  "version": "v1",
  "source": "https://craftquantities.com",
  "licence": "CC BY 4.0",
  "licenceUrl": "https://creativecommons.org/licenses/by/4.0/",
  "attribution": "Craft Quantities — craftquantities.com",
  "documentation": "https://craftquantities.com/api/",
  "versioning": "Fields are added, never removed or repurposed, within a version. A breaking change becomes /api/v2/ and v1 keeps being built.",
  "slug": "anchor-proof-load-test-calculator",
  "category": "materials-quantities",
  "title": "Concrete Anchor Proof Load Test Calculator",
  "description": "The load a site proof test on concrete anchors is held at, and how many anchors in a lot to pull, from your specification's multiplier and sample rate.",
  "url": "https://craftquantities.com/calculators/materials-quantities/anchor-proof-load-test-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/anchor-proof-load-test-calculator.json",
  "inputCount": 5,
  "testCaseCount": 3,
  "sourceCount": 3,
  "lastVerified": "2026-09-02",
  "citation": {
    "author": "Craft Quantities",
    "title": "Concrete Anchor Proof Load Test Calculator",
    "version": "1.0.1",
    "sourcesChecked": "2026-09-02",
    "url": "https://craftquantities.com/calculators/materials-quantities/anchor-proof-load-test-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. Concrete Anchor Proof Load Test Calculator. Version 1.0.1. Sources checked 2026-09-02. https://craftquantities.com/calculators/materials-quantities/anchor-proof-load-test-calculator/",
      "apa": "Craft Quantities. (2026). Concrete Anchor Proof Load Test Calculator (Version 1.0.1) [Web calculator]. Retrieved from https://craftquantities.com/calculators/materials-quantities/anchor-proof-load-test-calculator/",
      "harvard": "Craft Quantities (2026) Concrete Anchor Proof Load Test Calculator (Version 1.0.1). Available at: https://craftquantities.com/calculators/materials-quantities/anchor-proof-load-test-calculator/",
      "bibtex": "@misc{craftquantities-calculators-materials-quantities-anchor-proof-load-test-calculator,\n  author       = {{Craft Quantities}},\n  title        = {Concrete Anchor Proof Load Test Calculator},\n  version      = {1.0.1},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/materials-quantities/anchor-proof-load-test-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "designTension",
      "label": "Design Tension per Anchor",
      "type": "number",
      "dimension": "force",
      "defaultValue": 8000,
      "min": 500,
      "max": 400000,
      "step": 250,
      "help": "The tension the anchor is designed to carry in service."
    },
    {
      "id": "proofMultiplier",
      "label": "Specified Proof-Load Multiplier",
      "type": "number",
      "defaultValue": 1.5,
      "min": 1,
      "max": 3,
      "step": 0.05,
      "help": "How many times the design tension the specification asks the test to reach."
    },
    {
      "id": "lotSize",
      "label": "Anchors in the Test Lot",
      "type": "number",
      "defaultValue": 120,
      "min": 1,
      "max": 5000,
      "step": 1,
      "help": "How many anchors this lot covers — one installer, one product, one condition."
    },
    {
      "id": "samplePercent",
      "label": "Specified Sample Rate",
      "type": "number",
      "defaultValue": 5,
      "min": 0.5,
      "max": 100,
      "step": 0.5,
      "help": "The proportion of the lot the specification requires to be tested."
    },
    {
      "id": "minimumTests",
      "label": "Specified Minimum per Lot",
      "type": "number",
      "defaultValue": 2,
      "min": 0,
      "max": 50,
      "step": 1,
      "help": "The floor the specification puts under the sample, whatever the percentage gives."
    }
  ],
  "sources": [
    {
      "label": "ASTM E488/E488M, Standard Test Methods for Strength of Anchors in Concrete Elements — the reference method for applying and measuring a tension load on an installed anchor"
    },
    {
      "label": "The proof-load multiplier and the sampling rate are project values, not standard ones: they come from the contract specification and the special inspection programme, which is why both are entered here rather than assumed"
    },
    {
      "label": "Arithmetic only: proof load = design tension × the specified multiplier; anchors to test = the specified percentage of the lot, rounded up, subject to the specified minimum and never more than the lot holds"
    }
  ],
  "testCases": [
    {
      "name": "8 kN design tension at 1.5x, 5% of 120 anchors",
      "inputs": {
        "designTension": 8000,
        "proofMultiplier": 1.5,
        "lotSize": 120,
        "samplePercent": 5,
        "minimumTests": 2
      },
      "expected": 12000,
      "toleranceDecimalPlaces": 1,
      "unit": "N",
      "confidence": "medium",
      "steps": [
        {
          "label": "Anchors to test in this lot",
          "value": 6,
          "unit": "anchors"
        },
        {
          "label": "Sample size before the specified floor",
          "value": 6,
          "unit": "anchors"
        },
        {
          "label": "Load applied above the design tension",
          "value": 4000,
          "unit": "N"
        },
        {
          "label": "Anchors covered by each tested anchor",
          "value": 20,
          "unit": "anchors"
        }
      ],
      "basis": "ambiguous"
    },
    {
      "name": "15 kN design tension at 2.0x, 10% of 40 anchors",
      "inputs": {
        "designTension": 15000,
        "proofMultiplier": 2,
        "lotSize": 40,
        "samplePercent": 10,
        "minimumTests": 2
      },
      "expected": 30000,
      "toleranceDecimalPlaces": 1,
      "unit": "N",
      "confidence": "medium",
      "steps": [
        {
          "label": "Anchors to test in this lot",
          "value": 4,
          "unit": "anchors"
        },
        {
          "label": "Sample size before the specified floor",
          "value": 4,
          "unit": "anchors"
        },
        {
          "label": "Load applied above the design tension",
          "value": 15000,
          "unit": "N"
        },
        {
          "label": "Anchors covered by each tested anchor",
          "value": 10,
          "unit": "anchors"
        }
      ],
      "basis": "ambiguous"
    },
    {
      "name": "Small lot where the specified floor governs the sample",
      "inputs": {
        "designTension": 4500,
        "proofMultiplier": 1.25,
        "lotSize": 8,
        "samplePercent": 5,
        "minimumTests": 3
      },
      "expected": 5625,
      "toleranceDecimalPlaces": 1,
      "unit": "N",
      "confidence": "medium",
      "steps": [
        {
          "label": "Anchors to test in this lot",
          "value": 3,
          "unit": "anchors"
        },
        {
          "label": "Sample size before the specified floor",
          "value": 1,
          "unit": "anchors"
        },
        {
          "label": "Load applied above the design tension",
          "value": 1125,
          "unit": "N"
        },
        {
          "label": "Anchors covered by each tested anchor",
          "value": 2.6666666666666665,
          "unit": "anchors"
        }
      ],
      "basis": "ambiguous"
    }
  ]
}