  "slug": "attic-ventilation-calculator",
  "category": "insulation-efficiency",
  "title": "Attic and Loft Ventilation Calculator (Intake, Exhaust and Vent Count)",
  "description": "Net free vent area for an attic or cold loft by the IRC, NBC, BS 5250 or NCC, split between eaves intake and high exhaust, and the vents that provide it.",
  "url": "https://craftquantities.com/calculators/insulation-efficiency/attic-ventilation-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/attic-ventilation-calculator.json",
  "inputCount": 8,
  "testCaseCount": 12,
  "sourceCount": 7,
  "lastVerified": "2026-10-05",
  "translations": {
    "es-US": "https://craftquantities.com/es/calculators/insulation-efficiency/attic-ventilation-calculator/"
  },
  "citation": {
    "author": "Craft Quantities",
    "title": "Attic and Loft Ventilation Calculator (Intake, Exhaust and Vent Count)",
    "version": "1.1.0",
    "sourcesChecked": "2026-10-05",
    "url": "https://craftquantities.com/calculators/insulation-efficiency/attic-ventilation-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. Attic and Loft Ventilation Calculator (Intake, Exhaust and Vent Count). Version 1.1.0. Sources checked 2026-10-05. https://craftquantities.com/calculators/insulation-efficiency/attic-ventilation-calculator/",
      "apa": "Craft Quantities. (2026). Attic and Loft Ventilation Calculator (Intake, Exhaust and Vent Count) (Version 1.1.0) [Web calculator]. Retrieved from https://craftquantities.com/calculators/insulation-efficiency/attic-ventilation-calculator/",
      "harvard": "Craft Quantities (2026) Attic and Loft Ventilation Calculator (Intake, Exhaust and Vent Count) (Version 1.1.0). Available at: https://craftquantities.com/calculators/insulation-efficiency/attic-ventilation-calculator/",
      "bibtex": "@misc{craftquantities-calculators-insulation-efficiency-attic-ventilation-calculator,\n  author       = {{Craft Quantities}},\n  title        = {Attic and Loft Ventilation Calculator (Intake, Exhaust and Vent Count)},\n  version      = {1.1.0},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/insulation-efficiency/attic-ventilation-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "atticLength",
      "label": "Attic or Loft Length (along the ridge)",
      "type": "number",
      "dimension": "length",
      "defaultValue": 12,
      "min": 0.01,
      "max": 60,
      "step": 0.5,
      "help": "The length of the attic floor, measured along the ridge; the page takes each eave and the ridge to be this long."
    },
    {
      "id": "atticWidth",
      "label": "Attic or Loft Width (the span, eaves to eaves)",
      "type": "number",
      "dimension": "length",
      "defaultValue": 7.5,
      "min": 0.01,
      "max": 60,
      "step": 0.5,
      "help": "The width of the attic floor, wall plate to wall plate across the building."
    },
    {
      "id": "hasVaporBarrier",
      "label": "Rule",
      "type": "select",
      "defaultValue": "no",
      "options": [
        {
          "value": "no",
          "label": "IRC R806.2: 1/150 of the attic floor (United States)"
        },
        {
          "value": "yes",
          "label": "IRC R806.2 exception: 1/300, with 40–50% of it high up (United States)"
        },
        {
          "value": "nbc",
          "label": "NBC 9.19.1.2: 1/300 of the insulated ceiling (Canada)"
        },
        {
          "value": "nbcLow",
          "label": "NBC 9.19.1.2: 1/150 below a 1 in 6 slope or with roof joists (Canada)"
        },
        {
          "value": "ukLow",
          "label": "BS 5250 cold roof, pitch 15° or less: 25 mm (0.98 in) at the eaves (UK)"
        },
        {
          "value": "ukMid",
          "label": "BS 5250 cold roof, pitch over 15° and under 35°: 10 mm (0.39 in) at the eaves (UK)"
        },
        {
          "value": "ukSteep",
          "label": "BS 5250 cold roof, pitch 35° or more: 10 mm (0.39 in) at the eaves, 5 mm (0.20 in) high up (UK)"
        },
        {
          "value": "auLow",
          "label": "NCC 2022 10.8.3, pitch under 10°: 25,000 mm² a metre (11.8 sq in a foot) at both eaves (Australia, zones 6–8)"
        },
        {
          "value": "auMid",
          "label": "NCC 2022 10.8.3, pitch 10° to under 15°: 25,000 and 5,000 mm² a metre (11.8 and 2.4 sq in a foot) at the eaves and high up (Australia, zones 6–8)"
        },
        {
          "value": "auSteep",
          "label": "NCC 2022 10.8.3, pitch 15° to under 75°: 7,000 and 5,000 mm² a metre (3.3 and 2.4 sq in a foot) at the eaves and high up (Australia, zones 6–8)"
        }
      ],
      "help": "The rule the vent area comes from: the IRC's ratio, Canada's, or the UK's and Australia's openings along the eaves and ridge."
    },
    {
      "id": "exhaustShare",
      "label": "Share of the Vent Area High Up (%)",
      "type": "number",
      "defaultValue": 50,
      "min": 0,
      "max": 100,
      "step": 1,
      "help": "The part of the total in vents near the ridge, in the upper portion R806.2 describes; the 1/300 exception needs 40 to 50%."
    },
    {
      "id": "intakeVent",
      "label": "Intake Vent (eaves or soffit)",
      "type": "select",
      "defaultValue": "soffit",
      "options": [
        {
          "value": "soffit",
          "label": "Lomanco 140 soffit vent, 88 sq in per 8 ft length"
        },
        {
          "value": "custom",
          "label": "Another intake vent (enter its rating)"
        }
      ],
      "optionsBySystem": {
        "imperial": [
          {
            "value": "soffit",
            "label": "Lomanco 140 soffit vent, 88 sq in per 8 ft length"
          },
          {
            "value": "custom",
            "label": "Another intake vent (enter its rating)"
          }
        ],
        "metric": [
          {
            "value": "soffit",
            "label": "Marley 25 mm eaves vent, 25,000 mm² per metre"
          },
          {
            "value": "custom",
            "label": "Another intake vent (enter its rating)"
          }
        ]
      },
      "help": "The intake product, so the page can count it; the slot is a real product rated by its maker."
    },
    {
      "id": "intakeArea",
      "label": "Net Free Area of One Intake Vent",
      "type": "number",
      "dimension": "area",
      "defaultValue": 0.025,
      "min": 0.00001,
      "max": 1,
      "step": 0.00001,
      "help": "From the vent's label or data sheet: its net free area, after the louvres, mesh and insect screen."
    },
    {
      "id": "exhaustVent",
      "label": "Exhaust Vent (ridge or upper)",
      "type": "select",
      "defaultValue": "ridge",
      "options": [
        {
          "value": "ridge",
          "label": "GAF Cobra RidgeRunner ridge vent, 12.5 sq in per foot"
        },
        {
          "value": "custom",
          "label": "Another exhaust vent (enter its rating)"
        }
      ],
      "optionsBySystem": {
        "imperial": [
          {
            "value": "ridge",
            "label": "GAF Cobra RidgeRunner ridge vent, 12.5 sq in per foot"
          },
          {
            "value": "custom",
            "label": "Another exhaust vent (enter its rating)"
          }
        ],
        "metric": [
          {
            "value": "ridge",
            "label": "GAF Cobra RidgeRunner ridge vent, 26,458 mm² per metre"
          },
          {
            "value": "custom",
            "label": "Another exhaust vent (enter its rating)"
          }
        ]
      },
      "help": "The exhaust product high on the roof: a ridge vent, or individual roof vents."
    },
    {
      "id": "exhaustArea",
      "label": "Net Free Area of One Exhaust Vent",
      "type": "number",
      "dimension": "area",
      "defaultValue": 0.026458,
      "min": 0.00001,
      "max": 1,
      "step": 0.00001,
      "help": "From the label or data sheet: the net free area of one roof vent, or of one piece of a continuous ridge vent."
    }
  ],
  "sources": [
    {
      "label": "International Code Council, 2021 International Residential Code, as adopted without amendment in the Colorado Division of Fire Prevention and Control Residential Code 2021: R806.2, net free ventilating area 1/150 of the vented space; exception, 1/300 where both conditions are met: a Class I or II vapor retarder on the warm-in-winter side of the ceiling in climate zones 6, 7 and 8, and 40 to 50 percent of the required area in ventilators in the upper portion of the attic or rafter space",
      "url": "https://up.codes/s/minimum-vent-area"
    },
    {
      "label": "Residential Code of Ohio, Ohio Adm. Code 4101:8-8-01 (effective 1 July 2019), sections 806.1–806.3 on the 2018 IRC text: upper ventilators not more than 3 ft (914 mm) below the ridge or highest point, measured vertically; the balance in the bottom one-third of the attic space; installation lower where framing conflicts; not less than 1 in (25 mm) between insulation and roof sheathing (Ohio deletes the exception's vapor-retarder condition)",
      "url": "https://www.law.cornell.edu/regulations/ohio/Ohio-Admin-Code-4101-8-8-01"
    },
    {
      "label": "National Research Council of Canada, National Building Code of Canada 2020, Division B, 9.19.1.1–9.19.1.3: vent area not less than 1/300 of the insulated ceiling area, or 1/150 where the roof slope is less than 1 in 6 or the roof has roof joists; vents distributed uniformly on opposite sides, at least 25% at the top and at least 25% at the bottom of the space; 63 mm between insulation and sheathing"
    },
    {
      "label": "Marley, 'How do I ventilate a cold roof?' (technical support guidance, citing BS 5250, Management of moisture in buildings): with a high-resistance underlay, 25 mm along the eaves for pitches of 15° or less, 10 mm for pitches above 15°, and 5 mm at high level where the pitch exceeds 35°, the span exceeds 10 m, or the roof is lean-to or mono-pitch; Wienerberger, 'Roof space ventilation' (2013): a continuous 10 mm gap gives 10,000 mm² per metre run, and the 5 mm high-level vent where a building is 10 metres wide or more or the pitch 35 degrees or above (the page takes this, the stricter reading at the boundaries). Approved Document C (2013) 6.10–6.11 refers roof condensation to BS 5250",
      "url": "https://cm.marley.co.uk/support/ventilation-and-dry-fix/how-do-i-ventilate-a-cold-roof"
    },
    {
      "label": "Vent ratings and the balance rule: GAF Cobra RidgeRunner data sheet RESCB171 (2020), 12.5 sq in per lineal foot (26,458 mm² per lineal metre), exhaust never to exceed intake, and the chart 1,600 sq ft to 31 ft with 388 sq in of intake; Lomanco 140 soffit vent product specification (2012), 88 sq in per 8 ft unit; Marley Ventilated Dry Ridge System, 5 mm continuous",
      "url": "https://images.homedepot-static.com/catalog/pdfImages/f5/f54f679c-2cad-4c8e-9837-dfd36ad2bf3e.pdf"
    },
    {
      "label": "Marley, Universal 25mm Eaves Vent System: 25,000 mm² free area of ventilation per linear metre, for roof pitches of 12.5° to 55° (product page; Marley's NBS Source data, ventilation opening 25 000 mm²/m, 6000 mm packs; fixing instructions, December 2018, a continuous 25 mm free ventilation path, pack code 46351)",
      "url": "https://cm.marley.co.uk/accessories/25mm-eaves-vent-system"
    },
    {
      "label": "Australian Building Codes Board, National Construction Code 2022 (as adopted), Housing Provisions 10.8.3, ventilation of roof spaces: in climate zones 6, 7 and 8, Table 10.8.3, under 10° pitch 25,000 mm²/m at each of two opposing ends; 10° to under 15°, 25,000 mm²/m at the eaves and 5,000 mm²/m at high level; 15° to under 75°, 7,000 mm²/m at the eaves and 5,000 mm²/m at high level, plus 18,000 mm²/m at the eaves for a cathedral ceiling; areas per metre of the roof's longest horizontal dimension; high level within 900 mm below the ridge; not for concrete roofs, structural insulated panels or BAL-FZ. Applied along both eaves as the Australian Steel Institute's 'Ventilation in Steel Roofing' (VSR V27, 2024) works the table for a gable or hipped roof",
      "url": "https://ncc.abcb.gov.au/editions/ncc-2022/adopted/housing-provisions/10-health-and-amenity/part-108-condensation-management"
    }
  ],
  "testCases": [
    {
      "name": "12x8m attic, no vapor barrier",
      "inputs": {
        "atticLength": 12,
        "atticWidth": 8,
        "hasVaporBarrier": "no"
      },
      "expected": 6.89,
      "toleranceDecimalPlaces": 1,
      "unit": "sq ft (net free area)",
      "confidence": "medium",
      "steps": [
        {
          "label": "Attic floor area",
          "value": 1033.3354000041334,
          "unit": "sq ft"
        },
        {
          "label": "Net free area needed",
          "value": 640000,
          "unit": "mm²"
        },
        {
          "label": "Intake, low on the roof (eaves or soffit)",
          "value": 322580.00000000006,
          "unit": "mm²"
        },
        {
          "label": "Exhaust, high on the roof (ridge or upper vents)",
          "value": 320000,
          "unit": "mm²"
        },
        {
          "label": "Intake as a continuous gap along both eaves",
          "value": 13.440833333333334,
          "unit": "mm"
        },
        {
          "label": "Exhaust as a continuous gap along the ridge",
          "value": 26.666666666666668,
          "unit": "mm"
        },
        {
          "label": "Intake vent to fit",
          "value": 6,
          "unit": "vents (8 ft)"
        },
        {
          "label": "Exhaust vent to fit",
          "value": 40,
          "unit": "ft"
        },
        {
          "label": "High-level share of the total",
          "value": 50,
          "unit": "%"
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    },
    {
      "name": "15x10m attic, with vapor barrier",
      "inputs": {
        "atticLength": 15,
        "atticWidth": 10,
        "hasVaporBarrier": "yes"
      },
      "expected": 5.38,
      "toleranceDecimalPlaces": 1,
      "unit": "sq ft (net free area)",
      "confidence": "medium",
      "steps": [
        {
          "label": "Attic floor area",
          "value": 1614.5865625064582,
          "unit": "sq ft"
        },
        {
          "label": "Net free area needed",
          "value": 500000,
          "unit": "mm²"
        },
        {
          "label": "Intake, low on the roof (eaves or soffit)",
          "value": 258064.00000000003,
          "unit": "mm²"
        },
        {
          "label": "Exhaust, high on the roof (ridge or upper vents)",
          "value": 250000,
          "unit": "mm²"
        },
        {
          "label": "Intake as a continuous gap along both eaves",
          "value": 8.602133333333335,
          "unit": "mm"
        },
        {
          "label": "Exhaust as a continuous gap along the ridge",
          "value": 16.666666666666668,
          "unit": "mm"
        },
        {
          "label": "Intake vent to fit",
          "value": 5,
          "unit": "vents (8 ft)"
        },
        {
          "label": "Exhaust vent to fit",
          "value": 32,
          "unit": "ft"
        },
        {
          "label": "High-level share of the total",
          "value": 50,
          "unit": "%"
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    },
    {
      "name": "GAF's chart: 1,600 sq ft under the 1/300 exception at 50% high is 5.33 sq ft",
      "inputs": {
        "atticLength": 12.192,
        "atticWidth": 12.192,
        "hasVaporBarrier": "yes",
        "exhaustShare": 50,
        "intakeVent": "soffit",
        "intakeArea": 0.01,
        "exhaustVent": "ridge",
        "exhaustArea": 0.005
      },
      "expected": 5.3333,
      "toleranceDecimalPlaces": 3,
      "unit": "sq ft (net free area)",
      "confidence": "medium",
      "steps": [
        {
          "label": "Attic floor area",
          "value": 1600,
          "unit": "sq ft"
        },
        {
          "label": "Net free area needed",
          "value": 495482.88,
          "unit": "mm²"
        },
        {
          "label": "Intake, low on the roof (eaves or soffit)",
          "value": 249999.5,
          "unit": "mm²"
        },
        {
          "label": "Exhaust, high on the roof (ridge or upper vents)",
          "value": 247741.44,
          "unit": "mm²"
        },
        {
          "label": "Intake as a continuous gap along both eaves",
          "value": 10.252604166666666,
          "unit": "mm"
        },
        {
          "label": "Exhaust as a continuous gap along the ridge",
          "value": 20.32,
          "unit": "mm"
        },
        {
          "label": "Intake vent to fit",
          "value": 5,
          "unit": "vents (8 ft)"
        },
        {
          "label": "Exhaust vent to fit",
          "value": 31,
          "unit": "ft"
        },
        {
          "label": "High-level share of the total",
          "value": 50,
          "unit": "%"
        }
      ],
      "basis": "cited",
      "sourceIndex": 4
    },
    {
      "name": "The exception missed: 60% high up falls back to 1/150, 10.67 sq ft",
      "inputs": {
        "atticLength": 12.192,
        "atticWidth": 12.192,
        "hasVaporBarrier": "yes",
        "exhaustShare": 60,
        "intakeVent": "soffit",
        "intakeArea": 0.01,
        "exhaustVent": "ridge",
        "exhaustArea": 0.005
      },
      "expected": 10.6667,
      "toleranceDecimalPlaces": 3,
      "unit": "sq ft (net free area)",
      "confidence": "medium",
      "steps": [
        {
          "label": "Attic floor area",
          "value": 1600,
          "unit": "sq ft"
        },
        {
          "label": "Net free area needed",
          "value": 990965.76,
          "unit": "mm²"
        },
        {
          "label": "Intake, low on the roof (eaves or soffit)",
          "value": 596773,
          "unit": "mm²"
        },
        {
          "label": "Exhaust, high on the roof (ridge or upper vents)",
          "value": 594579.456,
          "unit": "mm²"
        },
        {
          "label": "Intake as a continuous gap along both eaves",
          "value": 24.473958333333332,
          "unit": "mm"
        },
        {
          "label": "Exhaust as a continuous gap along the ridge",
          "value": 48.767999999999994,
          "unit": "mm"
        },
        {
          "label": "Intake vent to fit",
          "value": 11,
          "unit": "vents (8 ft)"
        },
        {
          "label": "Exhaust vent to fit",
          "value": 74,
          "unit": "ft"
        },
        {
          "label": "High-level share of the total",
          "value": 60,
          "unit": "%"
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    },
    {
      "name": "NBC 9.19.1.2: 12 x 8 m at 1/300 is 0.32 m², 3.444 sq ft",
      "inputs": {
        "atticLength": 12,
        "atticWidth": 8,
        "hasVaporBarrier": "nbc",
        "exhaustShare": 50,
        "intakeVent": "soffit",
        "intakeArea": 0.01,
        "exhaustVent": "ridge",
        "exhaustArea": 0.005
      },
      "expected": 3.44445,
      "toleranceDecimalPlaces": 4,
      "unit": "sq ft (net free area)",
      "confidence": "medium",
      "steps": [
        {
          "label": "Attic floor area",
          "value": 1033.3354000041334,
          "unit": "sq ft"
        },
        {
          "label": "Net free area needed",
          "value": 320000,
          "unit": "mm²"
        },
        {
          "label": "Intake, low on the roof (eaves or soffit)",
          "value": 161290.00000000003,
          "unit": "mm²"
        },
        {
          "label": "Exhaust, high on the roof (ridge or upper vents)",
          "value": 160000,
          "unit": "mm²"
        },
        {
          "label": "Intake as a continuous gap along both eaves",
          "value": 6.720416666666667,
          "unit": "mm"
        },
        {
          "label": "Exhaust as a continuous gap along the ridge",
          "value": 13.333333333333334,
          "unit": "mm"
        },
        {
          "label": "Intake vent to fit",
          "value": 3,
          "unit": "vents (8 ft)"
        },
        {
          "label": "Exhaust vent to fit",
          "value": 20,
          "unit": "ft"
        },
        {
          "label": "High-level share of the total",
          "value": 50,
          "unit": "%"
        }
      ],
      "basis": "cited",
      "sourceIndex": 2
    },
    {
      "name": "BS 5250, pitch over 15° and under 35°, 12 x 8 m: 10 mm along both 12 m eaves, no ridge vent at an 8 m span",
      "inputs": {
        "atticLength": 12,
        "atticWidth": 8,
        "hasVaporBarrier": "ukMid",
        "exhaustShare": 50,
        "intakeVent": "soffit",
        "intakeArea": 0.01,
        "exhaustVent": "ridge",
        "exhaustArea": 0.005
      },
      "expected": 2.58334,
      "toleranceDecimalPlaces": 4,
      "unit": "sq ft (net free area)",
      "confidence": "medium",
      "steps": [
        {
          "label": "Attic floor area",
          "value": 1033.3354000041334,
          "unit": "sq ft"
        },
        {
          "label": "Net free area needed",
          "value": 240000,
          "unit": "mm²"
        },
        {
          "label": "Intake, low on the roof (eaves or soffit)",
          "value": 240000,
          "unit": "mm²"
        },
        {
          "label": "Exhaust, high on the roof (ridge or upper vents)",
          "value": 0,
          "unit": "mm²"
        },
        {
          "label": "Intake as a continuous gap along both eaves",
          "value": 10,
          "unit": "mm"
        },
        {
          "label": "Exhaust as a continuous gap along the ridge",
          "value": 0,
          "unit": "mm"
        },
        {
          "label": "Intake vent to fit",
          "value": 10,
          "unit": "vents (8 ft)"
        },
        {
          "label": "Exhaust vent to fit",
          "value": 0,
          "unit": "ft"
        },
        {
          "label": "High-level share of the total",
          "value": 0,
          "unit": "%"
        }
      ],
      "basis": "cited",
      "sourceIndex": 3
    },
    {
      "name": "BS 5250, pitch 35° or more, 12 x 8 m: eaves 0.24 m² and a 5 mm ridge, 0.06 m², 3.229 sq ft",
      "inputs": {
        "atticLength": 12,
        "atticWidth": 8,
        "hasVaporBarrier": "ukSteep",
        "exhaustShare": 50,
        "intakeVent": "soffit",
        "intakeArea": 0.01,
        "exhaustVent": "ridge",
        "exhaustArea": 0.005
      },
      "expected": 3.22917,
      "toleranceDecimalPlaces": 4,
      "unit": "sq ft (net free area)",
      "confidence": "medium",
      "steps": [
        {
          "label": "Attic floor area",
          "value": 1033.3354000041334,
          "unit": "sq ft"
        },
        {
          "label": "Net free area needed",
          "value": 300000,
          "unit": "mm²"
        },
        {
          "label": "Intake, low on the roof (eaves or soffit)",
          "value": 240000,
          "unit": "mm²"
        },
        {
          "label": "Exhaust, high on the roof (ridge or upper vents)",
          "value": 60000,
          "unit": "mm²"
        },
        {
          "label": "Intake as a continuous gap along both eaves",
          "value": 10,
          "unit": "mm"
        },
        {
          "label": "Exhaust as a continuous gap along the ridge",
          "value": 5,
          "unit": "mm"
        },
        {
          "label": "Intake vent to fit",
          "value": 10,
          "unit": "vents (8 ft)"
        },
        {
          "label": "Exhaust vent to fit",
          "value": 40,
          "unit": "ft"
        },
        {
          "label": "High-level share of the total",
          "value": 20,
          "unit": "%"
        }
      ],
      "basis": "cited",
      "sourceIndex": 3
    },
    {
      "name": "NBC 9.19.1.2 below a one-in-six slope, with vents rated by the reader: 1/150 of 12 x 7.5 m, 6.458 sq ft",
      "inputs": {
        "atticLength": 12,
        "atticWidth": 7.5,
        "hasVaporBarrier": "nbcLow",
        "exhaustShare": 50,
        "intakeVent": "custom",
        "intakeArea": 0.01,
        "exhaustVent": "custom",
        "exhaustArea": 0.026458
      },
      "expected": 6.45835,
      "toleranceDecimalPlaces": 4,
      "unit": "sq ft (net free area)",
      "confidence": "medium",
      "steps": [
        {
          "label": "Attic floor area",
          "value": 968.751937503875,
          "unit": "sq ft"
        },
        {
          "label": "Net free area needed",
          "value": 600000,
          "unit": "mm²"
        },
        {
          "label": "Intake, low on the roof (eaves or soffit)",
          "value": 317496,
          "unit": "mm²"
        },
        {
          "label": "Exhaust, high on the roof (ridge or upper vents)",
          "value": 300000,
          "unit": "mm²"
        },
        {
          "label": "Intake as a continuous gap along both eaves",
          "value": 13.229,
          "unit": "mm"
        },
        {
          "label": "Exhaust as a continuous gap along the ridge",
          "value": 24.999999999999996,
          "unit": "mm"
        },
        {
          "label": "Intake vent to fit",
          "value": 32,
          "unit": "vents"
        },
        {
          "label": "Exhaust vent to fit",
          "value": 12,
          "unit": "vents"
        },
        {
          "label": "High-level share of the total",
          "value": 50,
          "unit": "%"
        }
      ],
      "basis": "cited",
      "sourceIndex": 2
    },
    {
      "name": "BS 5250, pitch 15° or less over an 11 m span: 25 mm at both eaves and 5 mm at high level, 7.104 sq ft",
      "inputs": {
        "atticLength": 12,
        "atticWidth": 11,
        "hasVaporBarrier": "ukLow",
        "exhaustShare": 50,
        "intakeVent": "custom",
        "intakeArea": 0.01,
        "exhaustVent": "custom",
        "exhaustArea": 0.026458
      },
      "expected": 7.10418,
      "toleranceDecimalPlaces": 4,
      "unit": "sq ft (net free area)",
      "confidence": "medium",
      "steps": [
        {
          "label": "Attic floor area",
          "value": 1420.8361750056833,
          "unit": "sq ft"
        },
        {
          "label": "Net free area needed",
          "value": 660000.0000000001,
          "unit": "mm²"
        },
        {
          "label": "Intake, low on the roof (eaves or soffit)",
          "value": 600000.0000000001,
          "unit": "mm²"
        },
        {
          "label": "Exhaust, high on the roof (ridge or upper vents)",
          "value": 60000,
          "unit": "mm²"
        },
        {
          "label": "Intake as a continuous gap along both eaves",
          "value": 25.000000000000004,
          "unit": "mm"
        },
        {
          "label": "Exhaust as a continuous gap along the ridge",
          "value": 5,
          "unit": "mm"
        },
        {
          "label": "Intake vent to fit",
          "value": 60,
          "unit": "vents"
        },
        {
          "label": "Exhaust vent to fit",
          "value": 3,
          "unit": "vents"
        },
        {
          "label": "High-level share of the total",
          "value": 9.090909090909088,
          "unit": "%"
        }
      ],
      "basis": "cited",
      "sourceIndex": 3
    },
    {
      "name": "NCC 2022 Table 10.8.3, pitch 15° to under 75°, 12 x 7.5 m: 7,000 mm² a metre at each eave and 5,000 high up, 2.454 sq ft",
      "inputs": {
        "atticLength": 12,
        "atticWidth": 7.5,
        "hasVaporBarrier": "auSteep",
        "exhaustShare": 50,
        "intakeVent": "soffit",
        "intakeArea": 0.025,
        "exhaustVent": "ridge",
        "exhaustArea": 0.026458
      },
      "expected": 2.45417,
      "toleranceDecimalPlaces": 4,
      "unit": "sq ft (net free area)",
      "confidence": "medium",
      "steps": [
        {
          "label": "Attic floor area",
          "value": 968.751937503875,
          "unit": "sq ft"
        },
        {
          "label": "Net free area needed",
          "value": 228000,
          "unit": "mm²"
        },
        {
          "label": "Intake, low on the roof (eaves or soffit)",
          "value": 168000,
          "unit": "mm²"
        },
        {
          "label": "Exhaust, high on the roof (ridge or upper vents)",
          "value": 60000,
          "unit": "mm²"
        },
        {
          "label": "Intake as a continuous gap along both eaves",
          "value": 7,
          "unit": "mm"
        },
        {
          "label": "Exhaust as a continuous gap along the ridge",
          "value": 5,
          "unit": "mm"
        },
        {
          "label": "Intake vent to fit",
          "value": 10,
          "unit": "vents (8 ft)"
        },
        {
          "label": "Exhaust vent to fit",
          "value": 40,
          "unit": "ft"
        },
        {
          "label": "High-level share of the total",
          "value": 26.31578947368421,
          "unit": "%"
        }
      ],
      "basis": "cited",
      "sourceIndex": 6
    },
    {
      "name": "NCC 2022 Table 10.8.3, pitch 10° to under 15°, 12 x 7.5 m: 25,000 mm² a metre at each eave and 5,000 high up, 7.104 sq ft",
      "inputs": {
        "atticLength": 12,
        "atticWidth": 7.5,
        "hasVaporBarrier": "auMid",
        "exhaustShare": 50,
        "intakeVent": "soffit",
        "intakeArea": 0.025,
        "exhaustVent": "ridge",
        "exhaustArea": 0.026458
      },
      "expected": 7.10418,
      "toleranceDecimalPlaces": 4,
      "unit": "sq ft (net free area)",
      "confidence": "medium",
      "steps": [
        {
          "label": "Attic floor area",
          "value": 968.751937503875,
          "unit": "sq ft"
        },
        {
          "label": "Net free area needed",
          "value": 660000.0000000001,
          "unit": "mm²"
        },
        {
          "label": "Intake, low on the roof (eaves or soffit)",
          "value": 600000.0000000001,
          "unit": "mm²"
        },
        {
          "label": "Exhaust, high on the roof (ridge or upper vents)",
          "value": 60000,
          "unit": "mm²"
        },
        {
          "label": "Intake as a continuous gap along both eaves",
          "value": 25.000000000000004,
          "unit": "mm"
        },
        {
          "label": "Exhaust as a continuous gap along the ridge",
          "value": 5,
          "unit": "mm"
        },
        {
          "label": "Intake vent to fit",
          "value": 11,
          "unit": "vents (8 ft)"
        },
        {
          "label": "Exhaust vent to fit",
          "value": 40,
          "unit": "ft"
        },
        {
          "label": "High-level share of the total",
          "value": 9.090909090909088,
          "unit": "%"
        }
      ],
      "basis": "cited",
      "sourceIndex": 6
    },
    {
      "name": "NCC 2022 Table 10.8.3, pitch under 10°, a 8 x 10 m roof whose width is its longest side: 25,000 mm² a metre at each of two ends, 5.382 sq ft",
      "inputs": {
        "atticLength": 8,
        "atticWidth": 10,
        "hasVaporBarrier": "auLow",
        "exhaustShare": 50,
        "intakeVent": "soffit",
        "intakeArea": 0.025,
        "exhaustVent": "ridge",
        "exhaustArea": 0.026458
      },
      "expected": 5.38196,
      "toleranceDecimalPlaces": 4,
      "unit": "sq ft (net free area)",
      "confidence": "medium",
      "steps": [
        {
          "label": "Attic floor area",
          "value": 861.1128333367777,
          "unit": "sq ft"
        },
        {
          "label": "Net free area needed",
          "value": 500000,
          "unit": "mm²"
        },
        {
          "label": "Intake, low on the roof (eaves or soffit)",
          "value": 500000,
          "unit": "mm²"
        },
        {
          "label": "Exhaust, high on the roof (ridge or upper vents)",
          "value": 0,
          "unit": "mm²"
        },
        {
          "label": "Intake as a continuous gap along both eaves",
          "value": 31.25,
          "unit": "mm"
        },
        {
          "label": "Exhaust as a continuous gap along the ridge",
          "value": 0,
          "unit": "mm"
        },
        {
          "label": "Intake vent to fit",
          "value": 9,
          "unit": "vents (8 ft)"
        },
        {
          "label": "Exhaust vent to fit",
          "value": 0,
          "unit": "ft"
        },
        {
          "label": "High-level share of the total",
          "value": 0,
          "unit": "%"
        }
      ],
      "basis": "cited",
      "sourceIndex": 6
    }
  ]
}