "sourceIndex": 0
    },
    {
      "name": "70m², 80 mil DFT, 75% solids",
      "inputs": {
        "area": 70,
        "dryFilmThickness": 80,
        "solidsContent": 75
      },
      "expected": 189.65,
      "toleranceDecimalPlaces": 2,
      "unit": "L",
      "confidence": "medium",
      "steps": [
        {
          "label": "Required wet film thickness",
          "value": 106.66666666666667,
          "unit": "mils"
        }
      ],
      "basis": "sole-source",
      "sourceIndex": 0
    }
  ],
  "usedByAssemblies": [
    {
      "id": "flat-roof-replacement",
      "name": "Flat roof replacement (warm roof)"
    },
    {
      "id": "loft-conversion-dormer",
      "name": "Loft conversion with a dormer"
    }
  ]
}