  "version": "v1",
  "source": "https://craftquantities.com",
  "licence": "CC BY 4.0",
  "licenceUrl": "https://creativecommons.org/licenses/by/4.0/",
  "attribution": "Craft Quantities — craftquantities.com",
  "documentation": "https://craftquantities.com/api/",
  "versioning": "Fields are added, never removed or repurposed, within a version. A breaking change becomes /api/v2/ and v1 keeps being built.",
  "slug": "attic-bypass-sealing-material-calculator",
  "category": "insulation-efficiency",
  "title": "Attic Bypass Sealing Material Calculator",
  "description": "Turn an attic's bypass schedule (chases, soffits, housings, plate runs, penetrations, flues) into sealant tubes, foam cans, rigid board and sheet metal.",
  "url": "https://craftquantities.com/calculators/insulation-efficiency/attic-bypass-sealing-material-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/attic-bypass-sealing-material-calculator.json",
  "inputCount": 12,
  "testCaseCount": 3,
  "sourceCount": 4,
  "lastVerified": "2026-09-06",
  "translations": {
    "es-US": "https://craftquantities.com/es/calculators/insulation-efficiency/attic-bypass-sealing-material-calculator/"
  },
  "citation": {
    "author": "Craft Quantities",
    "title": "Attic Bypass Sealing Material Calculator",
    "version": "1.0.1",
    "sourcesChecked": "2026-09-06",
    "url": "https://craftquantities.com/calculators/insulation-efficiency/attic-bypass-sealing-material-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. Attic Bypass Sealing Material Calculator. Version 1.0.1. Sources checked 2026-09-06. https://craftquantities.com/calculators/insulation-efficiency/attic-bypass-sealing-material-calculator/",
      "apa": "Craft Quantities. (2026). Attic Bypass Sealing Material Calculator (Version 1.0.1) [Web calculator]. Retrieved from https://craftquantities.com/calculators/insulation-efficiency/attic-bypass-sealing-material-calculator/",
      "harvard": "Craft Quantities (2026) Attic Bypass Sealing Material Calculator (Version 1.0.1). Available at: https://craftquantities.com/calculators/insulation-efficiency/attic-bypass-sealing-material-calculator/",
      "bibtex": "@misc{craftquantities-calculators-insulation-efficiency-attic-bypass-sealing-material-calculator,\n  author       = {{Craft Quantities}},\n  title        = {Attic Bypass Sealing Material Calculator},\n  version      = {1.0.1},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/insulation-efficiency/attic-bypass-sealing-material-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "chaseCount",
      "label": "Number of Open Chases",
      "type": "number",
      "defaultValue": 4,
      "min": 0,
      "max": 40,
      "step": 1,
      "help": "How many open chases the ceiling plane has — around flues, stacks and ductwork."
    },
    {
      "id": "chaseArea",
      "label": "Combined Plan Area of the Chases",
      "type": "number",
      "dimension": "area",
      "defaultValue": 1.6,
      "min": 0.05,
      "max": 50,
      "step": 0.1,
      "help": "The total opening area of those chases, measured on the attic floor."
    },
    {
      "id": "soffitLength",
      "label": "Running Length of Dropped Soffits and Open Partition Tops",
      "type": "number",
      "dimension": "length",
      "defaultValue": 6,
      "min": 0,
      "max": 200,
      "step": 0.5,
      "help": "Total run of dropped soffits over cabinets and baths, plus balloon-framed partitions open at the top."
    },
    {
      "id": "soffitWidth",
      "label": "Typical Width of Those Soffits",
      "type": "number",
      "dimension": "length",
      "defaultValue": 0.6,
      "min": 0.1,
      "max": 2,
      "step": 0.05,
      "help": "How wide the open strip is across the run."
    },
    {
      "id": "topPlateLength",
      "label": "Running Length of Top-Plate Joint",
      "type": "number",
      "dimension": "length",
      "defaultValue": 45,
      "min": 0,
      "max": 500,
      "step": 1,
      "help": "Total run of the joint between the top plates and the ceiling board below."
    },
    {
      "id": "housingCount",
      "label": "Recessed Luminaire and Fan Housings",
      "type": "number",
      "defaultValue": 8,
      "min": 0,
      "max": 100,
      "step": 1,
      "help": "How many recessed light and exhaust fan housings break the ceiling plane."
    },
    {
      "id": "housingDiameter",
      "label": "Sealed Diameter at a Housing",
      "type": "number",
      "dimension": "length",
      "defaultValue": 0.19,
      "min": 0.05,
      "max": 0.6,
      "step": 0.01,
      "help": "Across the joint you will actually run a bead around at each housing."
    },
    {
      "id": "penetrationCount",
      "label": "Annular Penetrations",
      "type": "number",
      "defaultValue": 25,
      "min": 0,
      "max": 300,
      "step": 1,
      "help": "Wires, small pipes and refrigerant lines passing through the ceiling plane."
    },
    {
      "id": "penetrationsPerCan",
      "label": "Penetrations Sealed per Foam Can",
      "type": "number",
      "defaultValue": 25,
      "min": 5,
      "max": 100,
      "step": 1,
      "help": "How many small annular gaps one can of one-part foam will fill."
    },
    {
      "id": "flueCount",
      "label": "Flues and Chimneys Needing a Metal Dam",
      "type": "number",
      "defaultValue": 1,
      "min": 0,
      "max": 10,
      "step": 1,
      "help": "How many flues or chimneys pass through the ceiling plane."
    },
    {
      "id": "flueSize",
      "label": "Largest Plan Dimension of the Flue",
      "type": "number",
      "dimension": "length",
      "defaultValue": 0.25,
      "min": 0.05,
      "max": 1.2,
      "step": 0.01,
      "help": "Across the flue or chimney as it passes the ceiling, at its widest."
    },
    {
      "id": "flueClearance",
      "label": "Required Clearance to Combustibles",
      "type": "number",
      "dimension": "length",
      "defaultValue": 0.05,
      "min": 0.005,
      "max": 0.3,
      "step": 0.005,
      "help": "The clearance the appliance listing and the adopted code require around this flue."
    }
  ],
  "sources": [
    {
      "label": "Bead length one gunnable cartridge lays down is a RULE OF THUMB, stated as one: about 25 linear ft (7.62 m) from a 10.1 oz cartridge at a quarter-inch bead. Bead width is what moves it, so a wide plate joint consumes the allowance faster than the arithmetic suggests."
    },
    {
      "label": "ASTM E779, Standard Test Method for Determining Air Leakage Rate by Fan Pressurization — the before-and-after measurement that tells you whether the schedule you sealed was the schedule that mattered"
    },
    {
      "label": "Chase and soffit perimeters are estimated geometrically: a chase is treated as square, so its edge is four times the square root of its own plan area, and a soffit run is treated as one rectangle. Both are approximations and both are stated on the page."
    },
    {
      "label": "Foam can yield is a PRODUCT figure and is left as an input rather than assumed. The default of 25 small annular penetrations per can is an ordering rule of thumb; the yield printed on the can supersedes it."
    }
  ],
  "testCases": [
    {
      "name": "Typical single-storey ceiling: 4 chases, 6 m of soffit, 45 m of plate",
      "inputs": {
        "chaseCount": 4,
        "chaseArea": 1.6,
        "soffitLength": 6,
        "soffitWidth": 0.6,
        "topPlateLength": 45,
        "housingCount": 8,
        "housingDiameter": 0.19,
        "penetrationCount": 25,
        "penetrationsPerCan": 25,
        "flueCount": 1,
        "flueSize": 0.25,
        "flueClearance": 0.05
      },
      "expected": 11,
      "toleranceDecimalPlaces": 0,
      "unit": "tubes",
      "confidence": "medium",
      "steps": [
        {
          "label": "One-part foam cans",
          "value": 1,
          "unit": "cans"
        },
        {
          "label": "Rigid board over chases and soffits",
          "value": 5.72,
          "unit": "m²"
        },
        {
          "label": "Sheet metal at flues",
          "value": 0.12249999999999998,
          "unit": "m²"
        },
        {
          "label": "Sealed bead run including the cut allowance",
          "value": 80.40396028059483,
          "unit": "m"
        }
      ],
      "includesAllowance": {
        "label": "Cut, start and stop allowance",
        "percent": 10
      },
      "basis": "ambiguous"
    },
    {
      "name": "Larger house: 6 chases, 8 m of soffit, 60 m of plate",
      "inputs": {
        "chaseCount": 6,
        "chaseArea": 2.2,
        "soffitLength": 8,
        "soffitWidth": 0.6,
        "topPlateLength": 60,
        "housingCount": 12,
        "housingDiameter": 0.19,
        "penetrationCount": 40,
        "penetrationsPerCan": 25,
        "flueCount": 1,
        "flueSize": 0.25,
        "flueClearance": 0.05
      },
      "expected": 15,
      "toleranceDecimalPlaces": 0,
      "unit": "tubes",
      "confidence": "medium",
      "steps": [
        {
          "label": "One-part foam cans",
          "value": 2,
          "unit": "cans"
        },
        {
          "label": "Rigid board over chases and soffits",
          "value": 7.700000000000001,
          "unit": "m²"
        },
        {
          "label": "Sheet metal at flues",
          "value": 0.12249999999999998,
          "unit": "m²"
        },
        {
          "label": "Sealed bead run including the cut allowance",
          "value": 108.78510824483796,
          "unit": "m"
        }
      ],
      "includesAllowance": {
        "label": "Cut, start and stop allowance",
        "percent": 10
      },
      "basis": "ambiguous"
    },
    {
      "name": "Single bedroom addition: one chase, no soffit, no flue",
      "inputs": {
        "chaseCount": 1,
        "chaseArea": 0.5,
        "soffitLength": 0,
        "soffitWidth": 0.6,
        "topPlateLength": 12,
        "housingCount": 2,
        "housingDiameter": 0.19,
        "penetrationCount": 8,
        "penetrationsPerCan": 25,
        "flueCount": 0,
        "flueSize": 0.25,
        "flueClearance": 0.05
      },
      "expected": 3,
      "toleranceDecimalPlaces": 0,
      "unit": "tubes",
      "confidence": "medium",
      "steps": [
        {
          "label": "One-part foam cans",
          "value": 1,
          "unit": "cans"
        },
        {
          "label": "Rigid board over chases and soffits",
          "value": 0.55,
          "unit": "m²"
        },
        {
          "label": "Sheet metal at flues",
          "value": 0,
          "unit": "m²"
        },
        {
          "label": "Sealed bead run including the cut allowance",
          "value": 17.624455566421343,
          "unit": "m"
        }
      ],
      "includesAllowance": {
        "label": "Cut, start and stop allowance",
        "percent": 10
      },
      "basis": "ambiguous"
    }
  ]
}