  "version": "v1",
  "source": "https://craftquantities.com",
  "licence": "CC BY 4.0",
  "licenceUrl": "https://creativecommons.org/licenses/by/4.0/",
  "attribution": "Craft Quantities — craftquantities.com",
  "documentation": "https://craftquantities.com/api/",
  "versioning": "Fields are added, never removed or repurposed, within a version. A breaking change becomes /api/v2/ and v1 keeps being built.",
  "slug": "awg-to-mm2-calculator",
  "category": "electrical",
  "title": "AWG to mm² Wire Size Calculator",
  "description": "Convert American Wire Gauge to a metric conductor cross-section and back, with the nearest standard size in the other system.",
  "url": "https://craftquantities.com/calculators/electrical/awg-to-mm2-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/awg-to-mm2-calculator.json",
  "inputCount": 3,
  "testCaseCount": 5,
  "sourceCount": 3,
  "lastVerified": "2026-09-11",
  "citation": {
    "author": "Craft Quantities",
    "title": "AWG to mm² Wire Size Calculator",
    "version": "1.0.0",
    "sourcesChecked": "2026-09-11",
    "url": "https://craftquantities.com/calculators/electrical/awg-to-mm2-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. AWG to mm² Wire Size Calculator. Version 1.0.0. Sources checked 2026-09-11. https://craftquantities.com/calculators/electrical/awg-to-mm2-calculator/",
      "apa": "Craft Quantities. (2026). AWG to mm² Wire Size Calculator (Version 1.0.0) [Web calculator]. Retrieved from https://craftquantities.com/calculators/electrical/awg-to-mm2-calculator/",
      "harvard": "Craft Quantities (2026) AWG to mm² Wire Size Calculator (Version 1.0.0). Available at: https://craftquantities.com/calculators/electrical/awg-to-mm2-calculator/",
      "bibtex": "@misc{craftquantities-calculators-electrical-awg-to-mm2-calculator,\n  author       = {{Craft Quantities}},\n  title        = {AWG to mm² Wire Size Calculator},\n  version      = {1.0.0},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/electrical/awg-to-mm2-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "direction",
      "label": "Convert",
      "type": "select",
      "defaultValue": "awg-to-mm2",
      "options": [
        {
          "value": "awg-to-mm2",
          "label": "AWG → mm²"
        },
        {
          "value": "mm2-to-awg",
          "label": "mm² → AWG"
        }
      ],
      "help": "Which way round the conversion runs."
    },
    {
      "id": "gauge",
      "label": "AWG size",
      "type": "select",
      "defaultValue": "6",
      "options": [
        {
          "value": "18",
          "label": "18 AWG"
        },
        {
          "value": "16",
          "label": "16 AWG"
        },
        {
          "value": "14",
          "label": "14 AWG"
        },
        {
          "value": "12",
          "label": "12 AWG"
        },
        {
          "value": "10",
          "label": "10 AWG"
        },
        {
          "value": "8",
          "label": "8 AWG"
        },
        {
          "value": "6",
          "label": "6 AWG"
        },
        {
          "value": "4",
          "label": "4 AWG"
        },
        {
          "value": "3",
          "label": "3 AWG"
        },
        {
          "value": "2",
          "label": "2 AWG"
        },
        {
          "value": "1",
          "label": "1 AWG"
        },
        {
          "value": "0",
          "label": "1/0 AWG"
        },
        {
          "value": "-1",
          "label": "2/0 AWG"
        },
        {
          "value": "-2",
          "label": "3/0 AWG"
        },
        {
          "value": "-3",
          "label": "4/0 AWG"
        }
      ],
      "help": "The gauge on the cable jacket or the drawing."
    },
    {
      "id": "areaMm2",
      "label": "Conductor cross-section (mm²)",
      "type": "number",
      "defaultValue": 16,
      "min": 0.1,
      "max": 500,
      "step": 0.1,
      "help": "The metric conductor size, as printed on the cable or given in the specification."
    }
  ],
  "sources": [
    {
      "label": "AWG is defined geometrically: 4/0 is 0.4600 in and 36 AWG is 0.0050 in, with 39 equal ratio steps between them, so diameter = 0.005 in × 92^((36 − n)/39)"
    },
    {
      "label": "NEC Chapter 9, Table 8 (conductor properties) gives the same areas to three significant figures: 12 AWG = 3.31 mm², 6 AWG = 13.3 mm², 4/0 AWG = 107 mm²"
    },
    {
      "label": "IEC 60228 nominal cross-sectional areas for standard metric conductors: 0.5, 0.75, 1, 1.5, 2.5, 4, 6, 10, 16, 25, 35, 50, 70, 95, 120, 150, 185, 240, 300, 400 mm²"
    }
  ],
  "testCases": [
    {
      "name": "12 AWG is 3.31 mm² (NEC Chapter 9 Table 8)",
      "inputs": {
        "direction": "awg-to-mm2",
        "gauge": "12",
        "areaMm2": 16
      },
      "expected": 3.30877,
      "toleranceDecimalPlaces": 4,
      "unit": "mm²",
      "confidence": "high",
      "steps": [
        {
          "label": "Conductor diameter",
          "value": 2.0525253884939474,
          "unit": "mm"
        },
        {
          "label": "Nearest standard metric size",
          "value": 4,
          "unit": "mm²"
        },
        {
          "label": "Nearest metric size that is not smaller",
          "value": 4,
          "unit": "mm²"
        },
        {
          "label": "Difference from that size",
          "value": 20.890739551179664,
          "unit": "%"
        }
      ],
      "basis": "ambiguous"
    },
    {
      "name": "6 AWG is 13.3 mm²",
      "inputs": {
        "direction": "awg-to-mm2",
        "gauge": "6",
        "areaMm2": 16
      },
      "expected": 13.30177,
      "toleranceDecimalPlaces": 4,
      "unit": "mm²",
      "confidence": "high",
      "steps": [
        {
          "label": "Conductor diameter",
          "value": 4.115378098506909,
          "unit": "mm"
        },
        {
          "label": "Nearest standard metric size",
          "value": 16,
          "unit": "mm²"
        },
        {
          "label": "Nearest metric size that is not smaller",
          "value": 16,
          "unit": "mm²"
        },
        {
          "label": "Difference from that size",
          "value": 20.284763131844745,
          "unit": "%"
        }
      ],
      "basis": "ambiguous"
    },
    {
      "name": "4/0 AWG is 107 mm²",
      "inputs": {
        "direction": "awg-to-mm2",
        "gauge": "-3",
        "areaMm2": 16
      },
      "expected": 107.2193,
      "toleranceDecimalPlaces": 3,
      "unit": "mm²",
      "confidence": "high",
      "steps": [
        {
          "label": "Conductor diameter",
          "value": 11.684,
          "unit": "mm"
        },
        {
          "label": "Nearest standard metric size",
          "value": 95,
          "unit": "mm²"
        },
        {
          "label": "Nearest metric size that is not smaller",
          "value": 120,
          "unit": "mm²"
        },
        {
          "label": "Difference from that size",
          "value": 11.920146014554934,
          "unit": "%"
        }
      ],
      "basis": "ambiguous"
    },
    {
      "name": "16 mm² needs 4 AWG, which is 21.15 mm²",
      "inputs": {
        "direction": "mm2-to-awg",
        "gauge": "6",
        "areaMm2": 16
      },
      "expected": 21.15064,
      "toleranceDecimalPlaces": 4,
      "unit": "mm² (4 AWG)",
      "confidence": "high",
      "steps": [
        {
          "label": "Area you asked for",
          "value": 16,
          "unit": "mm²"
        },
        {
          "label": "Area of that gauge",
          "value": 21.15063942544283,
          "unit": "mm²"
        },
        {
          "label": "How much larger the gauge is",
          "value": 32.19149640901768,
          "unit": "%"
        },
        {
          "label": "Conductor diameter of that gauge",
          "value": 5.189395968020595,
          "unit": "mm"
        }
      ],
      "basis": "ambiguous"
    },
    {
      "name": "2.5 mm² needs 12 AWG, which is 3.31 mm²",
      "inputs": {
        "direction": "mm2-to-awg",
        "gauge": "6",
        "areaMm2": 2.5
      },
      "expected": 3.30877,
      "toleranceDecimalPlaces": 4,
      "unit": "mm² (12 AWG)",
      "confidence": "high",
      "steps": [
        {
          "label": "Area you asked for",
          "value": 2.5,
          "unit": "mm²"
        },
        {
          "label": "Area of that gauge",
          "value": 3.308772876111475,
          "unit": "mm²"
        },
        {
          "label": "How much larger the gauge is",
          "value": 32.35091504445901,
          "unit": "%"
        },
        {
          "label": "Conductor diameter of that gauge",
          "value": 2.0525253884939474,
          "unit": "mm"
        }
      ],
      "basis": "ambiguous"
    }
  ]
}