  "version": "v1",
  "source": "https://craftquantities.com",
  "licence": "CC BY 4.0",
  "licenceUrl": "https://creativecommons.org/licenses/by/4.0/",
  "attribution": "Craft Quantities — craftquantities.com",
  "documentation": "https://craftquantities.com/api/",
  "versioning": "Fields are added, never removed or repurposed, within a version. A breaking change becomes /api/v2/ and v1 keeps being built.",
  "slug": "bathroom-extract-rate-calculator",
  "category": "plumbing-hvac",
  "title": "Bathroom Extract Fan Rate and Duct Resistance Calculator",
  "description": "The extract rate a wet room needs, and the equivalent duct length that decides whether the fan you bought will actually deliver it.",
  "url": "https://craftquantities.com/calculators/plumbing-hvac/bathroom-extract-rate-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/bathroom-extract-rate-calculator.json",
  "inputCount": 6,
  "testCaseCount": 3,
  "sourceCount": 3,
  "lastVerified": "2026-09-24",
  "translations": {
    "es-US": "https://craftquantities.com/es/calculators/plumbing-hvac/bathroom-extract-rate-calculator/"
  },
  "citation": {
    "author": "Craft Quantities",
    "title": "Bathroom Extract Fan Rate and Duct Resistance Calculator",
    "version": "1.0.0",
    "sourcesChecked": "2026-09-24",
    "url": "https://craftquantities.com/calculators/plumbing-hvac/bathroom-extract-rate-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. Bathroom Extract Fan Rate and Duct Resistance Calculator. Version 1.0.0. Sources checked 2026-09-24. https://craftquantities.com/calculators/plumbing-hvac/bathroom-extract-rate-calculator/",
      "apa": "Craft Quantities. (2026). Bathroom Extract Fan Rate and Duct Resistance Calculator (Version 1.0.0) [Web calculator]. Retrieved from https://craftquantities.com/calculators/plumbing-hvac/bathroom-extract-rate-calculator/",
      "harvard": "Craft Quantities (2026) Bathroom Extract Fan Rate and Duct Resistance Calculator (Version 1.0.0). Available at: https://craftquantities.com/calculators/plumbing-hvac/bathroom-extract-rate-calculator/",
      "bibtex": "@misc{craftquantities-calculators-plumbing-hvac-bathroom-extract-rate-calculator,\n  author       = {{Craft Quantities}},\n  title        = {Bathroom Extract Fan Rate and Duct Resistance Calculator},\n  version      = {1.0.0},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/plumbing-hvac/bathroom-extract-rate-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "floorArea",
      "label": "Room floor area",
      "type": "number",
      "dimension": "area",
      "defaultValue": 6,
      "min": 1,
      "max": 60,
      "step": 0.5,
      "help": "The wet room's own floor, not the landing outside it."
    },
    {
      "id": "ceilingHeight",
      "label": "Ceiling height",
      "type": "number",
      "dimension": "length",
      "defaultValue": 2.4,
      "min": 1.8,
      "max": 5,
      "step": 0.05,
      "help": "Floor to ceiling, for the volume."
    },
    {
      "id": "airChanges",
      "label": "Air changes per hour",
      "type": "number",
      "defaultValue": 8,
      "min": 1,
      "max": 30,
      "step": 1,
      "help": "How many times the room's whole volume is replaced each hour."
    },
    {
      "id": "ductLength",
      "label": "Straight duct run",
      "type": "number",
      "dimension": "length",
      "defaultValue": 3,
      "min": 0,
      "max": 30,
      "step": 0.5,
      "help": "Measured along the duct, not across the room."
    },
    {
      "id": "bends",
      "label": "Bends in the run",
      "type": "number",
      "defaultValue": 2,
      "min": 0,
      "max": 12,
      "step": 1,
      "help": "Every change of direction, including the one at the terminal."
    },
    {
      "id": "ductType",
      "label": "Duct type",
      "type": "select",
      "defaultValue": "flexible",
      "options": [
        {
          "value": "flexible",
          "label": "Flexible (corrugated)"
        },
        {
          "value": "rigid",
          "label": "Rigid (smooth bore)"
        }
      ],
      "help": "Corrugated flexible costs far more per bend than rigid."
    }
  ],
  "sources": [
    {
      "label": "Required extract flow is the room volume multiplied by the target air changes per hour, divided by 3.6 to convert cubic metres per hour into litres per second"
    },
    {
      "label": "A fan's quoted flow is measured at zero static pressure — free air, with no duct attached — so it is an upper bound rather than a delivered rate, and the difference on a real run is substantial"
    },
    {
      "label": "Duct fittings are costed as an equivalent length of the same straight duct; a bend in corrugated flexible duct is worth considerably more than the same bend in rigid, because the inner wall compresses as it turns"
    }
  ],
  "testCases": [
    {
      "name": "6 m² room at 2.4 m, 8 air changes",
      "inputs": {
        "floorArea": 6,
        "ceilingHeight": 2.4,
        "airChanges": 8,
        "ductLength": 3,
        "bends": 2,
        "ductType": "flexible"
      },
      "expected": 67.804,
      "toleranceDecimalPlaces": 2,
      "unit": "CFM",
      "confidence": "medium",
      "steps": [
        {
          "label": "Room volume",
          "value": 508.5312007894356,
          "unit": "ft³"
        },
        {
          "label": "Equivalent duct length",
          "value": 26.246719160104984,
          "unit": "ft"
        },
        {
          "label": "Each bend is worth",
          "value": 8.202099737532809,
          "unit": "ft of duct"
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    },
    {
      "name": "The same room at 15 air changes, as a shower room",
      "inputs": {
        "floorArea": 6,
        "ceilingHeight": 2.4,
        "airChanges": 15,
        "ductLength": 3,
        "bends": 2,
        "ductType": "flexible"
      },
      "expected": 127.133,
      "toleranceDecimalPlaces": 2,
      "unit": "CFM",
      "confidence": "medium",
      "steps": [
        {
          "label": "Room volume",
          "value": 508.5312007894356,
          "unit": "ft³"
        },
        {
          "label": "Equivalent duct length",
          "value": 26.246719160104984,
          "unit": "ft"
        },
        {
          "label": "Each bend is worth",
          "value": 8.202099737532809,
          "unit": "ft of duct"
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    },
    {
      "name": "Rigid duct changes the resistance, not the requirement",
      "inputs": {
        "floorArea": 6,
        "ceilingHeight": 2.4,
        "airChanges": 8,
        "ductLength": 3,
        "bends": 2,
        "ductType": "rigid"
      },
      "expected": 67.804,
      "toleranceDecimalPlaces": 2,
      "unit": "CFM",
      "confidence": "medium",
      "steps": [
        {
          "label": "Room volume",
          "value": 508.5312007894356,
          "unit": "ft³"
        },
        {
          "label": "Equivalent duct length",
          "value": 16.404199475065617,
          "unit": "ft"
        },
        {
          "label": "Each bend is worth",
          "value": 3.280839895013123,
          "unit": "ft of duct"
        }
      ],
      "basis": "cited",
      "sourceIndex": 2
    }
  ],
  "usedByAssemblies": [
    {
      "id": "bathroom-remodel",
      "name": "Bathroom remodel"
    },
    {
      "id": "bathroom-ventilation",
      "name": "Bathroom ventilation"
    }
  ]
}