  "version": "v1",
  "source": "https://craftquantities.com",
  "licence": "CC BY 4.0",
  "licenceUrl": "https://creativecommons.org/licenses/by/4.0/",
  "attribution": "Craft Quantities — craftquantities.com",
  "documentation": "https://craftquantities.com/api/",
  "versioning": "Fields are added, never removed or repurposed, within a version. A breaking change becomes /api/v2/ and v1 keeps being built.",
  "slug": "hearing-protection-attenuation-calculator",
  "category": "sustainability-compliance",
  "title": "Hearing Protection Attenuation Calculator (SNR, HML, NRR)",
  "description": "Estimate the noise reaching the ear under an earplug or earmuff from its SNR, HML or NRR rating, with the real-world allowance HSE and OSHA each apply.",
  "url": "https://craftquantities.com/calculators/sustainability-compliance/hearing-protection-attenuation-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/hearing-protection-attenuation-calculator.json",
  "inputCount": 10,
  "testCaseCount": 5,
  "sourceCount": 3,
  "lastVerified": "2026-09-21",
  "citation": {
    "author": "Craft Quantities",
    "title": "Hearing Protection Attenuation Calculator (SNR, HML, NRR)",
    "version": "1.0.0",
    "sourcesChecked": "2026-09-21",
    "url": "https://craftquantities.com/calculators/sustainability-compliance/hearing-protection-attenuation-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. Hearing Protection Attenuation Calculator (SNR, HML, NRR). Version 1.0.0. Sources checked 2026-09-21. https://craftquantities.com/calculators/sustainability-compliance/hearing-protection-attenuation-calculator/",
      "apa": "Craft Quantities. (2026). Hearing Protection Attenuation Calculator (SNR, HML, NRR) (Version 1.0.0) [Web calculator]. Retrieved from https://craftquantities.com/calculators/sustainability-compliance/hearing-protection-attenuation-calculator/",
      "harvard": "Craft Quantities (2026) Hearing Protection Attenuation Calculator (SNR, HML, NRR) (Version 1.0.0). Available at: https://craftquantities.com/calculators/sustainability-compliance/hearing-protection-attenuation-calculator/",
      "bibtex": "@misc{craftquantities-calculators-sustainability-compliance-hearing-protection-attenuation-calculator,\n  author       = {{Craft Quantities}},\n  title        = {Hearing Protection Attenuation Calculator (SNR, HML, NRR)},\n  version      = {1.0.0},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/sustainability-compliance/hearing-protection-attenuation-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "method",
      "label": "Rating on the Protector",
      "type": "select",
      "defaultValue": "snr",
      "options": [
        {
          "value": "snr",
          "label": "SNR — single number rating (UK, EU and most of the world)"
        },
        {
          "value": "hml",
          "label": "H, M and L values (UK and EU)"
        },
        {
          "value": "nrr",
          "label": "NRR — noise reduction rating (US)"
        }
      ],
      "help": "Which rating the packaging or data sheet gives."
    },
    {
      "id": "laeq",
      "label": "A-Weighted Noise Level, LAeq (dB(A))",
      "type": "number",
      "defaultValue": 95,
      "min": 60,
      "max": 140,
      "step": 0.1,
      "help": "The measured A-weighted level at the worker's position — used by the HML and A-weighted NRR methods."
    },
    {
      "id": "lceq",
      "label": "C-Weighted Noise Level, LCeq (dB(C))",
      "type": "number",
      "defaultValue": 98,
      "min": 60,
      "max": 140,
      "step": 0.1,
      "help": "The measured C-weighted level at the same position — used by the SNR, HML and C-weighted NRR methods."
    },
    {
      "id": "snr",
      "label": "SNR (dB)",
      "type": "number",
      "defaultValue": 30,
      "min": 5,
      "max": 45,
      "step": 1,
      "help": "The single number rating printed on the protector."
    },
    {
      "id": "hValue",
      "label": "H Value (dB)",
      "type": "number",
      "defaultValue": 32,
      "min": 5,
      "max": 45,
      "step": 1,
      "help": "The protector's rating for high-frequency noise."
    },
    {
      "id": "mValue",
      "label": "M Value (dB)",
      "type": "number",
      "defaultValue": 24,
      "min": 5,
      "max": 45,
      "step": 1,
      "help": "The protector's rating for mid-frequency noise."
    },
    {
      "id": "lValue",
      "label": "L Value (dB)",
      "type": "number",
      "defaultValue": 17,
      "min": 1,
      "max": 45,
      "step": 1,
      "help": "The protector's rating for low-frequency noise."
    },
    {
      "id": "nrr",
      "label": "NRR (dB)",
      "type": "number",
      "defaultValue": 29,
      "min": 5,
      "max": 40,
      "step": 1,
      "help": "The noise reduction rating on the US packaging."
    },
    {
      "id": "nrrWeighting",
      "label": "How the Noise Was Measured",
      "type": "select",
      "defaultValue": "a",
      "options": [
        {
          "value": "a",
          "label": "A-weighted (dBA) — the NRR is reduced by 7 dB first"
        },
        {
          "value": "c",
          "label": "C-weighted (dBC) — the NRR is used as printed"
        }
      ],
      "help": "Whether the level the NRR is deducted from is A- or C-weighted."
    },
    {
      "id": "realWorld",
      "label": "Allow for Real-World Fit",
      "type": "select",
      "defaultValue": "yes",
      "options": [
        {
          "value": "yes",
          "label": "Yes — HSE's 4 dB, or OSHA's 50% for an NRR"
        },
        {
          "value": "no",
          "label": "No — the laboratory rating as printed"
        }
      ],
      "help": "Whether to reduce the rating for how protectors are actually worn."
    }
  ],
  "sources": [
    {
      "label": "BS EN ISO 4869-2 and HSE L108: with the SNR, the A-weighted level under the protector is LC − SNR; with the H, M and L values, the predicted noise level reduction is PNR = M − (H − M)(LC − LA − 2) ÷ 4 where LC − LA is 2 dB or less and PNR = M − (M − L)(LC − LA − 2) ÷ 8 where it is more, and the level at the ear is LA − PNR"
    },
    {
      "label": "HSE L108 (Controlling noise at work): to allow for real-world factors, reduce the protection of any hearing protector by 4 dB; aim for a level at the ear between 70 and 80 dB(A), since protection taking it below 70 dB(A) over-protects and isolates the wearer"
    },
    {
      "label": "29 CFR 1910.95, Appendix B: where the noise is measured A-weighted, subtract 7 dB from the NRR before deducting it, and where it is measured C-weighted, deduct the NRR directly; the OSHA Technical Manual, Section III, Chapter 5, derates the resulting attenuation by 50 per cent to allow for real-world fit"
    }
  ],
  "testCases": [
    {
      "name": "SNR 30 in 100 dB(C), with HSE's 4 dB real-world allowance, leaves 74 dB(A) at the ear",
      "inputs": {
        "method": "snr",
        "laeq": 95,
        "lceq": 100,
        "snr": 30,
        "hValue": 32,
        "mValue": 24,
        "lValue": 17,
        "nrr": 29,
        "nrrWeighting": "a",
        "realWorld": "yes"
      },
      "expected": 74,
      "toleranceDecimalPlaces": 2,
      "unit": "dB(A)",
      "confidence": "medium",
      "steps": [
        {
          "label": "Level the rating is deducted from",
          "value": 100,
          "unit": "dB(C)"
        },
        {
          "label": "Protection assumed",
          "value": 26,
          "unit": "dB"
        },
        {
          "label": "Real-world allowance taken off the rating",
          "value": 4,
          "unit": "dB"
        }
      ],
      "basis": "cited",
      "sourceIndex": 1
    },
    {
      "name": "HML 32/24/17 with LC − LA of 3 dB — low-frequency noise, so M and L set a reduction of 23.1 dB",
      "inputs": {
        "method": "hml",
        "laeq": 95,
        "lceq": 98,
        "snr": 30,
        "hValue": 32,
        "mValue": 24,
        "lValue": 17,
        "nrr": 29,
        "nrrWeighting": "a",
        "realWorld": "yes"
      },
      "expected": 75.875,
      "toleranceDecimalPlaces": 2,
      "unit": "dB(A)",
      "confidence": "medium",
      "steps": [
        {
          "label": "Level the rating is deducted from",
          "value": 95,
          "unit": "dB(A)"
        },
        {
          "label": "Protection assumed",
          "value": 19.125,
          "unit": "dB"
        },
        {
          "label": "Real-world allowance taken off the rating",
          "value": 4,
          "unit": "dB"
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    },
    {
      "name": "HML with LC − LA of 1 dB — high-frequency noise, so H and M set a reduction of 26 dB",
      "inputs": {
        "method": "hml",
        "laeq": 95,
        "lceq": 96,
        "snr": 30,
        "hValue": 32,
        "mValue": 24,
        "lValue": 17,
        "nrr": 29,
        "nrrWeighting": "a",
        "realWorld": "yes"
      },
      "expected": 73,
      "toleranceDecimalPlaces": 2,
      "unit": "dB(A)",
      "confidence": "medium",
      "steps": [
        {
          "label": "Level the rating is deducted from",
          "value": 95,
          "unit": "dB(A)"
        },
        {
          "label": "Protection assumed",
          "value": 22,
          "unit": "dB"
        },
        {
          "label": "Real-world allowance taken off the rating",
          "value": 4,
          "unit": "dB"
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    },
    {
      "name": "NRR 29 against 100 dBA — reduced by 7, then halved — leaves 89 dBA",
      "inputs": {
        "method": "nrr",
        "laeq": 100,
        "lceq": 103,
        "snr": 30,
        "hValue": 32,
        "mValue": 24,
        "lValue": 17,
        "nrr": 29,
        "nrrWeighting": "a",
        "realWorld": "yes"
      },
      "expected": 89,
      "toleranceDecimalPlaces": 2,
      "unit": "dBA",
      "confidence": "medium",
      "steps": [
        {
          "label": "Level the rating is deducted from",
          "value": 100,
          "unit": "dBA"
        },
        {
          "label": "Protection assumed",
          "value": 11,
          "unit": "dB"
        },
        {
          "label": "Real-world allowance taken off the rating",
          "value": 11,
          "unit": "dB"
        }
      ],
      "basis": "cited",
      "sourceIndex": 2
    },
    {
      "name": "NRR 29 against 100 dBC, as printed — the laboratory best case of 71",
      "inputs": {
        "method": "nrr",
        "laeq": 97,
        "lceq": 100,
        "snr": 30,
        "hValue": 32,
        "mValue": 24,
        "lValue": 17,
        "nrr": 29,
        "nrrWeighting": "c",
        "realWorld": "no"
      },
      "expected": 71,
      "toleranceDecimalPlaces": 2,
      "unit": "dBA",
      "confidence": "medium",
      "steps": [
        {
          "label": "Level the rating is deducted from",
          "value": 100,
          "unit": "dBC"
        },
        {
          "label": "Protection assumed",
          "value": 29,
          "unit": "dB"
        },
        {
          "label": "Real-world allowance taken off the rating",
          "value": 0,
          "unit": "dB"
        }
      ],
      "basis": "cited",
      "sourceIndex": 2
    }
  ]
}