  "version": "v1",
  "source": "https://craftquantities.com",
  "licence": "CC BY 4.0",
  "licenceUrl": "https://creativecommons.org/licenses/by/4.0/",
  "attribution": "Craft Quantities — craftquantities.com",
  "documentation": "https://craftquantities.com/api/",
  "versioning": "Fields are added, never removed or repurposed, within a version. A breaking change becomes /api/v2/ and v1 keeps being built.",
  "slug": "duct-design-friction-rate-calculator",
  "category": "plumbing-hvac",
  "title": "Duct Design Friction Rate Calculator (ACCA Manual D)",
  "description": "The friction rate to size ducts at under ACCA Manual D: blower static pressure less the component losses, spread over the longest supply and return runs.",
  "url": "https://craftquantities.com/calculators/plumbing-hvac/duct-design-friction-rate-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/duct-design-friction-rate-calculator.json",
  "inputCount": 8,
  "testCaseCount": 3,
  "sourceCount": 2,
  "lastVerified": "2026-09-22",
  "citation": {
    "author": "Craft Quantities",
    "title": "Duct Design Friction Rate Calculator (ACCA Manual D)",
    "version": "1.0.0",
    "sourcesChecked": "2026-09-22",
    "url": "https://craftquantities.com/calculators/plumbing-hvac/duct-design-friction-rate-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. Duct Design Friction Rate Calculator (ACCA Manual D). Version 1.0.0. Sources checked 2026-09-22. https://craftquantities.com/calculators/plumbing-hvac/duct-design-friction-rate-calculator/",
      "apa": "Craft Quantities. (2026). Duct Design Friction Rate Calculator (ACCA Manual D) (Version 1.0.0) [Web calculator]. Retrieved from https://craftquantities.com/calculators/plumbing-hvac/duct-design-friction-rate-calculator/",
      "harvard": "Craft Quantities (2026) Duct Design Friction Rate Calculator (ACCA Manual D) (Version 1.0.0). Available at: https://craftquantities.com/calculators/plumbing-hvac/duct-design-friction-rate-calculator/",
      "bibtex": "@misc{craftquantities-calculators-plumbing-hvac-duct-design-friction-rate-calculator,\n  author       = {{Craft Quantities}},\n  title        = {Duct Design Friction Rate Calculator (ACCA Manual D)},\n  version      = {1.0.0},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/plumbing-hvac/duct-design-friction-rate-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "blowerEsp",
      "label": "Blower External Static Pressure at the Design Airflow",
      "type": "number",
      "dimension": "pressure",
      "defaultValue": 124.54445415,
      "min": 10,
      "max": 750,
      "step": 1,
      "help": "From the manufacturer's blower table, at the airflow the system is designed to move."
    },
    {
      "id": "coilDrop",
      "label": "Cooling Coil Pressure Drop",
      "type": "number",
      "dimension": "pressure",
      "defaultValue": 49.81778166000001,
      "min": 0,
      "max": 500,
      "step": 0.5,
      "help": "From the component maker's data at the design airflow."
    },
    {
      "id": "filterDrop",
      "label": "Filter Pressure Drop",
      "type": "number",
      "dimension": "pressure",
      "defaultValue": 24.908890830000004,
      "min": 0,
      "max": 500,
      "step": 0.5,
      "help": "From the component maker's data at the design airflow."
    },
    {
      "id": "supplyOutletDrop",
      "label": "Supply Outlet Pressure Drop",
      "type": "number",
      "dimension": "pressure",
      "defaultValue": 7.472667249000001,
      "min": 0,
      "max": 500,
      "step": 0.5,
      "help": "From the component maker's data at the design airflow."
    },
    {
      "id": "returnGrilleDrop",
      "label": "Return Grille Pressure Drop",
      "type": "number",
      "dimension": "pressure",
      "defaultValue": 7.472667249000001,
      "min": 0,
      "max": 500,
      "step": 0.5,
      "help": "From the component maker's data at the design airflow."
    },
    {
      "id": "otherDrop",
      "label": "Other Components (dampers, humidifier; 0 if none)",
      "type": "number",
      "dimension": "pressure",
      "defaultValue": 0,
      "min": 0,
      "max": 500,
      "step": 0.5,
      "help": "From the component maker's data at the design airflow."
    },
    {
      "id": "supplyLength",
      "label": "Total Effective Length of the Longest Supply Run",
      "type": "number",
      "dimension": "length",
      "defaultValue": 76.2,
      "min": 1,
      "max": 2000,
      "step": 0.5,
      "help": "The measured run from the plenum to the farthest outlet plus the equivalent length of every fitting on it."
    },
    {
      "id": "returnLength",
      "label": "Total Effective Length of the Longest Return Run",
      "type": "number",
      "dimension": "length",
      "defaultValue": 30.48,
      "min": 0,
      "max": 2000,
      "step": 0.5,
      "help": "The same for the longest return path, from the most remote grille back to the unit."
    }
  ],
  "sources": [
    {
      "label": "ACCA Manual D, Residential Duct Systems — the friction rate worksheet: available static pressure = the blower's external static pressure at the design airflow − the component pressure drops; friction rate = available static pressure × 100 ÷ total effective length"
    },
    {
      "label": "Total effective length = the longest supply run plus the longest return run, each with the equivalent length of its fittings"
    }
  ],
  "testCases": [
    {
      "name": "0.5 in. w.g. blower, 0.36 in. of components, 350 ft of effective length",
      "inputs": {
        "blowerEsp": 124.54445415,
        "coilDrop": 49.81778166000001,
        "filterDrop": 24.908890830000004,
        "supplyOutletDrop": 7.472667249000001,
        "returnGrilleDrop": 7.472667249000001,
        "otherDrop": 0,
        "supplyLength": 76.2,
        "returnLength": 30.48
      },
      "expected": 0.326888,
      "toleranceDecimalPlaces": 5,
      "unit": "Pa/m",
      "confidence": "high",
      "steps": [
        {
          "label": "The components' pressure drops together",
          "value": 89.672006988,
          "unit": "Pa"
        },
        {
          "label": "Available static pressure for the ducts",
          "value": 34.872447162,
          "unit": "Pa"
        },
        {
          "label": "Total effective length, supply plus return",
          "value": 106.68,
          "unit": "m"
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    },
    {
      "name": "0.8 in. w.g. blower, 0.46 in. of components, 300 ft",
      "inputs": {
        "blowerEsp": 199.27112664000003,
        "coilDrop": 62.272227075,
        "filterDrop": 37.363336245,
        "supplyOutletDrop": 7.472667249000001,
        "returnGrilleDrop": 7.472667249000001,
        "otherDrop": 0,
        "supplyLength": 60.96,
        "returnLength": 30.48
      },
      "expected": 0.926184,
      "toleranceDecimalPlaces": 5,
      "unit": "Pa/m",
      "confidence": "high",
      "steps": [
        {
          "label": "The components' pressure drops together",
          "value": 114.580897818,
          "unit": "Pa"
        },
        {
          "label": "Available static pressure for the ducts",
          "value": 84.69022882200004,
          "unit": "Pa"
        },
        {
          "label": "Total effective length, supply plus return",
          "value": 91.44,
          "unit": "m"
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    },
    {
      "name": "Components that use up the blower leave nothing for the ducts",
      "inputs": {
        "blowerEsp": 74.72667249,
        "coilDrop": 49.81778166000001,
        "filterDrop": 37.363336245,
        "supplyOutletDrop": 7.472667249000001,
        "returnGrilleDrop": 7.472667249000001,
        "otherDrop": 0,
        "supplyLength": 76.2,
        "returnLength": 30.48
      },
      "expected": 0,
      "toleranceDecimalPlaces": 5,
      "unit": "Pa/m",
      "confidence": "high",
      "steps": [
        {
          "label": "The components' pressure drops together",
          "value": 102.126452403,
          "unit": "Pa"
        },
        {
          "label": "Available static pressure for the ducts",
          "value": -27.399779913000003,
          "unit": "Pa"
        },
        {
          "label": "Total effective length, supply plus return",
          "value": 106.68,
          "unit": "m"
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    }
  ]
}