  "version": "v1",
  "source": "https://craftquantities.com",
  "licence": "CC BY 4.0",
  "licenceUrl": "https://creativecommons.org/licenses/by/4.0/",
  "attribution": "Craft Quantities — craftquantities.com",
  "documentation": "https://craftquantities.com/api/",
  "versioning": "Fields are added, never removed or repurposed, within a version. A breaking change becomes /api/v2/ and v1 keeps being built.",
  "slug": "cavity-fill-volume-calculator",
  "category": "materials-quantities",
  "title": "Cavity Wall & Stud Bay Insulation Fill Calculator",
  "description": "Fill volume, mass at the installed density, bags and injection holes for retrofitting a closed masonry cavity or drill-and-fill stud bays.",
  "url": "https://craftquantities.com/calculators/materials-quantities/cavity-fill-volume-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/cavity-fill-volume-calculator.json",
  "inputCount": 12,
  "testCaseCount": 3,
  "sourceCount": 10,
  "lastVerified": "2026-09-28",
  "translations": {
    "es-US": "https://craftquantities.com/es/calculators/materials-quantities/cavity-fill-volume-calculator/"
  },
  "citation": {
    "author": "Craft Quantities",
    "title": "Cavity Wall & Stud Bay Insulation Fill Calculator",
    "version": "1.0.0",
    "sourcesChecked": "2026-09-28",
    "url": "https://craftquantities.com/calculators/materials-quantities/cavity-fill-volume-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. Cavity Wall & Stud Bay Insulation Fill Calculator. Version 1.0.0. Sources checked 2026-09-28. https://craftquantities.com/calculators/materials-quantities/cavity-fill-volume-calculator/",
      "apa": "Craft Quantities. (2026). Cavity Wall & Stud Bay Insulation Fill Calculator (Version 1.0.0) [Web calculator]. Retrieved from https://craftquantities.com/calculators/materials-quantities/cavity-fill-volume-calculator/",
      "harvard": "Craft Quantities (2026) Cavity Wall & Stud Bay Insulation Fill Calculator (Version 1.0.0). Available at: https://craftquantities.com/calculators/materials-quantities/cavity-fill-volume-calculator/",
      "bibtex": "@misc{craftquantities-calculators-materials-quantities-cavity-fill-volume-calculator,\n  author       = {{Craft Quantities}},\n  title        = {Cavity Wall & Stud Bay Insulation Fill Calculator},\n  version      = {1.0.0},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/materials-quantities/cavity-fill-volume-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "wallLength",
      "label": "Wall Length",
      "type": "number",
      "dimension": "length",
      "defaultValue": 10,
      "min": 0.1,
      "max": 500,
      "step": 0.1,
      "help": "The length of the elevation being filled, measured along its face."
    },
    {
      "id": "wallHeight",
      "label": "Wall Height to Fill",
      "type": "number",
      "dimension": "length",
      "defaultValue": 2.4,
      "min": 0.1,
      "max": 30,
      "step": 0.1,
      "help": "Masonry: the damp-proof course to the top of the cavity. Framed: one storey's bay, plate to plate."
    },
    {
      "id": "openingsArea",
      "label": "Openings Area (windows and doors)",
      "type": "number",
      "dimension": "area",
      "defaultValue": 4,
      "min": 0,
      "max": 5000,
      "step": 0.1,
      "help": "The combined area of the windows and doors in this run, taken off the wall before the volume is worked out."
    },
    {
      "id": "openingsCount",
      "label": "Number of Openings",
      "type": "number",
      "defaultValue": 3,
      "min": 0,
      "max": 200,
      "step": 1,
      "help": "How many windows and doors there are in this run; each one adds the extra holes set below."
    },
    {
      "id": "cavityWidth",
      "label": "Cavity Width or Stud-Bay Depth",
      "type": "number",
      "dimension": "length",
      "defaultValue": 0.065,
      "min": 0.01,
      "max": 0.4,
      "step": 0.001,
      "help": "The clear gap to fill: the width measured at the survey holes, 65 mm (2.56 in) in the masonry example, or a framed wall's stud depth, 3.5 in (89 mm) for a 2x4."
    },
    {
      "id": "studThickness",
      "label": "Stud Thickness (0 for a masonry cavity)",
      "type": "number",
      "dimension": "length",
      "defaultValue": 0,
      "min": 0,
      "max": 0.1,
      "step": 0.001,
      "help": "Leave at 0 mm (0 in) for a masonry cavity; in a framed wall, the stud's face width, 1.5 in (38 mm) for dimensional lumber."
    },
    {
      "id": "holeSpacing",
      "label": "Hole Centres Along a Row (stud spacing if framed)",
      "type": "number",
      "dimension": "length",
      "defaultValue": 1.35,
      "min": 0.1,
      "max": 3,
      "step": 0.01,
      "help": "Masonry: the certificate's spacing along a row, 1.35 m (4.43 ft) for Supafil 34. Framed: the stud centres, 16 in (406 mm) or 24 in (610 mm)."
    },
    {
      "id": "rowSpacing",
      "label": "Row Spacing Up the Wall (height between blocking if framed)",
      "type": "number",
      "dimension": "length",
      "defaultValue": 1.35,
      "min": 0.1,
      "max": 10,
      "step": 0.01,
      "help": "Masonry: the vertical centres of the certificate's rows. Framed: the height of each bay section between blocking, or the storey height if there is none."
    },
    {
      "id": "extraHolesPerOpening",
      "label": "Extra Holes per Opening",
      "type": "number",
      "defaultValue": 2,
      "min": 0,
      "max": 20,
      "step": 1,
      "help": "Holes added for each window or door on top of the regular grid, under a cill, beside a frame, or in a short bay above or below it."
    },
    {
      "id": "installedDensity",
      "label": "Installed Density (from the certificate or chart)",
      "type": "number",
      "dimension": "density",
      "defaultValue": 25,
      "min": 5,
      "max": 150,
      "step": 0.5,
      "help": "The density the fill is blown to in the wall: 25 kg/m³ (1.56 lb/ft³) for Supafil 34, 3.5 lb/ft³ (56 kg/m³) for dense-pack cellulose."
    },
    {
      "id": "bagMass",
      "label": "Bag Mass",
      "type": "number",
      "dimension": "weight",
      "defaultValue": 15.5,
      "min": 1,
      "max": 1000,
      "step": 0.1,
      "help": "The mass of one bag or bale as sold: 15.5 kg (34.2 lb) for a Supafil 34 bale, 30 lb (13.6 kg) nominal for a GreenFiber INS515LD cellulose bag."
    },
    {
      "id": "wastePercent",
      "label": "Waste Allowance (%)",
      "type": "number",
      "defaultValue": 0,
      "min": 0,
      "max": 50,
      "step": 1,
      "help": "A share added to the fill mass for material lost in the hose, blown into the loft and cleared out, or left in a part-used bag."
    }
  ],
  "sources": [
    {
      "label": "BBA Agrément Certificate 11/4857, Product Sheet 2 Issue 4 (12 December 2023), Knauf Insulation Supafil 34 (Retrofit): a site assessment by a trained assessor before installation (A.1); target mean installed density 25 kg/m³ (±5) over the whole wall (9.1.4); bales of about 15.5 kg (11.1); nominal cavity not less than 50 mm, and over 200 mm referred to the certificate holder (9.1.2, 9.1.3); 22 mm holes in a diamond pattern at about 1.35 m centres, bottom row about 800 mm above the DPC, top holes within 350 mm of the top and not more than 1 m apart, extra holes under cills and around features (A.5); ventilation openings and flues sleeved before and checked after (9.1.5, A.7); up to 12 m without a waiver (9.1.14)",
      "url": "https://knauf.com/api/download-center/v1/assets/71ae5b5e-94e4-4be5-86fb-67c17c663cf8?download=true"
    },
    {
      "label": "BBA Agrément Certificate 88/2033, Product Sheet 1, fourth issue (26 July 2021), Knauf Insulation Supafil 40: target mean installed density 18 kg/m³ (section 1.2) and bales of about 17.6 kg (section 3.1) — a second product from the same maker, which is why the density and the bag mass are the certificate's, not the page's",
      "url": "https://pim.knaufinsulation.com/files/download/knauf_insulation_supafil_40_bba_certificate_88_2033-uk-en.pdf"
    },
    {
      "label": "BBA Agrément Certificate 04/4167, Product Sheet 1, third issue (4 June 2020), Springvale Ecobead Platinum bonded EPS bead: target mean installed density 12 kg/m³ (±2) (section 1.2); 22 mm holes at about 600 mm intervals, holes about 250 mm below openings and between them, rows not more than 2.5 m apart (18.1–18.3); bead delivered in sacks or bulk containers (3.1)",
      "url": "https://springvale.com/wp-content/uploads/2020/07/bba-04-4167-ecobead-dated-june-2020.pdf"
    },
    {
      "label": "GreenFiber INS515LD application coverage chart (manufacturer's data sheet): 30 lb nominal bag, minimum net weight 28.5 lb; dry dense-pack sidewall at 3.5 pcf minimum installed density; a 2x4 wall at 3.5 in takes 1.02 lb/sq ft, 29.39 sq ft a bag before framing and 32.4 sq ft at 16 in centres; framing factor 9.375% at 16 in centres and 6.25% at 24 in",
      "url": "http://pdf.lowes.com/operatingguides/729477005157_oper.pdf"
    },
    {
      "label": "US DOE Building America Solution Center (PNNL): 'Dense-Pack Insulation' — cellulose dense-packed at 3.5 to 4.5 lb/ft³ (56 to 72 kg/m³); 'Blown Insulation for Cavities of Existing Exterior Walls' — a 1 in or 2 in hole in the centre of each stud cavity about 6 in below the ceiling, an additional hole below any blocking, and knob-and-tube wiring not to be surrounded by insulation",
      "url": "https://basc.pnnl.gov/resource-guides/blown-insulation-cavities-existing-exterior-walls"
    },
    {
      "label": "Ofgem / ECO Reporting Working Group, Guidance on suitable photographic evidence of retrofitted CWI, Version 1.0 (October 2020): standard drill holes of approximately 18–25 mm in the mortar joints, a pattern determined by the product manufacturer or certification body, concentrated round windows and doors and under waste pipes and vents; lance installations drilled at the corners of elevations, typically 27–40 mm",
      "url": "https://www.ofgem.gov.uk/sites/default/files/docs/2020/10/ftch_drill_patterns_final.pdf"
    },
    {
      "label": "BS 8208-1:1985, Guide to assessment of suitability of external cavity walls for filling with thermal insulants — Part 1: Existing traditional cavity construction — withdrawn by BSI on 1 July 2009 and still cited in Approved Document D (1992 edition incorporating the 2002 and 2010 amendments) for foam fill; the withdrawn guide behind the survey this page leaves to the installer"
    },
    {
      "label": "NFPA 70, National Electrical Code, Article 394.12 — concealed knob-and-tube wiring is not permitted in hollow wall spaces insulated by loose, rolled or foamed-in-place insulation that envelops the conductors"
    },
    {
      "label": "US EPA Renovation, Repair and Painting Rule, 40 CFR Part 745 Subpart E: the rule applies to renovations performed for compensation in target housing (§745.82), and work in housing built before 1978 that disturbs more than 20 sq ft of painted exterior surface is not minor repair (§745.83)",
      "url": "https://www.law.cornell.edu/cfr/text/40/745.83"
    },
    {
      "label": "The Building Regulations 2010 (England), regulation 3(1)(e): the insertion of insulating material into the cavity wall of a building is building work; the Cavity Insulation Guarantee Agency (CIGA) registers the guarantee a UK installer issues",
      "url": "https://www.legislation.gov.uk/uksi/2010/2214/regulation/3"
    }
  ],
  "testCases": [
    {
      "name": "UK opening: 10 x 2.4 m wall, 4 m² of openings, 65 mm cavity, Supafil 34 in 15.5 kg bales",
      "inputs": {
        "wallLength": 10,
        "wallHeight": 2.4,
        "openingsArea": 4,
        "openingsCount": 3,
        "cavityWidth": 0.065,
        "studThickness": 0,
        "holeSpacing": 1.35,
        "rowSpacing": 1.35,
        "extraHolesPerOpening": 2,
        "installedDensity": 25,
        "bagMass": 15.5,
        "wastePercent": 0
      },
      "expected": 3,
      "toleranceDecimalPlaces": 0,
      "unit": "bags",
      "confidence": "high",
      "steps": [
        {
          "label": "Wall area to fill, openings deducted",
          "value": 20,
          "unit": "m²"
        },
        {
          "label": "Fill area, stud faces deducted",
          "value": 20,
          "unit": "m²"
        },
        {
          "label": "Fill volume",
          "value": 45.90906673793516,
          "unit": "ft³"
        },
        {
          "label": "Fill mass at the installed density, allowance included",
          "value": 32.5,
          "unit": "kg"
        },
        {
          "label": "Holes along each row",
          "value": 8,
          "unit": "holes"
        },
        {
          "label": "Rows of holes up the wall",
          "value": 2,
          "unit": "rows"
        },
        {
          "label": "Extra holes at openings",
          "value": 6,
          "unit": "holes"
        },
        {
          "label": "Injection holes in all",
          "value": 22,
          "unit": "holes"
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    },
    {
      "name": "The same wall in Supafil 40: 18 kg/m³ from 17.6 kg bales",
      "inputs": {
        "wallLength": 10,
        "wallHeight": 2.4,
        "openingsArea": 4,
        "openingsCount": 3,
        "cavityWidth": 0.065,
        "studThickness": 0,
        "holeSpacing": 1.35,
        "rowSpacing": 1.35,
        "extraHolesPerOpening": 2,
        "installedDensity": 18,
        "bagMass": 17.6,
        "wastePercent": 0
      },
      "expected": 2,
      "toleranceDecimalPlaces": 0,
      "unit": "bags",
      "confidence": "high",
      "steps": [
        {
          "label": "Wall area to fill, openings deducted",
          "value": 20,
          "unit": "m²"
        },
        {
          "label": "Fill area, stud faces deducted",
          "value": 20,
          "unit": "m²"
        },
        {
          "label": "Fill volume",
          "value": 45.90906673793516,
          "unit": "ft³"
        },
        {
          "label": "Fill mass at the installed density, allowance included",
          "value": 23.400000000000002,
          "unit": "kg"
        },
        {
          "label": "Holes along each row",
          "value": 8,
          "unit": "holes"
        },
        {
          "label": "Rows of holes up the wall",
          "value": 2,
          "unit": "rows"
        },
        {
          "label": "Extra holes at openings",
          "value": 6,
          "unit": "holes"
        },
        {
          "label": "Injection holes in all",
          "value": 22,
          "unit": "holes"
        }
      ],
      "basis": "cited",
      "sourceIndex": 1
    },
    {
      "name": "GreenFiber's own case: 100 sq ft of 2x4 wall at 16 in centres, 3.5 pcf, 30 lb bags",
      "inputs": {
        "wallLength": 3.81,
        "wallHeight": 2.4384,
        "openingsArea": 0,
        "openingsCount": 0,
        "cavityWidth": 0.0889,
        "studThickness": 0.0381,
        "holeSpacing": 0.4064,
        "rowSpacing": 2.4384,
        "extraHolesPerOpening": 2,
        "installedDensity": 56.06462,
        "bagMass": 13.607771,
        "wastePercent": 0
      },
      "expected": 4,
      "toleranceDecimalPlaces": 0,
      "unit": "bags",
      "confidence": "high",
      "steps": [
        {
          "label": "Wall area to fill, openings deducted",
          "value": 9.290304,
          "unit": "m²"
        },
        {
          "label": "Fill area, stud faces deducted",
          "value": 8.419338000000002,
          "unit": "m²"
        },
        {
          "label": "Fill volume",
          "value": 26.43229166666667,
          "unit": "ft³"
        },
        {
          "label": "Fill mass at the installed density, allowance included",
          "value": 41.963199021756694,
          "unit": "kg"
        },
        {
          "label": "Holes along each row",
          "value": 10,
          "unit": "holes"
        },
        {
          "label": "Rows of holes up the wall",
          "value": 1,
          "unit": "rows"
        },
        {
          "label": "Extra holes at openings",
          "value": 0,
          "unit": "holes"
        },
        {
          "label": "Injection holes in all",
          "value": 10,
          "unit": "holes"
        }
      ],
      "basis": "cited",
      "sourceIndex": 3
    }
  ],
  "usedByAssemblies": [
    {
      "id": "cavity-wall-insulation",
      "name": "Cavity wall insulation (retrofit fill)"
    }
  ]
}