  "version": "v1",
  "source": "https://craftquantities.com",
  "licence": "CC BY 4.0",
  "licenceUrl": "https://creativecommons.org/licenses/by/4.0/",
  "attribution": "Craft Quantities — craftquantities.com",
  "documentation": "https://craftquantities.com/api/",
  "versioning": "Fields are added, never removed or repurposed, within a version. A breaking change becomes /api/v2/ and v1 keeps being built.",
  "slug": "insulation-thickness-target-u-value-calculator",
  "category": "insulation-efficiency",
  "title": "Insulation Thickness for a Target U-Value Calculator (BS EN ISO 6946)",
  "description": "The insulation thickness a target U-value needs, from the other layers and the product's conductivity, and the U-value a board you can buy reaches.",
  "url": "https://craftquantities.com/calculators/insulation-efficiency/insulation-thickness-target-u-value-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/insulation-thickness-target-u-value-calculator.json",
  "inputCount": 6,
  "testCaseCount": 5,
  "sourceCount": 3,
  "lastVerified": "2026-09-22",
  "citation": {
    "author": "Craft Quantities",
    "title": "Insulation Thickness for a Target U-Value Calculator (BS EN ISO 6946)",
    "version": "1.0.0",
    "sourcesChecked": "2026-09-22",
    "url": "https://craftquantities.com/calculators/insulation-efficiency/insulation-thickness-target-u-value-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. Insulation Thickness for a Target U-Value Calculator (BS EN ISO 6946). Version 1.0.0. Sources checked 2026-09-22. https://craftquantities.com/calculators/insulation-efficiency/insulation-thickness-target-u-value-calculator/",
      "apa": "Craft Quantities. (2026). Insulation Thickness for a Target U-Value Calculator (BS EN ISO 6946) (Version 1.0.0) [Web calculator]. Retrieved from https://craftquantities.com/calculators/insulation-efficiency/insulation-thickness-target-u-value-calculator/",
      "harvard": "Craft Quantities (2026) Insulation Thickness for a Target U-Value Calculator (BS EN ISO 6946) (Version 1.0.0). Available at: https://craftquantities.com/calculators/insulation-efficiency/insulation-thickness-target-u-value-calculator/",
      "bibtex": "@misc{craftquantities-calculators-insulation-efficiency-insulation-thickness-target-u-value-calculator,\n  author       = {{Craft Quantities}},\n  title        = {Insulation Thickness for a Target U-Value Calculator (BS EN ISO 6946)},\n  version      = {1.0.0},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/insulation-efficiency/insulation-thickness-target-u-value-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "targetU",
      "label": "Target U-Value",
      "type": "number",
      "dimension": "uvalue",
      "defaultValue": 0.18,
      "min": 0.05,
      "max": 3,
      "step": 0.01,
      "help": "The U-value the element has to reach, from the regulation or specification for this job."
    },
    {
      "id": "heatFlow",
      "label": "Element and Direction of Heat Flow",
      "type": "select",
      "defaultValue": "horizontal",
      "options": [
        {
          "value": "horizontal",
          "label": "Wall — heat flows sideways"
        },
        {
          "value": "upward",
          "label": "Roof or ceiling — heat flows upwards"
        },
        {
          "value": "downward",
          "label": "Floor over outside air — heat flows downwards"
        }
      ],
      "help": "Sets the internal surface resistance, which depends on which way the heat is flowing."
    },
    {
      "id": "outerFace",
      "label": "What the Outside of the Construction Faces",
      "type": "select",
      "defaultValue": "outside",
      "options": [
        {
          "value": "outside",
          "label": "The outside air"
        },
        {
          "value": "ventilated",
          "label": "A well-ventilated air layer (a vented roof or rainscreen)"
        }
      ],
      "help": "A well-ventilated cavity counts for nothing, and nor does anything outside it."
    },
    {
      "id": "otherLayers",
      "label": "Thermal Resistance of the Other Layers",
      "type": "number",
      "dimension": "rvalue",
      "defaultValue": 0.5,
      "min": 0,
      "max": 20,
      "step": 0.01,
      "help": "Everything in the construction except the new insulation and the two surface films, added together."
    },
    {
      "id": "conductivity",
      "label": "Thermal Conductivity of the Insulation (λ)",
      "type": "number",
      "dimension": "conductivity",
      "defaultValue": 0.022,
      "min": 0.012,
      "max": 0.2,
      "step": 0.001,
      "help": "The declared conductivity on the product's certificate, at the thickness you are buying."
    },
    {
      "id": "boardThickness",
      "label": "A Board Thickness to Check (0 to skip)",
      "type": "number",
      "dimension": "length",
      "defaultValue": 0,
      "min": 0,
      "max": 0.6,
      "step": 0.005,
      "help": "The thickness you can actually buy, to see the U-value it reaches with the rest of the construction."
    }
  ],
  "sources": [
    {
      "label": "BS EN ISO 6946:2017, Building components and building elements — Thermal resistance and thermal transmittance: U = 1 ÷ (Rsi + ΣR + Rse), each layer's resistance its thickness ÷ λ; surface resistances in 6.8, a well-ventilated air layer in 6.9.4"
    },
    {
      "label": "Surface resistances as tabulated for heat flow upwards 0.10, horizontal 0.13 and downwards 0.17 m²K/W, and 0.04 m²K/W outside (BS EN ISO 13788:2012 Table 2 and 4.4.1 carry the same values)"
    },
    {
      "label": "Declared thermal conductivity λD from the product standards — BS EN 13165 (PIR and PUR), BS EN 13163 (EPS), BS EN 13162 (mineral wool)"
    }
  ],
  "testCases": [
    {
      "name": "The sloping-ceiling guide: 0.18 target under a vented roof, 50 mm of PIR between the rafters",
      "inputs": {
        "targetU": 0.18,
        "heatFlow": "upward",
        "outerFace": "ventilated",
        "otherLayers": 2.272727272727273,
        "conductivity": 0.022,
        "boardThickness": 0
      },
      "expected": 67.8222,
      "toleranceDecimalPlaces": 3,
      "unit": "mm",
      "confidence": "high",
      "steps": [
        {
          "label": "Total resistance the target asks for (1 ÷ U)",
          "value": 5.555555555555555,
          "unit": "m²K/W"
        },
        {
          "label": "Internal surface resistance",
          "value": 0.1,
          "unit": "m²K/W"
        },
        {
          "label": "External surface resistance",
          "value": 0.1,
          "unit": "m²K/W"
        },
        {
          "label": "The other layers",
          "value": 2.272727272727273,
          "unit": "m²K/W"
        },
        {
          "label": "Resistance the insulation has to supply",
          "value": 3.082828282828283,
          "unit": "m²K/W"
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    },
    {
      "name": "A wall at 0.18 with 0.5 m²K/W of other layers, PIR at 0.022",
      "inputs": {
        "targetU": 0.18,
        "heatFlow": "horizontal",
        "outerFace": "outside",
        "otherLayers": 0.5,
        "conductivity": 0.022,
        "boardThickness": 0
      },
      "expected": 107.4822,
      "toleranceDecimalPlaces": 3,
      "unit": "mm",
      "confidence": "high",
      "steps": [
        {
          "label": "Total resistance the target asks for (1 ÷ U)",
          "value": 5.555555555555555,
          "unit": "m²K/W"
        },
        {
          "label": "Internal surface resistance",
          "value": 0.13,
          "unit": "m²K/W"
        },
        {
          "label": "External surface resistance",
          "value": 0.04,
          "unit": "m²K/W"
        },
        {
          "label": "The other layers",
          "value": 0.5,
          "unit": "m²K/W"
        },
        {
          "label": "Resistance the insulation has to supply",
          "value": 4.885555555555555,
          "unit": "m²K/W"
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    },
    {
      "name": "The same wall in EPS at 0.038 — the garage guide's 'roughly seventy per cent thicker'",
      "inputs": {
        "targetU": 0.18,
        "heatFlow": "horizontal",
        "outerFace": "outside",
        "otherLayers": 0.5,
        "conductivity": 0.038,
        "boardThickness": 0
      },
      "expected": 185.6511,
      "toleranceDecimalPlaces": 3,
      "unit": "mm",
      "confidence": "high",
      "steps": [
        {
          "label": "Total resistance the target asks for (1 ÷ U)",
          "value": 5.555555555555555,
          "unit": "m²K/W"
        },
        {
          "label": "Internal surface resistance",
          "value": 0.13,
          "unit": "m²K/W"
        },
        {
          "label": "External surface resistance",
          "value": 0.04,
          "unit": "m²K/W"
        },
        {
          "label": "The other layers",
          "value": 0.5,
          "unit": "m²K/W"
        },
        {
          "label": "Resistance the insulation has to supply",
          "value": 4.885555555555555,
          "unit": "m²K/W"
        }
      ],
      "basis": "cited",
      "sourceIndex": 2
    },
    {
      "name": "A floor over outside air: heat flows down, Rsi 0.17",
      "inputs": {
        "targetU": 0.18,
        "heatFlow": "downward",
        "outerFace": "outside",
        "otherLayers": 0.3,
        "conductivity": 0.032,
        "boardThickness": 0
      },
      "expected": 161.4578,
      "toleranceDecimalPlaces": 3,
      "unit": "mm",
      "confidence": "high",
      "steps": [
        {
          "label": "Total resistance the target asks for (1 ÷ U)",
          "value": 5.555555555555555,
          "unit": "m²K/W"
        },
        {
          "label": "Internal surface resistance",
          "value": 0.17,
          "unit": "m²K/W"
        },
        {
          "label": "External surface resistance",
          "value": 0.04,
          "unit": "m²K/W"
        },
        {
          "label": "The other layers",
          "value": 0.3,
          "unit": "m²K/W"
        },
        {
          "label": "Resistance the insulation has to supply",
          "value": 5.045555555555556,
          "unit": "m²K/W"
        }
      ],
      "basis": "cited",
      "sourceIndex": 1
    },
    {
      "name": "A target the other layers already reach needs no insulation",
      "inputs": {
        "targetU": 1.5,
        "heatFlow": "horizontal",
        "outerFace": "outside",
        "otherLayers": 1,
        "conductivity": 0.022,
        "boardThickness": 0
      },
      "expected": 0,
      "toleranceDecimalPlaces": 3,
      "unit": "mm",
      "confidence": "high",
      "steps": [
        {
          "label": "Total resistance the target asks for (1 ÷ U)",
          "value": 0.6666666666666666,
          "unit": "m²K/W"
        },
        {
          "label": "Internal surface resistance",
          "value": 0.13,
          "unit": "m²K/W"
        },
        {
          "label": "External surface resistance",
          "value": 0.04,
          "unit": "m²K/W"
        },
        {
          "label": "The other layers",
          "value": 1,
          "unit": "m²K/W"
        },
        {
          "label": "Resistance the insulation has to supply",
          "value": 0,
          "unit": "m²K/W"
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    }
  ]
}