  "version": "v1",
  "source": "https://craftquantities.com",
  "licence": "CC BY 4.0",
  "licenceUrl": "https://creativecommons.org/licenses/by/4.0/",
  "attribution": "Craft Quantities — craftquantities.com",
  "documentation": "https://craftquantities.com/api/",
  "versioning": "Fields are added, never removed or repurposed, within a version. A breaking change becomes /api/v2/ and v1 keeps being built.",
  "slug": "lap-siding-fastener-schedule-calculator",
  "category": "materials-quantities",
  "title": "Lap Siding Fastener Schedule Calculator",
  "description": "Derive fastener count and boxes for a lap-clad elevation from its own geometry — height, run, exposure and stud spacing.",
  "url": "https://craftquantities.com/calculators/materials-quantities/lap-siding-fastener-schedule-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/lap-siding-fastener-schedule-calculator.json",
  "inputCount": 8,
  "testCaseCount": 3,
  "sourceCount": 3,
  "lastVerified": "2026-09-06",
  "translations": {
    "es-US": "https://craftquantities.com/es/calculators/materials-quantities/lap-siding-fastener-schedule-calculator/"
  },
  "citation": {
    "author": "Craft Quantities",
    "title": "Lap Siding Fastener Schedule Calculator",
    "version": "1.0.1",
    "sourcesChecked": "2026-09-06",
    "url": "https://craftquantities.com/calculators/materials-quantities/lap-siding-fastener-schedule-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. Lap Siding Fastener Schedule Calculator. Version 1.0.1. Sources checked 2026-09-06. https://craftquantities.com/calculators/materials-quantities/lap-siding-fastener-schedule-calculator/",
      "apa": "Craft Quantities. (2026). Lap Siding Fastener Schedule Calculator (Version 1.0.1) [Web calculator]. Retrieved from https://craftquantities.com/calculators/materials-quantities/lap-siding-fastener-schedule-calculator/",
      "harvard": "Craft Quantities (2026) Lap Siding Fastener Schedule Calculator (Version 1.0.1). Available at: https://craftquantities.com/calculators/materials-quantities/lap-siding-fastener-schedule-calculator/",
      "bibtex": "@misc{craftquantities-calculators-materials-quantities-lap-siding-fastener-schedule-calculator,\n  author       = {{Craft Quantities}},\n  title        = {Lap Siding Fastener Schedule Calculator},\n  version      = {1.0.1},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/materials-quantities/lap-siding-fastener-schedule-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "wallHeight",
      "label": "Elevation Height",
      "type": "number",
      "dimension": "length",
      "defaultValue": 2.7,
      "min": 0.5,
      "max": 12,
      "step": 0.1,
      "help": "The height of the clad area on this elevation."
    },
    {
      "id": "wallLength",
      "label": "Elevation Length",
      "type": "number",
      "dimension": "length",
      "defaultValue": 12,
      "min": 1,
      "max": 60,
      "step": 0.5,
      "help": "The horizontal run of the elevation being clad."
    },
    {
      "id": "exposure",
      "label": "Course Exposure",
      "type": "number",
      "dimension": "length",
      "defaultValue": 0.1778,
      "min": 0.075,
      "max": 0.35,
      "step": 0.005,
      "help": "The face of each board left showing once the lap above is set."
    },
    {
      "id": "studSpacing",
      "label": "Stud or Girt Spacing",
      "type": "number",
      "dimension": "length",
      "defaultValue": 0.4064,
      "min": 0.2,
      "max": 0.8,
      "step": 0.0254,
      "help": "Centre spacing of the studs or girts behind the cladding."
    },
    {
      "id": "fastenerPattern",
      "label": "Nailing Pattern",
      "type": "select",
      "defaultValue": "blind",
      "options": [
        {
          "value": "blind",
          "label": "Blind nailed — one fastener per stud through the top edge"
        },
        {
          "value": "face",
          "label": "Face nailed — one fastener per stud near the butt"
        },
        {
          "value": "both",
          "label": "Blind and face nailed — two fasteners per stud"
        }
      ],
      "help": "How the boards are fixed at each stud line."
    },
    {
      "id": "extraPerCourse",
      "label": "Extra Fasteners per Course",
      "type": "number",
      "defaultValue": 0,
      "min": 0,
      "max": 6,
      "step": 1,
      "help": "Additional fixings per course called for in a high-wind zone or at corners."
    },
    {
      "id": "fastenersPerBox",
      "label": "Fasteners per Box",
      "type": "number",
      "defaultValue": 800,
      "min": 50,
      "max": 5000,
      "step": 50,
      "help": "The count in one box of the fastener you are actually buying."
    },
    {
      "id": "wastePercent",
      "label": "Waste Allowance (%)",
      "type": "number",
      "defaultValue": 10,
      "min": 0,
      "max": 30,
      "step": 1,
      "help": "Extra for dropped, bent and misfired fixings."
    }
  ],
  "sources": [
    {
      "label": "Courses = wall height ÷ exposure, rounded up. Fastening points per course = the stud lines the elevation crosses, plus one for the far end, times the fasteners each pattern drives at a stud, plus any high-wind extras you enter."
    },
    {
      "label": "The manufacturer's evaluation report is the fastening schedule of record for fibre cement and engineered lap cladding — fastener type, length, penetration and pattern are product-specific and none of them is assumed here."
    },
    {
      "label": "ASCE/SEI 7, Minimum Design Loads and Associated Criteria for Buildings and Other Structures — the source of the component and cladding pressure that decides whether a high-wind pattern applies to this elevation"
    }
  ],
  "testCases": [
    {
      "name": "2.7 m by 12 m elevation, blind nailed at 406 mm centres",
      "inputs": {
        "wallHeight": 2.7,
        "wallLength": 12,
        "exposure": 0.1778,
        "studSpacing": 0.4064,
        "fastenerPattern": "blind",
        "extraPerCourse": 0,
        "fastenersPerBox": 800,
        "wastePercent": 10
      },
      "expected": 546,
      "toleranceDecimalPlaces": 0,
      "unit": "fasteners",
      "confidence": "high",
      "steps": [
        {
          "label": "Courses on this elevation",
          "value": 16,
          "unit": "courses"
        },
        {
          "label": "Stud lines the elevation crosses",
          "value": 31,
          "unit": "studs"
        },
        {
          "label": "Fastening points per course",
          "value": 31,
          "unit": "fasteners"
        },
        {
          "label": "Count before the waste allowance",
          "value": 496,
          "unit": "fasteners"
        },
        {
          "label": "Boxes to order",
          "value": 1,
          "unit": "boxes"
        }
      ],
      "includesAllowance": {
        "label": "Dropped and misfired fixing allowance",
        "percent": 10
      },
      "basis": "ambiguous"
    },
    {
      "name": "Same elevation blind and face nailed",
      "inputs": {
        "wallHeight": 2.7,
        "wallLength": 12,
        "exposure": 0.1778,
        "studSpacing": 0.4064,
        "fastenerPattern": "both",
        "extraPerCourse": 0,
        "fastenersPerBox": 800,
        "wastePercent": 10
      },
      "expected": 1092,
      "toleranceDecimalPlaces": 0,
      "unit": "fasteners",
      "confidence": "high",
      "steps": [
        {
          "label": "Courses on this elevation",
          "value": 16,
          "unit": "courses"
        },
        {
          "label": "Stud lines the elevation crosses",
          "value": 31,
          "unit": "studs"
        },
        {
          "label": "Fastening points per course",
          "value": 62,
          "unit": "fasteners"
        },
        {
          "label": "Count before the waste allowance",
          "value": 992,
          "unit": "fasteners"
        },
        {
          "label": "Boxes to order",
          "value": 2,
          "unit": "boxes"
        }
      ],
      "includesAllowance": {
        "label": "Dropped and misfired fixing allowance",
        "percent": 10
      },
      "basis": "ambiguous"
    },
    {
      "name": "3 m by 9 m at 610 mm centres, one high-wind extra, no waste",
      "inputs": {
        "wallHeight": 3,
        "wallLength": 9,
        "exposure": 0.2032,
        "studSpacing": 0.6096,
        "fastenerPattern": "face",
        "extraPerCourse": 1,
        "fastenersPerBox": 500,
        "wastePercent": 0
      },
      "expected": 255,
      "toleranceDecimalPlaces": 0,
      "unit": "fasteners",
      "confidence": "high",
      "steps": [
        {
          "label": "Courses on this elevation",
          "value": 15,
          "unit": "courses"
        },
        {
          "label": "Stud lines the elevation crosses",
          "value": 16,
          "unit": "studs"
        },
        {
          "label": "Fastening points per course",
          "value": 17,
          "unit": "fasteners"
        },
        {
          "label": "Count before the waste allowance",
          "value": 255,
          "unit": "fasteners"
        },
        {
          "label": "Boxes to order",
          "value": 1,
          "unit": "boxes"
        }
      ],
      "includesAllowance": {
        "label": "Dropped and misfired fixing allowance",
        "percent": 0
      },
      "basis": "ambiguous"
    }
  ],
  "usedByAssemblies": [
    {
      "id": "fiber-cement-siding",
      "name": "Fibre cement siding"
    }
  ]
}