  "version": "v1",
  "source": "https://craftquantities.com",
  "licence": "CC BY 4.0",
  "licenceUrl": "https://creativecommons.org/licenses/by/4.0/",
  "attribution": "Craft Quantities — craftquantities.com",
  "documentation": "https://craftquantities.com/api/",
  "versioning": "Fields are added, never removed or repurposed, within a version. A breaking change becomes /api/v2/ and v1 keeps being built.",
  "slug": "concrete-vibrator-insertion-spacing-calculator",
  "category": "materials-quantities",
  "title": "Concrete Poker Vibrator Insertion Spacing Calculator",
  "description": "Space poker (immersion) vibrator insertions so their radii overlap by your margin, with the insertions each square metre or square foot of lift takes.",
  "url": "https://craftquantities.com/calculators/materials-quantities/concrete-vibrator-insertion-spacing-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/concrete-vibrator-insertion-spacing-calculator.json",
  "inputCount": 4,
  "testCaseCount": 2,
  "sourceCount": 3,
  "lastVerified": "2026-08-30",
  "translations": {
    "es-US": "https://craftquantities.com/es/calculators/materials-quantities/concrete-vibrator-insertion-spacing-calculator/"
  },
  "citation": {
    "author": "Craft Quantities",
    "title": "Concrete Poker Vibrator Insertion Spacing Calculator",
    "version": "1.0.0",
    "sourcesChecked": "2026-08-30",
    "url": "https://craftquantities.com/calculators/materials-quantities/concrete-vibrator-insertion-spacing-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. Concrete Poker Vibrator Insertion Spacing Calculator. Version 1.0.0. Sources checked 2026-08-30. https://craftquantities.com/calculators/materials-quantities/concrete-vibrator-insertion-spacing-calculator/",
      "apa": "Craft Quantities. (2026). Concrete Poker Vibrator Insertion Spacing Calculator (Version 1.0.0) [Web calculator]. Retrieved from https://craftquantities.com/calculators/materials-quantities/concrete-vibrator-insertion-spacing-calculator/",
      "harvard": "Craft Quantities (2026) Concrete Poker Vibrator Insertion Spacing Calculator (Version 1.0.0). Available at: https://craftquantities.com/calculators/materials-quantities/concrete-vibrator-insertion-spacing-calculator/",
      "bibtex": "@misc{craftquantities-calculators-materials-quantities-concrete-vibrator-insertion-spacing-calculator,\n  author       = {{Craft Quantities}},\n  title        = {Concrete Poker Vibrator Insertion Spacing Calculator},\n  version      = {1.0.0},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/materials-quantities/concrete-vibrator-insertion-spacing-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "radiusOfAction",
      "label": "Radius of Action of the Head",
      "type": "number",
      "dimension": "length",
      "defaultValue": 0.25,
      "min": 0.05,
      "max": 0.6,
      "step": 0.01,
      "help": "The distance from the head over which the concrete is actually consolidated."
    },
    {
      "id": "overlapPercent",
      "label": "Required Overlap of Adjacent Radii (%)",
      "type": "number",
      "defaultValue": 25,
      "min": 0,
      "max": 60,
      "step": 1,
      "help": "How much the circles of action are made to overlap rather than merely touch."
    },
    {
      "id": "layerDepth",
      "label": "Depth of Each Placement Layer",
      "type": "number",
      "dimension": "length",
      "defaultValue": 0.4,
      "min": 0.15,
      "max": 0.9,
      "step": 0.05,
      "help": "The thickness of concrete placed in one pass before the next layer goes on."
    },
    {
      "id": "penetrationIntoPreviousLayer",
      "label": "Penetration into the Layer Below",
      "type": "number",
      "dimension": "length",
      "defaultValue": 0.15,
      "min": 0.05,
      "max": 0.3,
      "step": 0.01,
      "help": "How far the head is driven into the previous layer to knit the two together."
    }
  ],
  "sources": [
    {
      "label": "ACI 309R, Guide for Consolidation of Concrete — consolidation technique is vertical insertion under the head's own weight, a short hold, slow withdrawal, and insertion points spaced so that their radii of action overlap"
    },
    {
      "label": "Spacing = 2 × radius of action × (1 − overlap fraction); insertion points per unit area = 1 ÷ spacing², for a square insertion grid"
    },
    {
      "label": "The radius of action is a property of the head and the mix rather than a constant — it is published by the vibrator manufacturer for the head diameter and frequency, and it shortens in a stiff or heavily reinforced mix"
    }
  ],
  "testCases": [
    {
      "name": "250 mm radius of action with a quarter overlap",
      "inputs": {
        "radiusOfAction": 0.25,
        "overlapPercent": 25,
        "layerDepth": 0.4,
        "penetrationIntoPreviousLayer": 0.15
      },
      "expected": 375,
      "toleranceDecimalPlaces": 2,
      "unit": "mm",
      "confidence": "medium",
      "steps": [
        {
          "label": "Insertions needed per unit of lift area",
          "value": 7.111111111111111,
          "unit": "points/m²"
        },
        {
          "label": "Overlap achieved between adjacent circles of action",
          "value": 125,
          "unit": "mm"
        },
        {
          "label": "Minimum vibrating length to reach the layer below",
          "value": 550,
          "unit": "mm"
        },
        {
          "label": "Ground consolidated by one insertion",
          "value": 0.140625,
          "unit": "m²"
        }
      ],
      "basis": "ambiguous"
    },
    {
      "name": "300 mm radius of action with a heavy 40% overlap in congested steel",
      "inputs": {
        "radiusOfAction": 0.3,
        "overlapPercent": 40,
        "layerDepth": 0.5,
        "penetrationIntoPreviousLayer": 0.15
      },
      "expected": 360,
      "toleranceDecimalPlaces": 2,
      "unit": "mm",
      "confidence": "medium",
      "steps": [
        {
          "label": "Insertions needed per unit of lift area",
          "value": 7.71604938271605,
          "unit": "points/m²"
        },
        {
          "label": "Overlap achieved between adjacent circles of action",
          "value": 240,
          "unit": "mm"
        },
        {
          "label": "Minimum vibrating length to reach the layer below",
          "value": 650,
          "unit": "mm"
        },
        {
          "label": "Ground consolidated by one insertion",
          "value": 0.1296,
          "unit": "m²"
        }
      ],
      "basis": "ambiguous"
    }
  ]
}