  "version": "v1",
  "source": "https://craftquantities.com",
  "licence": "CC BY 4.0",
  "licenceUrl": "https://creativecommons.org/licenses/by/4.0/",
  "attribution": "Craft Quantities — craftquantities.com",
  "documentation": "https://craftquantities.com/api/",
  "versioning": "Fields are added, never removed or repurposed, within a version. A breaking change becomes /api/v2/ and v1 keeps being built.",
  "slug": "fire-rated-gypsum-layer-calculator",
  "category": "materials-quantities",
  "title": "Multi-Layer Fire-Rated (Type X) Gypsum Sheet Calculator",
  "description": "Calculate total Type X gypsum board sheets needed for a multi-layer, both-sides fire-rated wall assembly.",
  "url": "https://craftquantities.com/calculators/materials-quantities/fire-rated-gypsum-layer-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/fire-rated-gypsum-layer-calculator.json",
  "inputCount": 3,
  "testCaseCount": 2,
  "sourceCount": 1,
  "lastVerified": "2026-10-31",
  "translations": {
    "es-US": "https://craftquantities.com/es/calculators/materials-quantities/fire-rated-gypsum-layer-calculator/"
  },
  "citation": {
    "author": "Craft Quantities",
    "title": "Multi-Layer Fire-Rated (Type X) Gypsum Sheet Calculator",
    "version": "1.0.2",
    "sourcesChecked": "2026-10-31",
    "url": "https://craftquantities.com/calculators/materials-quantities/fire-rated-gypsum-layer-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. Multi-Layer Fire-Rated (Type X) Gypsum Sheet Calculator. Version 1.0.2. Sources checked 2026-10-31. https://craftquantities.com/calculators/materials-quantities/fire-rated-gypsum-layer-calculator/",
      "apa": "Craft Quantities. (2026). Multi-Layer Fire-Rated (Type X) Gypsum Sheet Calculator (Version 1.0.2) [Web calculator]. Retrieved from https://craftquantities.com/calculators/materials-quantities/fire-rated-gypsum-layer-calculator/",
      "harvard": "Craft Quantities (2026) Multi-Layer Fire-Rated (Type X) Gypsum Sheet Calculator (Version 1.0.2). Available at: https://craftquantities.com/calculators/materials-quantities/fire-rated-gypsum-layer-calculator/",
      "bibtex": "@misc{craftquantities-calculators-materials-quantities-fire-rated-gypsum-layer-calculator,\n  author       = {{Craft Quantities}},\n  title        = {Multi-Layer Fire-Rated (Type X) Gypsum Sheet Calculator},\n  version      = {1.0.2},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/materials-quantities/fire-rated-gypsum-layer-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "wallArea",
      "label": "Wall Area (One Side)",
      "type": "number",
      "dimension": "area",
      "defaultValue": 20,
      "min": 0.01,
      "max": 300,
      "step": 0.5,
      "help": "The area of one face of the wall being sheeted."
    },
    {
      "id": "sheetArea",
      "label": "Sheet Area",
      "type": "number",
      "dimension": "area",
      "defaultValue": 2.88,
      "min": 0.01,
      "max": 6,
      "step": 0.01,
      "help": "The coverage area of a single Type X gypsum board sheet."
    },
    {
      "id": "layersPerSide",
      "label": "Layers per Side",
      "type": "number",
      "defaultValue": 1,
      "min": 1,
      "max": 4,
      "step": 1,
      "help": "The number of Type X gypsum board layers required on each side of the wall."
    }
  ],
  "sources": [
    {
      "label": "Sheets per side = ceil(wall area ÷ sheet area); total sheets = sheets per side × layers per side × 2 sides. The exact number of Type X layers required for a specific fire-resistance rating (1-hr, 2-hr, etc.) must come from a tested UL or GA fire-rated assembly design, not a general formula"
    }
  ],
  "testCases": [
    {
      "name": "20m² wall, 2.88m² sheet, 1 layer/side",
      "inputs": {
        "wallArea": 20,
        "sheetArea": 2.88,
        "layersPerSide": 1
      },
      "expected": 14,
      "toleranceDecimalPlaces": 0,
      "unit": "sheets",
      "confidence": "medium",
      "steps": [
        {
          "label": "Sheets per side (one layer)",
          "value": 7
        }
      ],
      "basis": "sole-source",
      "sourceIndex": 0
    },
    {
      "name": "30m² wall, 2.88m² sheet, 2 layers/side",
      "inputs": {
        "wallArea": 30,
        "sheetArea": 2.88,
        "layersPerSide": 2
      },
      "expected": 44,
      "toleranceDecimalPlaces": 0,
      "unit": "sheets",
      "confidence": "medium",
      "steps": [
        {
          "label": "Sheets per side (one layer)",
          "value": 11
        }
      ],
      "basis": "sole-source",
      "sourceIndex": 0
    }
  ],
  "usedByAssemblies": [
    {
      "id": "loft-conversion-dormer",
      "name": "Loft conversion with a dormer"
    }
  ]
}