  "version": "v1",
  "source": "https://craftquantities.com",
  "licence": "CC BY 4.0",
  "licenceUrl": "https://creativecommons.org/licenses/by/4.0/",
  "attribution": "Craft Quantities — craftquantities.com",
  "documentation": "https://craftquantities.com/api/",
  "versioning": "Fields are added, never removed or repurposed, within a version. A breaking change becomes /api/v2/ and v1 keeps being built.",
  "slug": "firestop-caulk-volume-calculator",
  "category": "materials-quantities",
  "title": "Penetration Firestop Caulk Volume Calculator",
  "description": "Calculate the firestop sealant volume needed to seal the annular gap around wall/floor penetrations.",
  "url": "https://craftquantities.com/calculators/materials-quantities/firestop-caulk-volume-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/firestop-caulk-volume-calculator.json",
  "inputCount": 3,
  "testCaseCount": 2,
  "sourceCount": 1,
  "lastVerified": "2026-09-06",
  "translations": {
    "es-US": "https://craftquantities.com/es/calculators/materials-quantities/firestop-caulk-volume-calculator/"
  },
  "citation": {
    "author": "Craft Quantities",
    "title": "Penetration Firestop Caulk Volume Calculator",
    "version": "1.0.1",
    "sourcesChecked": "2026-09-06",
    "url": "https://craftquantities.com/calculators/materials-quantities/firestop-caulk-volume-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. Penetration Firestop Caulk Volume Calculator. Version 1.0.1. Sources checked 2026-09-06. https://craftquantities.com/calculators/materials-quantities/firestop-caulk-volume-calculator/",
      "apa": "Craft Quantities. (2026). Penetration Firestop Caulk Volume Calculator (Version 1.0.1) [Web calculator]. Retrieved from https://craftquantities.com/calculators/materials-quantities/firestop-caulk-volume-calculator/",
      "harvard": "Craft Quantities (2026) Penetration Firestop Caulk Volume Calculator (Version 1.0.1). Available at: https://craftquantities.com/calculators/materials-quantities/firestop-caulk-volume-calculator/",
      "bibtex": "@misc{craftquantities-calculators-materials-quantities-firestop-caulk-volume-calculator,\n  author       = {{Craft Quantities}},\n  title        = {Penetration Firestop Caulk Volume Calculator},\n  version      = {1.0.1},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/materials-quantities/firestop-caulk-volume-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "totalPenetrationPerimeter",
      "label": "Total Penetration Perimeter (Sum of All Openings)",
      "type": "number",
      "dimension": "length",
      "defaultValue": 15,
      "min": 0.01,
      "max": 100,
      "step": 0.5,
      "help": "The combined perimeter length of all penetration openings being firestopped."
    },
    {
      "id": "gapWidth",
      "label": "Annular Gap Width",
      "type": "number",
      "dimension": "length",
      "defaultValue": 0.01,
      "min": 0.003,
      "max": 0.025,
      "step": 0.001,
      "help": "The width of the gap between the penetrating item and the edge of the opening."
    },
    {
      "id": "firestopDepth",
      "label": "Sealant Fill Depth (From the Listed System)",
      "type": "number",
      "dimension": "length",
      "defaultValue": 0.025,
      "min": 0.01,
      "max": 0.2,
      "step": 0.005,
      "help": "The thickness of sealant the tested system calls for at each treated face — not the thickness of the wall or floor."
    }
  ],
  "sources": [
    {
      "label": "Firestop sealant volume = total penetration perimeter × annular gap width × firestop depth, the standard method for estimating a continuous sealant bead around penetration openings"
    }
  ],
  "testCases": [
    {
      "name": "15m perimeter, 10mm gap, 25mm depth",
      "inputs": {
        "totalPenetrationPerimeter": 15,
        "gapWidth": 0.01,
        "firestopDepth": 0.025
      },
      "expected": 3.75,
      "toleranceDecimalPlaces": 2,
      "unit": "L",
      "confidence": "medium",
      "steps": [],
      "basis": "sole-source",
      "sourceIndex": 0
    },
    {
      "name": "22m perimeter, 12mm gap, 30mm depth",
      "inputs": {
        "totalPenetrationPerimeter": 22,
        "gapWidth": 0.012,
        "firestopDepth": 0.03
      },
      "expected": 7.92,
      "toleranceDecimalPlaces": 2,
      "unit": "L",
      "confidence": "medium",
      "steps": [],
      "basis": "sole-source",
      "sourceIndex": 0
    }
  ],
  "usedByAssemblies": [
    {
      "id": "full-rewire",
      "name": "Full house rewire"
    }
  ]
}