  "category": "plumbing-hvac",
  "title": "Heat Pump Sizing Calculator",
  "description": "Size a heat pump to a known heat loss, and find the balance point where supplementary heat starts to be needed.",
  "url": "https://craftquantities.com/calculators/plumbing-hvac/heat-pump-sizing-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/heat-pump-sizing-calculator.json",
  "inputCount": 4,
  "testCaseCount": 4,
  "sourceCount": 3,
  "lastVerified": "2026-09-03",
  "translations": {
    "es-US": "https://craftquantities.com/es/calculators/plumbing-hvac/heat-pump-sizing-calculator/"
  },
  "citation": {
    "author": "Craft Quantities",
    "title": "Heat Pump Sizing Calculator",
    "version": "1.1.1",
    "sourcesChecked": "2026-09-03",
    "url": "https://craftquantities.com/calculators/plumbing-hvac/heat-pump-sizing-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. Heat Pump Sizing Calculator. Version 1.1.1. Sources checked 2026-09-03. https://craftquantities.com/calculators/plumbing-hvac/heat-pump-sizing-calculator/",
      "apa": "Craft Quantities. (2026). Heat Pump Sizing Calculator (Version 1.1.1) [Web calculator]. Retrieved from https://craftquantities.com/calculators/plumbing-hvac/heat-pump-sizing-calculator/",
      "harvard": "Craft Quantities (2026) Heat Pump Sizing Calculator (Version 1.1.1). Available at: https://craftquantities.com/calculators/plumbing-hvac/heat-pump-sizing-calculator/",
      "bibtex": "@misc{craftquantities-calculators-plumbing-hvac-heat-pump-sizing-calculator,\n  author       = {{Craft Quantities}},\n  title        = {Heat Pump Sizing Calculator},\n  version      = {1.1.1},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/plumbing-hvac/heat-pump-sizing-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "designHeatLossKw",
      "label": "Design heat loss",
      "type": "number",
      "dimension": "thermal",
      "defaultValue": 8000,
      "min": 500,
      "max": 200000,
      "step": 100,
      "help": "Whole-house heat loss at the design outdoor temperature."
    },
    {
      "id": "designOutdoorC",
      "label": "Design outdoor temperature",
      "type": "number",
      "dimension": "temperature",
      "defaultValue": -3,
      "min": -40,
      "max": 20,
      "step": 1,
      "help": "The external design condition for your location."
    },
    {
      "id": "ratedCapacityKw",
      "label": "Rated capacity at 7 °C",
      "type": "number",
      "dimension": "thermal",
      "defaultValue": 8000,
      "min": 500,
      "max": 200000,
      "step": 100,
      "help": "The heat pump's nameplate output at the standard rating point."
    },
    {
      "id": "capacityDeratePerDegree",
      "label": "Capacity loss per °C below rating point (%)",
      "type": "number",
      "defaultValue": 2,
      "min": 0,
      "max": 6,
      "step": 0.1,
      "help": "How fast output falls as it gets colder, per °C."
    }
  ],
  "sources": [
    {
      "label": "Heat pump capacity falls with outdoor temperature; manufacturers publish capacity tables at 47/17/5 °F (8/−8/−15 °C)"
    },
    {
      "label": "ACCA Manual S — equipment selection against the calculated load, including balance-point analysis for heat pumps"
    },
    {
      "label": "MCS 3005 (UK) requires sizing to the calculated design heat loss rather than to the existing boiler output"
    }
  ],
  "testCases": [
    {
      "name": "8 kW load, 8 kW rated, −3 °C design, 2%/°C",
      "inputs": {
        "designHeatLossKw": 8000,
        "designOutdoorC": -3,
        "ratedCapacityKw": 8000,
        "capacityDeratePerDegree": 2
      },
      "expected": 8,
      "toleranceDecimalPlaces": 1,
      "unit": "kW at design",
      "confidence": "medium",
      "steps": [
        {
          "label": "Nameplate capacity at 7 °C",
          "value": 8,
          "unit": "kW"
        },
        {
          "label": "Capacity at the design temperature",
          "value": 6.4,
          "unit": "kW"
        },
        {
          "label": "Shortfall needing supplementary heat",
          "value": 1.5999999999999996,
          "unit": "kW"
        },
        {
          "label": "Balance point",
          "value": 0,
          "unit": "°C"
        },
        {
          "label": "Capacity retained at design",
          "value": 80,
          "unit": "%"
        }
      ],
      "basis": "ambiguous"
    },
    {
      "name": "A larger load reports a larger requirement",
      "inputs": {
        "designHeatLossKw": 12000,
        "designOutdoorC": -3,
        "ratedCapacityKw": 8000,
        "capacityDeratePerDegree": 2
      },
      "expected": 12,
      "toleranceDecimalPlaces": 0,
      "unit": "kW at design",
      "confidence": "medium",
      "steps": [
        {
          "label": "Nameplate capacity at 7 °C",
          "value": 8,
          "unit": "kW"
        },
        {
          "label": "Capacity at the design temperature",
          "value": 6.4,
          "unit": "kW"
        },
        {
          "label": "Shortfall needing supplementary heat",
          "value": 5.6,
          "unit": "kW"
        },
        {
          "label": "Balance point",
          "value": 5,
          "unit": "°C"
        },
        {
          "label": "Capacity retained at design",
          "value": 80,
          "unit": "%"
        }
      ],
      "basis": "ambiguous"
    },
    {
      "name": "A colder design point",
      "inputs": {
        "designHeatLossKw": 8000,
        "designOutdoorC": -15,
        "ratedCapacityKw": 8000,
        "capacityDeratePerDegree": 2
      },
      "expected": 8,
      "toleranceDecimalPlaces": 1,
      "unit": "kW at design",
      "confidence": "medium",
      "steps": [
        {
          "label": "Nameplate capacity at 7 °C",
          "value": 8,
          "unit": "kW"
        },
        {
          "label": "Capacity at the design temperature",
          "value": 4.48,
          "unit": "kW"
        },
        {
          "label": "Shortfall needing supplementary heat",
          "value": 3.5199999999999996,
          "unit": "kW"
        },
        {
          "label": "Balance point",
          "value": -6,
          "unit": "°C"
        },
        {
          "label": "Capacity retained at design",
          "value": 56.00000000000001,
          "unit": "%"
        }
      ],
      "basis": "ambiguous"
    },
    {
      "name": "A small load",
      "inputs": {
        "designHeatLossKw": 4000,
        "designOutdoorC": -3,
        "ratedCapacityKw": 8000,
        "capacityDeratePerDegree": 2
      },
      "expected": 4,
      "toleranceDecimalPlaces": 1,
      "unit": "kW at design",
      "confidence": "medium",
      "steps": [
        {
          "label": "Nameplate capacity at 7 °C",
          "value": 8,
          "unit": "kW"
        },
        {
          "label": "Capacity at the design temperature",
          "value": 6.4,
          "unit": "kW"
        },
        {
          "label": "Shortfall needing supplementary heat",
          "value": 0,
          "unit": "kW"
        },
        {
          "label": "Balance point",
          "value": -10.5,
          "unit": "°C"
        },
        {
          "label": "Capacity retained at design",
          "value": 80,
          "unit": "%"
        }
      ],
      "basis": "ambiguous"
    }
  ]
}