  "version": "v1",
  "source": "https://craftquantities.com",
  "licence": "CC BY 4.0",
  "licenceUrl": "https://creativecommons.org/licenses/by/4.0/",
  "attribution": "Craft Quantities — craftquantities.com",
  "documentation": "https://craftquantities.com/api/",
  "versioning": "Fields are added, never removed or repurposed, within a version. A breaking change becomes /api/v2/ and v1 keeps being built.",
  "slug": "crawl-space-vent-calculator",
  "category": "materials-quantities",
  "title": "Crawl Space and Subfloor Vent Calculator",
  "description": "The net vent area a vented crawl space or suspended ground floor needs by the IRC or Approved Document C, and how many vents of a rated size that takes.",
  "url": "https://craftquantities.com/calculators/materials-quantities/crawl-space-vent-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/crawl-space-vent-calculator.json",
  "inputCount": 5,
  "testCaseCount": 3,
  "sourceCount": 4,
  "lastVerified": "2026-09-25",
  "citation": {
    "author": "Craft Quantities",
    "title": "Crawl Space and Subfloor Vent Calculator",
    "version": "1.0.0",
    "sourcesChecked": "2026-09-25",
    "url": "https://craftquantities.com/calculators/materials-quantities/crawl-space-vent-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. Crawl Space and Subfloor Vent Calculator. Version 1.0.0. Sources checked 2026-09-25. https://craftquantities.com/calculators/materials-quantities/crawl-space-vent-calculator/",
      "apa": "Craft Quantities. (2026). Crawl Space and Subfloor Vent Calculator (Version 1.0.0) [Web calculator]. Retrieved from https://craftquantities.com/calculators/materials-quantities/crawl-space-vent-calculator/",
      "harvard": "Craft Quantities (2026) Crawl Space and Subfloor Vent Calculator (Version 1.0.0). Available at: https://craftquantities.com/calculators/materials-quantities/crawl-space-vent-calculator/",
      "bibtex": "@misc{craftquantities-calculators-materials-quantities-crawl-space-vent-calculator,\n  author       = {{Craft Quantities}},\n  title        = {Crawl Space and Subfloor Vent Calculator},\n  version      = {1.0.0},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/materials-quantities/crawl-space-vent-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "rule",
      "label": "Rule",
      "type": "select",
      "defaultValue": "irc",
      "options": [
        {
          "value": "irc",
          "label": "IRC R408.2 — open ground (United States)"
        },
        {
          "value": "ircRetarder",
          "label": "IRC R408.2 exception — ground under a Class I vapor retarder"
        },
        {
          "value": "adc",
          "label": "Approved Document C — suspended ground floor (England)"
        }
      ],
      "help": "The US rule for a vented crawl space, with or without a ground cover, or the English rule for a suspended floor."
    },
    {
      "id": "length",
      "label": "Under-floor space length",
      "type": "number",
      "dimension": "length",
      "defaultValue": 12,
      "min": 1,
      "max": 200,
      "step": 0.1,
      "help": "Outside to outside of the foundation walls around the space."
    },
    {
      "id": "width",
      "label": "Under-floor space width",
      "type": "number",
      "dimension": "length",
      "defaultValue": 9,
      "min": 1,
      "max": 200,
      "step": 0.1,
      "help": "The other plan dimension."
    },
    {
      "id": "vent",
      "label": "Vent",
      "type": "select",
      "defaultValue": "vent1",
      "options": [
        {
          "value": "vent1",
          "label": "16 × 8 in foundation vent, 45 sq in (slider)"
        },
        {
          "value": "vent2",
          "label": "16 × 8 in foundation vent, 64 sq in (folding damper)"
        },
        {
          "value": "custom",
          "label": "Another vent (enter its rating)"
        }
      ],
      "optionsBySystem": {
        "imperial": [
          {
            "value": "vent1",
            "label": "16 × 8 in foundation vent, 45 sq in (slider)"
          },
          {
            "value": "vent2",
            "label": "16 × 8 in foundation vent, 64 sq in (folding damper)"
          },
          {
            "value": "custom",
            "label": "Another vent (enter its rating)"
          }
        ],
        "metric": [
          {
            "value": "vent1",
            "label": "215 × 69 mm plastic airbrick, 6,170 mm²"
          },
          {
            "value": "vent2",
            "label": "Periscope ventilator with airbrick, 7,750 mm²"
          },
          {
            "value": "custom",
            "label": "Another vent (enter its rating)"
          }
        ]
      },
      "help": "Vents as each market sells them; the count divides by the rating printed on the vent."
    },
    {
      "id": "ventArea",
      "label": "Net free area of one vent",
      "type": "number",
      "dimension": "area",
      "defaultValue": 0.029032199999999998,
      "min": 0.0005,
      "max": 0.5,
      "step": 0.0001,
      "help": "From the vent's label or datasheet."
    }
  ],
  "sources": [
    {
      "label": "International Code Council, 2021 International Residential Code, R408.2: net ventilation opening area at least 1 sq ft (0.0929 m²) for each 150 sq ft (14 m²) of under-floor area, one opening within 3 ft (915 mm) of each external corner; exception 1, 1/1,500 of the area where the ground is covered with a Class I vapor retarder; exception 2, cross ventilation in place of the corner rule with that retarder",
      "url": "https://codes.iccsafe.org/content/IRC2021P2/chapter-4-foundations"
    },
    {
      "label": "The same code, R408.3 unvented crawl spaces: a continuous Class I vapor retarder and, among the options, continuous exhaust or a conditioned supply of 1 cfm (0.47 L/s) for each 50 sq ft (4.7 m²) of floor area",
      "url": "https://codes.iccsafe.org/content/IRC2021P2/chapter-4-foundations"
    },
    {
      "label": "HM Government, Approved Document C (2004 edition incorporating 2010 and 2013 amendments), 4.14(b) and 4.19(b): openings in two opposing external walls of not less than 1,500 mm² per metre run of external wall or 500 mm² per m² of floor area, whichever gives the greater; a void of at least 75 mm to wall-plates and 150 mm to the floor; ducts at least 100 mm in diameter",
      "url": "https://assets.publishing.service.gov.uk/media/5a8192a0e5274a2e8ab54b5f/BR_PDF_AD_C_2013.pdf"
    },
    {
      "label": "Vent ratings: Gibraltar Building Products ventilation catalogue (2022), 16 × 8 in foundation vents at 45 sq in (models ALSL, PLSLBL) and 64 sq in (PLDPBL) net free area; Timloc 1201 airbrick datasheet (2025), 6,170 mm² equivalent area; Rytons Periscope PUFV datasheet (2010), 7,750 mm² with airbrick fitted",
      "url": "https://gibraltarbuildingproducts.com/wp-content/resources/catalog/GBAD_Ventilation+Catalog_2022_WEB_3-22-23.pdf"
    }
  ],
  "testCases": [
    {
      "name": "IRC open ground: 1,200 sq ft is 8 sq ft of vent, 1,152 sq in — 26 vents at 45 sq in",
      "inputs": {
        "rule": "irc",
        "length": 12.192,
        "width": 9.144,
        "vent": "vent1",
        "ventArea": 0.029032199999999998
      },
      "expected": 1152,
      "toleranceDecimalPlaces": 1,
      "unit": "in²",
      "confidence": "high",
      "steps": [
        {
          "label": "The same area",
          "value": 8,
          "unit": "sq ft"
        },
        {
          "label": "Vents at the chosen rating",
          "value": 26,
          "unit": "vents"
        },
        {
          "label": "Under-floor area",
          "value": 1200,
          "unit": "sq ft"
        },
        {
          "label": "Unvented instead: continuous exhaust (R408.3)",
          "value": 24,
          "unit": "cfm"
        },
        {
          "label": "Least vents by position (one near each corner)",
          "value": 4,
          "unit": "vents"
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    },
    {
      "name": "IRC with a Class I vapor retarder: 1,200 sq ft at 1/1,500 is 0.8 sq ft, 115.2 sq in",
      "inputs": {
        "rule": "ircRetarder",
        "length": 12.192,
        "width": 9.144,
        "vent": "vent2",
        "ventArea": 0.029032199999999998
      },
      "expected": 115.2,
      "toleranceDecimalPlaces": 1,
      "unit": "in²",
      "confidence": "high",
      "steps": [
        {
          "label": "The same area",
          "value": 0.8,
          "unit": "sq ft"
        },
        {
          "label": "Vents at the chosen rating",
          "value": 2,
          "unit": "vents"
        },
        {
          "label": "Under-floor area",
          "value": 1200,
          "unit": "sq ft"
        },
        {
          "label": "Unvented instead: continuous exhaust (R408.3)",
          "value": 24,
          "unit": "cfm"
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    },
    {
      "name": "Approved Document C: 12 × 9 m, perimeter 42 m — 63,000 mm² by the wall run beats 54,000 by the floor; 97.65 sq in",
      "inputs": {
        "rule": "adc",
        "length": 12,
        "width": 9,
        "vent": "custom",
        "ventArea": 0.00617
      },
      "expected": 97.6502,
      "toleranceDecimalPlaces": 2,
      "unit": "in²",
      "confidence": "high",
      "steps": [
        {
          "label": "The same area",
          "value": 0.6781263562527124,
          "unit": "sq ft"
        },
        {
          "label": "Vents at the chosen rating",
          "value": 11,
          "unit": "vents"
        },
        {
          "label": "Under-floor area",
          "value": 1162.50232500465,
          "unit": "sq ft"
        },
        {
          "label": "By the wall run (1,500 mm² per metre)",
          "value": 97.6501953003906,
          "unit": "in²"
        },
        {
          "label": "By the floor area (500 mm² per m²)",
          "value": 83.7001674003348,
          "unit": "in²"
        },
        {
          "label": "Clear void under a timber floor",
          "value": 5.905511811023622,
          "unit": "in"
        }
      ],
      "basis": "cited",
      "sourceIndex": 2
    }
  ]
}