  "title": "Concrete Formwork Tie Spacing Calculator",
  "description": "Compute the maximum square-grid spacing for form ties, given the fresh concrete's lateral pressure and the tie's rated capacity.",
  "url": "https://craftquantities.com/calculators/materials-quantities/formwork-tie-spacing-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/formwork-tie-spacing-calculator.json",
  "inputCount": 3,
  "testCaseCount": 3,
  "sourceCount": 1,
  "lastVerified": "2026-09-06",
  "translations": {
    "es-US": "https://craftquantities.com/es/calculators/materials-quantities/formwork-tie-spacing-calculator/"
  },
  "citation": {
    "author": "Craft Quantities",
    "title": "Concrete Formwork Tie Spacing Calculator",
    "version": "1.0.1",
    "sourcesChecked": "2026-09-06",
    "url": "https://craftquantities.com/calculators/materials-quantities/formwork-tie-spacing-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. Concrete Formwork Tie Spacing Calculator. Version 1.0.1. Sources checked 2026-09-06. https://craftquantities.com/calculators/materials-quantities/formwork-tie-spacing-calculator/",
      "apa": "Craft Quantities. (2026). Concrete Formwork Tie Spacing Calculator (Version 1.0.1) [Web calculator]. Retrieved from https://craftquantities.com/calculators/materials-quantities/formwork-tie-spacing-calculator/",
      "harvard": "Craft Quantities (2026) Concrete Formwork Tie Spacing Calculator (Version 1.0.1). Available at: https://craftquantities.com/calculators/materials-quantities/formwork-tie-spacing-calculator/",
      "bibtex": "@misc{craftquantities-calculators-materials-quantities-formwork-tie-spacing-calculator,\n  author       = {{Craft Quantities}},\n  title        = {Concrete Formwork Tie Spacing Calculator},\n  version      = {1.0.1},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/materials-quantities/formwork-tie-spacing-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "lateralPressure",
      "label": "Fresh Concrete Lateral Pressure",
      "type": "number",
      "dimension": "pressure",
      "defaultValue": 50000,
      "min": 10000,
      "max": 450000,
      "step": 1,
      "help": "The design lateral pressure the formwork must resist."
    },
    {
      "id": "tieRatedCapacity",
      "label": "Form Tie Rated Capacity",
      "type": "number",
      "dimension": "force",
      "defaultValue": 20000,
      "min": 5000,
      "max": 300000,
      "step": 1,
      "help": "The tie's manufacturer-rated safe working load."
    },
    {
      "id": "safetyFactor",
      "label": "Safety Factor",
      "type": "number",
      "defaultValue": 2,
      "min": 1.5,
      "max": 3,
      "step": 0.1,
      "help": "The safety factor applied to the tie's rated capacity."
    }
  ],
  "sources": [
    {
      "label": "Each form tie's tributary area = its allowable (safety-factored) load capacity / the fresh concrete lateral pressure; assuming a square grid, spacing = sqrt(tributary area)"
    }
  ],
  "testCases": [
    {
      "name": "50kPa pressure, 20kN tie, SF 2.0",
      "inputs": {
        "lateralPressure": 50000,
        "tieRatedCapacity": 20000,
        "safetyFactor": 2
      },
      "expected": 0.4472,
      "toleranceDecimalPlaces": 2,
      "unit": "m (square grid)",
      "confidence": "medium",
      "steps": [
        {
          "label": "Allowable tie load (after safety factor)",
          "value": 10,
          "unit": "kN"
        },
        {
          "label": "Tributary area per tie",
          "value": 0.2,
          "unit": "m²"
        }
      ],
      "basis": "sole-source",
      "sourceIndex": 0
    },
    {
      "name": "70kPa pressure, 30kN tie, SF 2.5",
      "inputs": {
        "lateralPressure": 70000,
        "tieRatedCapacity": 30000,
        "safetyFactor": 2.5
      },
      "expected": 0.414,
      "toleranceDecimalPlaces": 2,
      "unit": "m (square grid)",
      "confidence": "medium",
      "steps": [
        {
          "label": "Allowable tie load (after safety factor)",
          "value": 12,
          "unit": "kN"
        },
        {
          "label": "Tributary area per tie",
          "value": 0.17142857142857143,
          "unit": "m²"
        }
      ],
      "basis": "sole-source",
      "sourceIndex": 0
    },
    {
      "name": "a 15 m SCC pour at 354 kPa, which the old 150 kPa ceiling cut",
      "inputs": {
        "lateralPressure": 354000,
        "tieRatedCapacity": 20000,
        "safetyFactor": 2
      },
      "expected": 0.168,
      "toleranceDecimalPlaces": 2,
      "unit": "m (square grid)",
      "confidence": "medium",
      "steps": [
        {
          "label": "Allowable tie load (after safety factor)",
          "value": 10,
          "unit": "kN"
        },
        {
          "label": "Tributary area per tie",
          "value": 0.02824858757062147,
          "unit": "m²"
        }
      ],
      "basis": "sole-source",
      "sourceIndex": 0
    }
  ]
}