  "version": "v1",
  "source": "https://craftquantities.com",
  "licence": "CC BY 4.0",
  "licenceUrl": "https://creativecommons.org/licenses/by/4.0/",
  "attribution": "Craft Quantities — craftquantities.com",
  "documentation": "https://craftquantities.com/api/",
  "versioning": "Fields are added, never removed or repurposed, within a version. A breaking change becomes /api/v2/ and v1 keeps being built.",
  "slug": "curtain-wall-condensation-checker",
  "category": "materials-quantities",
  "title": "Curtain Wall Spandrel Condensation Risk Checker",
  "description": "Check whether a curtain wall spandrel's interior glass surface temperature stays above the dew point under winter design conditions.",
  "url": "https://craftquantities.com/calculators/materials-quantities/curtain-wall-condensation-checker/",
  "json": "https://craftquantities.com/api/v1/calculators/curtain-wall-condensation-checker.json",
  "inputCount": 5,
  "testCaseCount": 2,
  "sourceCount": 1,
  "lastVerified": "2026-09-06",
  "translations": {
    "es-US": "https://craftquantities.com/es/calculators/materials-quantities/curtain-wall-condensation-checker/"
  },
  "citation": {
    "author": "Craft Quantities",
    "title": "Curtain Wall Spandrel Condensation Risk Checker",
    "version": "1.1.1",
    "sourcesChecked": "2026-09-06",
    "url": "https://craftquantities.com/calculators/materials-quantities/curtain-wall-condensation-checker/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. Curtain Wall Spandrel Condensation Risk Checker. Version 1.1.1. Sources checked 2026-09-06. https://craftquantities.com/calculators/materials-quantities/curtain-wall-condensation-checker/",
      "apa": "Craft Quantities. (2026). Curtain Wall Spandrel Condensation Risk Checker (Version 1.1.1) [Web calculator]. Retrieved from https://craftquantities.com/calculators/materials-quantities/curtain-wall-condensation-checker/",
      "harvard": "Craft Quantities (2026) Curtain Wall Spandrel Condensation Risk Checker (Version 1.1.1). Available at: https://craftquantities.com/calculators/materials-quantities/curtain-wall-condensation-checker/",
      "bibtex": "@misc{craftquantities-calculators-materials-quantities-curtain-wall-condensation-checker,\n  author       = {{Craft Quantities}},\n  title        = {Curtain Wall Spandrel Condensation Risk Checker},\n  version      = {1.1.1},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/materials-quantities/curtain-wall-condensation-checker/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "interiorTemp",
      "label": "Interior Design Temperature",
      "type": "number",
      "dimension": "temperature",
      "defaultValue": 21,
      "min": 15,
      "max": 25,
      "step": 0.5,
      "help": "The interior air design temperature used for the winter condensation check."
    },
    {
      "id": "exteriorTemp",
      "label": "Exterior Winter Design Temperature",
      "type": "number",
      "dimension": "temperature",
      "defaultValue": -10,
      "min": -40,
      "max": 5,
      "step": 0.5,
      "help": "The exterior winter design temperature for the project location, typically a 97.5% or 99% design condition."
    },
    {
      "id": "uFactor",
      "label": "Assembly U-Factor (W/m²K)",
      "type": "number",
      "defaultValue": 1.8,
      "min": 0.8,
      "max": 4,
      "step": 0.1,
      "help": "The overall U-factor of the spandrel/vision glass assembly being checked."
    },
    {
      "id": "interiorFilmCoefficient",
      "label": "Interior Film Coefficient (W/m²K, commonly 8)",
      "type": "number",
      "defaultValue": 8,
      "min": 5,
      "max": 12,
      "step": 0.5,
      "help": "The interior air film coefficient, commonly taken as 8 W/m²K per standard convention."
    },
    {
      "id": "dewPoint",
      "label": "Interior Air Dew Point",
      "type": "number",
      "dimension": "temperature",
      "defaultValue": 10,
      "min": -5,
      "max": 20,
      "step": 0.5,
      "help": "The dew point of the interior air, based on its temperature and relative humidity."
    }
  ],
  "sources": [
    {
      "label": "Steady-state condensation risk check per AAMA 1503/NFRC 500 methodology: interior surface temperature Ts = Ti − U×(Ti−To)/hi, where Ti/To are interior/exterior design temperatures, U is the assembly's overall U-factor, and hi is the interior air film coefficient (commonly 8 W/m²K); condensation risk exists if Ts falls below the interior air's dew point"
    }
  ],
  "testCases": [
    {
      "name": "Ti=21, To=-10, U=1.8, hi=8, dew=10 (pass)",
      "inputs": {
        "interiorTemp": 21,
        "exteriorTemp": -10,
        "uFactor": 1.8,
        "interiorFilmCoefficient": 8,
        "dewPoint": 10
      },
      "expected": 14.03,
      "toleranceDecimalPlaces": 1,
      "unit": "°C",
      "confidence": "medium",
      "steps": [
        {
          "label": "Interior air dew point",
          "value": 10,
          "unit": "°C"
        }
      ],
      "basis": "sole-source",
      "sourceIndex": 0
    },
    {
      "name": "Ti=21, To=-20, U=2.5, hi=8, dew=12 (fail)",
      "inputs": {
        "interiorTemp": 21,
        "exteriorTemp": -20,
        "uFactor": 2.5,
        "interiorFilmCoefficient": 8,
        "dewPoint": 12
      },
      "expected": 8.19,
      "toleranceDecimalPlaces": 1,
      "unit": "°C",
      "confidence": "medium",
      "steps": [
        {
          "label": "Interior air dew point",
          "value": 12,
          "unit": "°C"
        }
      ],
      "basis": "sole-source",
      "sourceIndex": 0
    }
  ]
}