  "version": "v1",
  "source": "https://craftquantities.com",
  "licence": "CC BY 4.0",
  "licenceUrl": "https://creativecommons.org/licenses/by/4.0/",
  "attribution": "Craft Quantities — craftquantities.com",
  "documentation": "https://craftquantities.com/api/",
  "versioning": "Fields are added, never removed or repurposed, within a version. A breaking change becomes /api/v2/ and v1 keeps being built.",
  "slug": "emergency-lighting-spacing-calculator",
  "category": "electrical",
  "title": "Emergency Escape Lighting Spacing Calculator",
  "description": "How many emergency luminaires an escape route needs: the spacing that holds EN 1838's minimum on its centre line, plus one at each point of emphasis.",
  "url": "https://craftquantities.com/calculators/electrical/emergency-lighting-spacing-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/emergency-lighting-spacing-calculator.json",
  "inputCount": 4,
  "testCaseCount": 5,
  "sourceCount": 3,
  "lastVerified": "2026-09-02",
  "translations": {
    "es-US": "https://craftquantities.com/es/calculators/electrical/emergency-lighting-spacing-calculator/"
  },
  "citation": {
    "author": "Craft Quantities",
    "title": "Emergency Escape Lighting Spacing Calculator",
    "version": "1.0.1",
    "sourcesChecked": "2026-09-02",
    "url": "https://craftquantities.com/calculators/electrical/emergency-lighting-spacing-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. Emergency Escape Lighting Spacing Calculator. Version 1.0.1. Sources checked 2026-09-02. https://craftquantities.com/calculators/electrical/emergency-lighting-spacing-calculator/",
      "apa": "Craft Quantities. (2026). Emergency Escape Lighting Spacing Calculator (Version 1.0.1) [Web calculator]. Retrieved from https://craftquantities.com/calculators/electrical/emergency-lighting-spacing-calculator/",
      "harvard": "Craft Quantities (2026) Emergency Escape Lighting Spacing Calculator (Version 1.0.1). Available at: https://craftquantities.com/calculators/electrical/emergency-lighting-spacing-calculator/",
      "bibtex": "@misc{craftquantities-calculators-electrical-emergency-lighting-spacing-calculator,\n  author       = {{Craft Quantities}},\n  title        = {Emergency Escape Lighting Spacing Calculator},\n  version      = {1.0.1},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/electrical/emergency-lighting-spacing-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "routeLength",
      "label": "Escape route length",
      "type": "number",
      "dimension": "length",
      "defaultValue": 30,
      "min": 1,
      "max": 500,
      "step": 1,
      "help": "The length of the escape route this run of luminaires covers."
    },
    {
      "id": "mountingHeight",
      "label": "Mounting height",
      "type": "number",
      "dimension": "length",
      "defaultValue": 2.5,
      "min": 1.8,
      "max": 12,
      "step": 0.1,
      "help": "Height of the luminaire above the floor."
    },
    {
      "id": "spacingRatio",
      "label": "Spacing-to-height ratio at 1 lux",
      "type": "number",
      "defaultValue": 4,
      "min": 1,
      "max": 12,
      "step": 0.1,
      "help": "From the luminaire's own spacing table — how many times its mounting height it may be spaced."
    },
    {
      "id": "pointsOfEmphasis",
      "label": "Points of emphasis on this route",
      "type": "number",
      "defaultValue": 3,
      "min": 0,
      "max": 50,
      "step": 1,
      "help": "Exits, stair flights, changes of direction and level, call points and firefighting equipment."
    }
  ],
  "sources": [
    {
      "label": "EN 1838 / BS 5266-7, Lighting applications — emergency lighting: escape routes up to 2 m wide require a minimum of 1 lux on the centre line, with uniformity along that line no worse than 40:1"
    },
    {
      "label": "BS 5266-1, Code of practice for the emergency escape lighting of premises: a luminaire is required at each exit door, at each stair flight so every flight receives direct light, at every change of direction and change of level, at intersections of corridors, outside each final exit, and at fire alarm call points and firefighting equipment — conventionally within 2 m horizontally of each"
    },
    {
      "label": "Spacing is taken as the mounting height multiplied by the luminaire's published spacing-to-height ratio for the target illuminance; that ratio comes from the manufacturer's photometric data and is specific to the fitting"
    }
  ],
  "testCases": [
    {
      "name": "30 m corridor, 2.5 m mounting, ratio 4, three points of emphasis",
      "inputs": {
        "routeLength": 30,
        "mountingHeight": 2.5,
        "spacingRatio": 4,
        "pointsOfEmphasis": 3
      },
      "expected": 7,
      "toleranceDecimalPlaces": 0,
      "unit": "luminaires",
      "confidence": "medium",
      "steps": [
        {
          "label": "Maximum spacing at this height and ratio",
          "value": 10,
          "unit": "m"
        },
        {
          "label": "Actual spacing once the run is divided evenly",
          "value": 10,
          "unit": "m"
        },
        {
          "label": "Luminaires from spacing alone",
          "value": 4,
          "unit": "fittings"
        },
        {
          "label": "Added for points of emphasis",
          "value": 3,
          "unit": "fittings"
        }
      ],
      "basis": "ambiguous"
    },
    {
      "name": "A shorter route still needs both ends",
      "inputs": {
        "routeLength": 8,
        "mountingHeight": 2.5,
        "spacingRatio": 4,
        "pointsOfEmphasis": 0
      },
      "expected": 2,
      "toleranceDecimalPlaces": 0,
      "unit": "luminaires",
      "confidence": "medium",
      "steps": [
        {
          "label": "Maximum spacing at this height and ratio",
          "value": 10,
          "unit": "m"
        },
        {
          "label": "Actual spacing once the run is divided evenly",
          "value": 8,
          "unit": "m"
        },
        {
          "label": "Luminaires from spacing alone",
          "value": 2,
          "unit": "fittings"
        },
        {
          "label": "Added for points of emphasis",
          "value": 0,
          "unit": "fittings"
        }
      ],
      "basis": "ambiguous"
    },
    {
      "name": "A lower spacing ratio tightens the run",
      "inputs": {
        "routeLength": 30,
        "mountingHeight": 2.5,
        "spacingRatio": 2,
        "pointsOfEmphasis": 0
      },
      "expected": 7,
      "toleranceDecimalPlaces": 0,
      "unit": "luminaires",
      "confidence": "medium",
      "steps": [
        {
          "label": "Maximum spacing at this height and ratio",
          "value": 5,
          "unit": "m"
        },
        {
          "label": "Actual spacing once the run is divided evenly",
          "value": 5,
          "unit": "m"
        },
        {
          "label": "Luminaires from spacing alone",
          "value": 7,
          "unit": "fittings"
        },
        {
          "label": "Added for points of emphasis",
          "value": 0,
          "unit": "fittings"
        }
      ],
      "basis": "ambiguous"
    },
    {
      "name": "Mounting height drives spacing too",
      "inputs": {
        "routeLength": 30,
        "mountingHeight": 5,
        "spacingRatio": 4,
        "pointsOfEmphasis": 0
      },
      "expected": 3,
      "toleranceDecimalPlaces": 0,
      "unit": "luminaires",
      "confidence": "medium",
      "steps": [
        {
          "label": "Maximum spacing at this height and ratio",
          "value": 20,
          "unit": "m"
        },
        {
          "label": "Actual spacing once the run is divided evenly",
          "value": 15,
          "unit": "m"
        },
        {
          "label": "Luminaires from spacing alone",
          "value": 3,
          "unit": "fittings"
        },
        {
          "label": "Added for points of emphasis",
          "value": 0,
          "unit": "fittings"
        }
      ],
      "basis": "ambiguous"
    },
    {
      "name": "Points of emphasis add rather than absorb",
      "inputs": {
        "routeLength": 30,
        "mountingHeight": 2.5,
        "spacingRatio": 4,
        "pointsOfEmphasis": 6
      },
      "expected": 10,
      "toleranceDecimalPlaces": 0,
      "unit": "luminaires",
      "confidence": "medium",
      "steps": [
        {
          "label": "Maximum spacing at this height and ratio",
          "value": 10,
          "unit": "m"
        },
        {
          "label": "Actual spacing once the run is divided evenly",
          "value": 10,
          "unit": "m"
        },
        {
          "label": "Luminaires from spacing alone",
          "value": 4,
          "unit": "fittings"
        },
        {
          "label": "Added for points of emphasis",
          "value": 6,
          "unit": "fittings"
        }
      ],
      "basis": "ambiguous"
    }
  ]
}