  "version": "v1",
  "source": "https://craftquantities.com",
  "licence": "CC BY 4.0",
  "licenceUrl": "https://creativecommons.org/licenses/by/4.0/",
  "attribution": "Craft Quantities — craftquantities.com",
  "documentation": "https://craftquantities.com/api/",
  "versioning": "Fields are added, never removed or repurposed, within a version. A breaking change becomes /api/v2/ and v1 keeps being built.",
  "slug": "lintel-bearing-length-calculator",
  "category": "materials-quantities",
  "title": "Masonry Lintel Bearing Length Checker",
  "description": "Check whether a lintel's end bearing length meets standard code minimums.",
  "url": "https://craftquantities.com/calculators/materials-quantities/lintel-bearing-length-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/lintel-bearing-length-calculator.json",
  "inputCount": 2,
  "testCaseCount": 2,
  "sourceCount": 1,
  "lastVerified": "2026-09-06",
  "translations": {
    "es-US": "https://craftquantities.com/es/calculators/materials-quantities/lintel-bearing-length-calculator/"
  },
  "citation": {
    "author": "Craft Quantities",
    "title": "Masonry Lintel Bearing Length Checker",
    "version": "1.0.1",
    "sourcesChecked": "2026-09-06",
    "url": "https://craftquantities.com/calculators/materials-quantities/lintel-bearing-length-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. Masonry Lintel Bearing Length Checker. Version 1.0.1. Sources checked 2026-09-06. https://craftquantities.com/calculators/materials-quantities/lintel-bearing-length-calculator/",
      "apa": "Craft Quantities. (2026). Masonry Lintel Bearing Length Checker (Version 1.0.1) [Web calculator]. Retrieved from https://craftquantities.com/calculators/materials-quantities/lintel-bearing-length-calculator/",
      "harvard": "Craft Quantities (2026) Masonry Lintel Bearing Length Checker (Version 1.0.1). Available at: https://craftquantities.com/calculators/materials-quantities/lintel-bearing-length-calculator/",
      "bibtex": "@misc{craftquantities-calculators-materials-quantities-lintel-bearing-length-calculator,\n  author       = {{Craft Quantities}},\n  title        = {Masonry Lintel Bearing Length Checker},\n  version      = {1.0.1},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/materials-quantities/lintel-bearing-length-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "providedBearingLength",
      "label": "Provided Bearing Length",
      "type": "number",
      "dimension": "length",
      "defaultValue": 0.1524,
      "min": 0.01,
      "max": 0.6096,
      "step": 0.0127,
      "help": "The actual bearing length provided on each end of the lintel."
    },
    {
      "id": "lintelType",
      "label": "Lintel Type",
      "type": "select",
      "defaultValue": "general",
      "optionsBySystem": {
        "imperial": [
          {
            "value": "general",
            "label": "General masonry opening (4 in code minimum)"
          },
          {
            "value": "steel-reinforced",
            "label": "Steel or reinforced masonry lintel (5 in minimum)"
          },
          {
            "value": "concrete-pca",
            "label": "Concrete lintel (6 in PCA-recommended)"
          }
        ],
        "metric": [
          {
            "value": "general",
            "label": "General masonry opening (102 mm / 4 in code minimum)"
          },
          {
            "value": "steel-reinforced",
            "label": "Steel or reinforced masonry lintel (127 mm / 5 in minimum)"
          },
          {
            "value": "concrete-pca",
            "label": "Concrete lintel (153 mm / 6 in PCA-recommended)"
          }
        ]
      },
      "help": "The type of lintel, which sets the applicable minimum bearing length."
    }
  ],
  "sources": [
    {
      "label": "Standard building code minimum lintel bearing length is 4 in on each end; steel or reinforced masonry lintels require at least 5 in bearing; the Portland Cement Association recommends a minimum of 6 in for concrete lintels"
    }
  ],
  "testCases": [
    {
      "name": "4in provided, general (4in min, pass)",
      "inputs": {
        "providedBearingLength": 0.1016,
        "lintelType": "general"
      },
      "expected": 4,
      "toleranceDecimalPlaces": 0,
      "unit": "in",
      "confidence": "medium",
      "steps": [
        {
          "label": "Required minimum",
          "value": 4,
          "unit": "in"
        }
      ],
      "basis": "sole-source",
      "sourceIndex": 0
    },
    {
      "name": "4in provided, steel-reinforced (5in min, fail)",
      "inputs": {
        "providedBearingLength": 0.1016,
        "lintelType": "steel-reinforced"
      },
      "expected": 4,
      "toleranceDecimalPlaces": 0,
      "unit": "in",
      "confidence": "medium",
      "steps": [
        {
          "label": "Required minimum",
          "value": 5,
          "unit": "in"
        }
      ],
      "basis": "sole-source",
      "sourceIndex": 0
    }
  ]
}