  "version": "v1",
  "source": "https://craftquantities.com",
  "licence": "CC BY 4.0",
  "licenceUrl": "https://creativecommons.org/licenses/by/4.0/",
  "attribution": "Craft Quantities — craftquantities.com",
  "documentation": "https://craftquantities.com/api/",
  "versioning": "Fields are added, never removed or repurposed, within a version. A breaking change becomes /api/v2/ and v1 keeps being built.",
  "slug": "i-joist-bearing-length-calculator",
  "category": "materials-quantities",
  "title": "I-Joist Web Stiffener Bearing Length Calculator",
  "description": "Calculate the required bearing length for an I-joist reaction, to check whether a web stiffener is needed.",
  "url": "https://craftquantities.com/calculators/materials-quantities/i-joist-bearing-length-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/i-joist-bearing-length-calculator.json",
  "inputCount": 3,
  "testCaseCount": 2,
  "sourceCount": 1,
  "lastVerified": "2026-09-06",
  "citation": {
    "author": "Craft Quantities",
    "title": "I-Joist Web Stiffener Bearing Length Calculator",
    "version": "1.0.1",
    "sourcesChecked": "2026-09-06",
    "url": "https://craftquantities.com/calculators/materials-quantities/i-joist-bearing-length-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. I-Joist Web Stiffener Bearing Length Calculator. Version 1.0.1. Sources checked 2026-09-06. https://craftquantities.com/calculators/materials-quantities/i-joist-bearing-length-calculator/",
      "apa": "Craft Quantities. (2026). I-Joist Web Stiffener Bearing Length Calculator (Version 1.0.1) [Web calculator]. Retrieved from https://craftquantities.com/calculators/materials-quantities/i-joist-bearing-length-calculator/",
      "harvard": "Craft Quantities (2026) I-Joist Web Stiffener Bearing Length Calculator (Version 1.0.1). Available at: https://craftquantities.com/calculators/materials-quantities/i-joist-bearing-length-calculator/",
      "bibtex": "@misc{craftquantities-calculators-materials-quantities-i-joist-bearing-length-calculator,\n  author       = {{Craft Quantities}},\n  title        = {I-Joist Web Stiffener Bearing Length Calculator},\n  version      = {1.0.1},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/materials-quantities/i-joist-bearing-length-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "reactionLoad",
      "label": "Reaction Load",
      "type": "number",
      "dimension": "force",
      "defaultValue": 5000,
      "min": 500,
      "max": 30000,
      "step": 100,
      "help": "The end reaction load the I-joist transfers into its bearing support."
    },
    {
      "id": "allowableBearingStress",
      "label": "Allowable Bearing Stress",
      "type": "number",
      "dimension": "pressure",
      "defaultValue": 2500000,
      "min": 1000000,
      "max": 6000000,
      "step": 100000,
      "help": "The allowable compression stress perpendicular to the flange, from the manufacturer's design values."
    },
    {
      "id": "flangeWidth",
      "label": "Flange Width",
      "type": "number",
      "dimension": "length",
      "defaultValue": 0.045,
      "min": 0.01,
      "max": 0.09,
      "step": 0.001,
      "help": "The width of the I-joist's bottom flange, which is the bearing contact surface."
    }
  ],
  "sources": [
    {
      "label": "Required bearing length = reaction load ÷ (allowable bearing stress × flange width); if the provided/actual bearing length is less than this, a web stiffener is typically required per the I-joist manufacturer's installation guide"
    }
  ],
  "testCases": [
    {
      "name": "5000N reaction, 2.5MPa, 45mm flange",
      "inputs": {
        "reactionLoad": 5000,
        "allowableBearingStress": 2500000,
        "flangeWidth": 0.045
      },
      "expected": 44.44,
      "toleranceDecimalPlaces": 2,
      "unit": "mm",
      "confidence": "medium",
      "steps": [],
      "basis": "sole-source",
      "sourceIndex": 0
    },
    {
      "name": "8000N reaction, 3MPa, 57mm flange",
      "inputs": {
        "reactionLoad": 8000,
        "allowableBearingStress": 3000000,
        "flangeWidth": 0.057
      },
      "expected": 46.78,
      "toleranceDecimalPlaces": 2,
      "unit": "mm",
      "confidence": "medium",
      "steps": [],
      "basis": "sole-source",
      "sourceIndex": 0
    }
  ]
}