  "version": "v1",
  "source": "https://craftquantities.com",
  "licence": "CC BY 4.0",
  "licenceUrl": "https://creativecommons.org/licenses/by/4.0/",
  "attribution": "Craft Quantities — craftquantities.com",
  "documentation": "https://craftquantities.com/api/",
  "versioning": "Fields are added, never removed or repurposed, within a version. A breaking change becomes /api/v2/ and v1 keeps being built.",
  "slug": "dehumidifier-pulldown-calculator",
  "category": "plumbing-hvac",
  "title": "Dehumidifier Water Removal Calculator",
  "description": "The water held in a room's air between its current and target humidity, in gallons or litres, and the pull-down time at your unit's real extraction rate.",
  "url": "https://craftquantities.com/calculators/plumbing-hvac/dehumidifier-pulldown-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/dehumidifier-pulldown-calculator.json",
  "inputCount": 7,
  "testCaseCount": 3,
  "sourceCount": 4,
  "lastVerified": "2026-09-02",
  "citation": {
    "author": "Craft Quantities",
    "title": "Dehumidifier Water Removal Calculator",
    "version": "1.0.1",
    "sourcesChecked": "2026-09-02",
    "url": "https://craftquantities.com/calculators/plumbing-hvac/dehumidifier-pulldown-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. Dehumidifier Water Removal Calculator. Version 1.0.1. Sources checked 2026-09-02. https://craftquantities.com/calculators/plumbing-hvac/dehumidifier-pulldown-calculator/",
      "apa": "Craft Quantities. (2026). Dehumidifier Water Removal Calculator (Version 1.0.1) [Web calculator]. Retrieved from https://craftquantities.com/calculators/plumbing-hvac/dehumidifier-pulldown-calculator/",
      "harvard": "Craft Quantities (2026) Dehumidifier Water Removal Calculator (Version 1.0.1). Available at: https://craftquantities.com/calculators/plumbing-hvac/dehumidifier-pulldown-calculator/",
      "bibtex": "@misc{craftquantities-calculators-plumbing-hvac-dehumidifier-pulldown-calculator,\n  author       = {{Craft Quantities}},\n  title        = {Dehumidifier Water Removal Calculator},\n  version      = {1.0.1},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/plumbing-hvac/dehumidifier-pulldown-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "area",
      "label": "Floor area",
      "type": "number",
      "dimension": "area",
      "defaultValue": 40,
      "min": 0.01,
      "max": 2000,
      "help": "The floor area of the space being dried."
    },
    {
      "id": "height",
      "label": "Ceiling height",
      "type": "number",
      "dimension": "length",
      "defaultValue": 2.5,
      "min": 0.01,
      "max": 10,
      "help": "Average ceiling height — area × height is the air volume that holds the water."
    },
    {
      "id": "temp",
      "label": "Room temperature",
      "type": "number",
      "dimension": "temperature",
      "defaultValue": 20,
      "min": 5,
      "max": 35,
      "help": "Air temperature in the space. Warmer air holds more water at the same relative humidity."
    },
    {
      "id": "rhStart",
      "label": "Current relative humidity (%)",
      "type": "number",
      "defaultValue": 70,
      "min": 20,
      "max": 100,
      "help": "What the hygrometer reads now, in %."
    },
    {
      "id": "rhTarget",
      "label": "Target relative humidity (%)",
      "type": "number",
      "defaultValue": 55,
      "min": 20,
      "max": 90,
      "help": "Where you want to hold the space — 50–55% is the usual comfort and mould-control band."
    },
    {
      "id": "ratedCapacity",
      "label": "Dehumidifier rated capacity (L/day)",
      "type": "number",
      "defaultValue": 20,
      "min": 0.5,
      "max": 100,
      "help": "The litres-per-day figure on the unit's plate or box."
    },
    {
      "id": "deratePercent",
      "label": "Real-conditions extraction (% of rated)",
      "type": "number",
      "defaultValue": 70,
      "min": 10,
      "max": 100,
      "help": "How much of the rated capacity your room's conditions actually deliver."
    }
  ],
  "sources": [
    {
      "label": "Magnus saturation-vapour-pressure approximation, e_s = 6.112·exp(17.62·T/(243.12+T)) hPa — WMO-recommended coefficients"
    },
    {
      "label": "Vapour mass from the ideal gas law on the vapour's own partial pressure, m = e·V/(R_v·T), with R_v = 461.5 J/(kg·K) — so no fixed air density enters and the figure stays exact across the whole temperature range"
    },
    {
      "label": "Humidity ratio W = 0.622·e/(P−e) at standard sea-level pressure — psychrometric relations per ASHRAE Handbook — Fundamentals"
    },
    {
      "label": "Rated dehumidifier capacity is defined at a standard test condition; the US DOE test procedure (10 CFR 430) moved from 80°F/60% RH to 65°F/60% RH, roughly halving printed ratings for the same hardware — the unit's own documentation governs its real extraction"
    }
  ],
  "testCases": [
    {
      "name": "40 m² room, 2.5 m ceiling, 20 °C, 70% → 55%",
      "inputs": {
        "area": 40,
        "height": 2.5,
        "temp": 20,
        "rhStart": 70,
        "rhTarget": 55,
        "ratedCapacity": 20,
        "deratePercent": 70
      },
      "expected": 0.2586,
      "toleranceDecimalPlaces": 2,
      "unit": "L",
      "confidence": "medium",
      "steps": [
        {
          "label": "Room air volume",
          "value": 100,
          "unit": "m³"
        },
        {
          "label": "Water in the air now",
          "value": 1.2069130043678546,
          "unit": "L"
        },
        {
          "label": "Water in the air at the target",
          "value": 0.9482887891461719,
          "unit": "L"
        },
        {
          "label": "Pull-down time at derated capacity",
          "value": 0.44335579752288473,
          "unit": "hours"
        },
        {
          "label": "Effective extraction rate",
          "value": 14,
          "unit": "L/day"
        }
      ],
      "basis": "ambiguous"
    },
    {
      "name": "Cool 300 m³ basement, 80% → 50%",
      "inputs": {
        "area": 100,
        "height": 3,
        "temp": 15,
        "rhStart": 80,
        "rhTarget": 50,
        "ratedCapacity": 12,
        "deratePercent": 50
      },
      "expected": 1.1532,
      "toleranceDecimalPlaces": 1,
      "unit": "L",
      "confidence": "medium",
      "steps": [
        {
          "label": "Room air volume",
          "value": 300,
          "unit": "m³"
        },
        {
          "label": "Water in the air now",
          "value": 3.071119895114769,
          "unit": "L"
        },
        {
          "label": "Water in the air at the target",
          "value": 1.9194499344467304,
          "unit": "L"
        },
        {
          "label": "Pull-down time at derated capacity",
          "value": 4.606679842672154,
          "unit": "hours"
        },
        {
          "label": "Effective extraction rate",
          "value": 6,
          "unit": "L/day"
        }
      ],
      "basis": "ambiguous"
    },
    {
      "name": "Target above current humidity: nothing to remove",
      "inputs": {
        "area": 40,
        "height": 2.5,
        "temp": 20,
        "rhStart": 50,
        "rhTarget": 60,
        "ratedCapacity": 20,
        "deratePercent": 70
      },
      "expected": 0,
      "toleranceDecimalPlaces": 0,
      "unit": "L",
      "confidence": "low",
      "steps": [
        {
          "label": "Room air volume",
          "value": 100,
          "unit": "m³"
        },
        {
          "label": "Water in the air now",
          "value": 0.8620807174056107,
          "unit": "L"
        },
        {
          "label": "Water in the air at the target",
          "value": 1.0344968608867329,
          "unit": "L"
        },
        {
          "label": "Pull-down time at derated capacity",
          "value": 0,
          "unit": "hours"
        },
        {
          "label": "Effective extraction rate",
          "value": 14,
          "unit": "L/day"
        }
      ],
      "basis": "ambiguous"
    }
  ]
}