  "version": "v1",
  "source": "https://craftquantities.com",
  "licence": "CC BY 4.0",
  "licenceUrl": "https://creativecommons.org/licenses/by/4.0/",
  "attribution": "Craft Quantities — craftquantities.com",
  "documentation": "https://craftquantities.com/api/",
  "versioning": "Fields are added, never removed or repurposed, within a version. A breaking change becomes /api/v2/ and v1 keeps being built.",
  "slug": "concrete-mix-temperature-calculator",
  "category": "materials-quantities",
  "title": "Concrete Mix Temperature and Ice Substitution Calculator",
  "description": "Predict ready-mix temperature at the plant from each ingredient's mass and temperature, then find the ice or chilled water that brings it to target.",
  "url": "https://craftquantities.com/calculators/materials-quantities/concrete-mix-temperature-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/concrete-mix-temperature-calculator.json",
  "inputCount": 9,
  "testCaseCount": 2,
  "sourceCount": 4,
  "lastVerified": "2026-09-06",
  "translations": {
    "es-US": "https://craftquantities.com/es/calculators/materials-quantities/concrete-mix-temperature-calculator/"
  },
  "citation": {
    "author": "Craft Quantities",
    "title": "Concrete Mix Temperature and Ice Substitution Calculator",
    "version": "1.0.1",
    "sourcesChecked": "2026-09-06",
    "url": "https://craftquantities.com/calculators/materials-quantities/concrete-mix-temperature-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. Concrete Mix Temperature and Ice Substitution Calculator. Version 1.0.1. Sources checked 2026-09-06. https://craftquantities.com/calculators/materials-quantities/concrete-mix-temperature-calculator/",
      "apa": "Craft Quantities. (2026). Concrete Mix Temperature and Ice Substitution Calculator (Version 1.0.1) [Web calculator]. Retrieved from https://craftquantities.com/calculators/materials-quantities/concrete-mix-temperature-calculator/",
      "harvard": "Craft Quantities (2026) Concrete Mix Temperature and Ice Substitution Calculator (Version 1.0.1). Available at: https://craftquantities.com/calculators/materials-quantities/concrete-mix-temperature-calculator/",
      "bibtex": "@misc{craftquantities-calculators-materials-quantities-concrete-mix-temperature-calculator,\n  author       = {{Craft Quantities}},\n  title        = {Concrete Mix Temperature and Ice Substitution Calculator},\n  version      = {1.0.1},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/materials-quantities/concrete-mix-temperature-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "cementMass",
      "label": "Cement Mass in the Batch",
      "type": "number",
      "dimension": "weight",
      "defaultValue": 320,
      "min": 50,
      "max": 700,
      "step": 5,
      "help": "Cementitious content of one batch, as batched."
    },
    {
      "id": "cementTemp",
      "label": "Cement Temperature",
      "type": "number",
      "dimension": "temperature",
      "defaultValue": 40,
      "min": 0,
      "max": 90,
      "step": 1,
      "help": "Temperature of the cement as it leaves the silo."
    },
    {
      "id": "aggregateMass",
      "label": "Total Aggregate Mass in the Batch",
      "type": "number",
      "dimension": "weight",
      "defaultValue": 1850,
      "min": 500,
      "max": 3000,
      "step": 10,
      "help": "Coarse and fine aggregate together, dry, for the same batch."
    },
    {
      "id": "aggregateTemp",
      "label": "Aggregate Temperature",
      "type": "number",
      "dimension": "temperature",
      "defaultValue": 28,
      "min": -10,
      "max": 60,
      "step": 1,
      "help": "Temperature of the stockpile at the depth the loader is digging."
    },
    {
      "id": "freeMoisturePercent",
      "label": "Free Moisture on the Aggregate (% of dry mass)",
      "type": "number",
      "defaultValue": 3,
      "min": 0,
      "max": 10,
      "step": 0.5,
      "help": "Surface water carried on the stone, as a percentage of its dry mass."
    },
    {
      "id": "mixWaterMass",
      "label": "Batch Water Added at the Plant",
      "type": "number",
      "dimension": "weight",
      "defaultValue": 150,
      "min": 20,
      "max": 300,
      "step": 5,
      "help": "Water added at the plant, excluding whatever the aggregate brought with it."
    },
    {
      "id": "mixWaterTemp",
      "label": "Batch Water Temperature",
      "type": "number",
      "dimension": "temperature",
      "defaultValue": 20,
      "min": 0,
      "max": 80,
      "step": 1,
      "help": "Temperature of the liquid water as batched."
    },
    {
      "id": "icePercent",
      "label": "Share of the Batch Water Weighed Out as Ice (%)",
      "type": "number",
      "defaultValue": 0,
      "min": 0,
      "max": 75,
      "step": 5,
      "help": "How much of the batch water is charged as flaked or crushed ice instead of liquid."
    },
    {
      "id": "targetTemp",
      "label": "Target Concrete Temperature",
      "type": "number",
      "dimension": "temperature",
      "defaultValue": 30,
      "min": 5,
      "max": 35,
      "step": 1,
      "help": "The as-delivered temperature the specification allows or requires."
    }
  ],
  "sources": [
    {
      "label": "ACI 305R Guide to Hot Weather Concreting mixing-temperature equation: T = [0.22(Ta·Ma + Tc·Mc) + Tw·Mw + Twa·Mwa] / [0.22(Ma + Mc) + Mw + Mwa], where 0.22 is the ratio of the specific heat of cement and aggregate to that of water, Mwa is the free moisture riding on the aggregate and Twa its temperature"
    },
    {
      "label": "Ice substitution, from the same equation: subtract 79.6 x Mi from the numerator and add Mi to the denominator, working in °C and kilograms. 79.6 is the latent heat of fusion of ice divided by the specific heat of water, with the ice taken as being at 0 °C"
    },
    {
      "label": "ACI 305.1 Specification for Hot Weather Concreting — the specification that sets a maximum as-delivered temperature and the protection measures that go with it"
    },
    {
      "label": "ACI 306.1 Specification for Cold Weather Concreting — the minimum as-placed temperatures that govern the other end of the target range, and the reason heated water is a substitution as legitimate as ice"
    }
  ],
  "testCases": [
    {
      "name": "Hot stockpile, no ice",
      "inputs": {
        "cementMass": 320,
        "cementTemp": 40,
        "aggregateMass": 1850,
        "aggregateTemp": 28,
        "freeMoisturePercent": 3,
        "mixWaterMass": 150,
        "mixWaterTemp": 20,
        "icePercent": 0,
        "targetTemp": 30
      },
      "expected": 27.48,
      "toleranceDecimalPlaces": 2,
      "unit": "°C",
      "confidence": "medium",
      "steps": [
        {
          "label": "Same batch with no ice substituted",
          "value": 27.47986528042173,
          "unit": "°C"
        },
        {
          "label": "Difference from the target",
          "value": -2.5201347195782695,
          "unit": "Δ°C"
        },
        {
          "label": "Ice charged",
          "value": 0,
          "unit": "kg"
        },
        {
          "label": "Liquid water charged",
          "value": 150,
          "unit": "kg"
        },
        {
          "label": "Free moisture riding on the aggregate",
          "value": 55.5,
          "unit": "kg"
        },
        {
          "label": "Ice that would reach the target on its own",
          "value": 0,
          "unit": "kg"
        },
        {
          "label": "Water temperature that would reach the target",
          "value": 31.473333333333333,
          "unit": "°C"
        }
      ],
      "basis": "ambiguous"
    },
    {
      "name": "Same batch with 30% of the water as ice",
      "inputs": {
        "cementMass": 320,
        "cementTemp": 40,
        "aggregateMass": 1850,
        "aggregateTemp": 28,
        "freeMoisturePercent": 3,
        "mixWaterMass": 150,
        "mixWaterTemp": 20,
        "icePercent": 30,
        "targetTemp": 30
      },
      "expected": 20.917,
      "toleranceDecimalPlaces": 2,
      "unit": "°C",
      "confidence": "medium",
      "steps": [
        {
          "label": "Same batch with no ice substituted",
          "value": 27.47986528042173,
          "unit": "°C"
        },
        {
          "label": "Difference from the target",
          "value": -9.083321130472982,
          "unit": "Δ°C"
        },
        {
          "label": "Ice charged",
          "value": 45,
          "unit": "kg"
        },
        {
          "label": "Liquid water charged",
          "value": 105,
          "unit": "kg"
        },
        {
          "label": "Free moisture riding on the aggregate",
          "value": 55.5,
          "unit": "kg"
        },
        {
          "label": "Ice that would reach the target on its own",
          "value": 0,
          "unit": "kg"
        },
        {
          "label": "Water temperature that would reach the target",
          "value": 79.07619047619048,
          "unit": "°C"
        }
      ],
      "basis": "ambiguous"
    }
  ]
}