  "version": "v1",
  "source": "https://craftquantities.com",
  "licence": "CC BY 4.0",
  "licenceUrl": "https://creativecommons.org/licenses/by/4.0/",
  "attribution": "Craft Quantities — craftquantities.com",
  "documentation": "https://craftquantities.com/api/",
  "versioning": "Fields are added, never removed or repurposed, within a version. A breaking change becomes /api/v2/ and v1 keeps being built.",
  "slug": "cmu-anchor-embedment-calculator",
  "category": "materials-quantities",
  "title": "CMU Anchor Embedment Scaling Calculator",
  "description": "Scale a masonry anchor's rated pull-out capacity to a different embedment depth, from its manufacturer's reference test data.",
  "url": "https://craftquantities.com/calculators/materials-quantities/cmu-anchor-embedment-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/cmu-anchor-embedment-calculator.json",
  "inputCount": 4,
  "testCaseCount": 3,
  "sourceCount": 2,
  "lastVerified": "2026-09-03",
  "citation": {
    "author": "Craft Quantities",
    "title": "CMU Anchor Embedment Scaling Calculator",
    "version": "1.0.1",
    "sourcesChecked": "2026-09-03",
    "url": "https://craftquantities.com/calculators/materials-quantities/cmu-anchor-embedment-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. CMU Anchor Embedment Scaling Calculator. Version 1.0.1. Sources checked 2026-09-03. https://craftquantities.com/calculators/materials-quantities/cmu-anchor-embedment-calculator/",
      "apa": "Craft Quantities. (2026). CMU Anchor Embedment Scaling Calculator (Version 1.0.1) [Web calculator]. Retrieved from https://craftquantities.com/calculators/materials-quantities/cmu-anchor-embedment-calculator/",
      "harvard": "Craft Quantities (2026) CMU Anchor Embedment Scaling Calculator (Version 1.0.1). Available at: https://craftquantities.com/calculators/materials-quantities/cmu-anchor-embedment-calculator/",
      "bibtex": "@misc{craftquantities-calculators-materials-quantities-cmu-anchor-embedment-calculator,\n  author       = {{Craft Quantities}},\n  title        = {CMU Anchor Embedment Scaling Calculator},\n  version      = {1.0.1},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/materials-quantities/cmu-anchor-embedment-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "ratedCapacity",
      "label": "Manufacturer Rated Capacity at Reference Embedment",
      "type": "number",
      "dimension": "force",
      "defaultValue": 5000,
      "min": 500,
      "max": 50000,
      "step": 500,
      "help": "The anchor's rated capacity at its tested reference embedment depth, from the manufacturer's ICC-ES report."
    },
    {
      "id": "referenceEmbedment",
      "label": "Reference Embedment Depth",
      "type": "number",
      "dimension": "length",
      "defaultValue": 0.075,
      "min": 0.01,
      "max": 0.2,
      "step": 0.005,
      "help": "The embedment depth the rated capacity was tested at."
    },
    {
      "id": "actualEmbedment",
      "label": "Actual (Planned) Embedment Depth",
      "type": "number",
      "dimension": "length",
      "defaultValue": 0.1,
      "min": 0.01,
      "max": 0.2,
      "step": 0.005,
      "help": "The embedment depth you're actually planning to use."
    },
    {
      "id": "wallCondition",
      "label": "Wall Condition at the Anchor",
      "type": "select",
      "defaultValue": "unknown",
      "options": [
        {
          "value": "grouted",
          "label": "Cell grouted solid at the anchor"
        },
        {
          "value": "hollow",
          "label": "Hollow cell — the anchor bears in the face shell"
        },
        {
          "value": "unknown",
          "label": "Not established yet"
        }
      ],
      "help": "Whether there is solid material behind the face shell where the anchor lands."
    }
  ],
  "sources": [
    {
      "label": "Masonry anchor capacity is governed by manufacturer ICC-ES evaluation report testing rather than a general calculable formula; a common simplified approximation scales the rated capacity linearly with embedment depth relative to the manufacturer's tested reference embedment"
    },
    {
      "label": "The same approximation does not run the other way: scaling above the tested embedment extrapolates outside the evaluated range, where masonry capacity flattens rather than continuing to rise, so this page holds the result at the rated capacity instead"
    }
  ],
  "testCases": [
    {
      "name": "deeper than the tested embedment returns the rated capacity, not more",
      "inputs": {
        "ratedCapacity": 5000,
        "referenceEmbedment": 0.075,
        "actualEmbedment": 0.1,
        "wallCondition": "grouted"
      },
      "expected": 5,
      "toleranceDecimalPlaces": 2,
      "unit": "kN",
      "confidence": "low",
      "steps": [
        {
          "label": "Rated capacity entered",
          "value": 5,
          "unit": "kN"
        },
        {
          "label": "Embedment ratio applied",
          "value": 1
        }
      ],
      "basis": "ambiguous"
    },
    {
      "name": "shallower than the tested embedment still scales down",
      "inputs": {
        "ratedCapacity": 8000,
        "referenceEmbedment": 0.1,
        "actualEmbedment": 0.065,
        "wallCondition": "grouted"
      },
      "expected": 5.2,
      "toleranceDecimalPlaces": 1,
      "unit": "kN",
      "confidence": "low",
      "steps": [
        {
          "label": "Rated capacity entered",
          "value": 8,
          "unit": "kN"
        },
        {
          "label": "Embedment ratio applied",
          "value": 0.65
        }
      ],
      "basis": "ambiguous"
    },
    {
      "name": "at exactly the tested embedment the rated capacity comes through untouched",
      "inputs": {
        "ratedCapacity": 5000,
        "referenceEmbedment": 0.075,
        "actualEmbedment": 0.075,
        "wallCondition": "grouted"
      },
      "expected": 5,
      "toleranceDecimalPlaces": 2,
      "unit": "kN",
      "confidence": "low",
      "steps": [
        {
          "label": "Rated capacity entered",
          "value": 5,
          "unit": "kN"
        },
        {
          "label": "Embedment ratio applied",
          "value": 1
        }
      ],
      "basis": "ambiguous"
    }
  ]
}