  "version": "v1",
  "source": "https://craftquantities.com",
  "licence": "CC BY 4.0",
  "licenceUrl": "https://creativecommons.org/licenses/by/4.0/",
  "attribution": "Craft Quantities — craftquantities.com",
  "documentation": "https://craftquantities.com/api/",
  "versioning": "Fields are added, never removed or repurposed, within a version. A breaking change becomes /api/v2/ and v1 keeps being built.",
  "slug": "acoustic-reflector-panel-calculator",
  "category": "materials-quantities",
  "title": "Acoustic Reflector Panel Placement Calculator",
  "description": "Calculate the specular reflection point and incidence angle for a flat acoustic reflector panel, using the image-source method.",
  "url": "https://craftquantities.com/calculators/materials-quantities/acoustic-reflector-panel-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/acoustic-reflector-panel-calculator.json",
  "inputCount": 3,
  "testCaseCount": 2,
  "sourceCount": 1,
  "lastVerified": "2026-09-06",
  "citation": {
    "author": "Craft Quantities",
    "title": "Acoustic Reflector Panel Placement Calculator",
    "version": "1.0.1",
    "sourcesChecked": "2026-09-06",
    "url": "https://craftquantities.com/calculators/materials-quantities/acoustic-reflector-panel-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. Acoustic Reflector Panel Placement Calculator. Version 1.0.1. Sources checked 2026-09-06. https://craftquantities.com/calculators/materials-quantities/acoustic-reflector-panel-calculator/",
      "apa": "Craft Quantities. (2026). Acoustic Reflector Panel Placement Calculator (Version 1.0.1) [Web calculator]. Retrieved from https://craftquantities.com/calculators/materials-quantities/acoustic-reflector-panel-calculator/",
      "harvard": "Craft Quantities (2026) Acoustic Reflector Panel Placement Calculator (Version 1.0.1). Available at: https://craftquantities.com/calculators/materials-quantities/acoustic-reflector-panel-calculator/",
      "bibtex": "@misc{craftquantities-calculators-materials-quantities-acoustic-reflector-panel-calculator,\n  author       = {{Craft Quantities}},\n  title        = {Acoustic Reflector Panel Placement Calculator},\n  version      = {1.0.1},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/materials-quantities/acoustic-reflector-panel-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "sourceHeight",
      "label": "Source Height Below Reflector Plane",
      "type": "number",
      "dimension": "length",
      "defaultValue": 3,
      "min": 0.01,
      "max": 15,
      "step": 0.1,
      "help": "The vertical distance from the sound source (e.g. loudspeaker) up to the reflector panel plane."
    },
    {
      "id": "receiverHeight",
      "label": "Receiver (Listener) Height Below Reflector Plane",
      "type": "number",
      "dimension": "length",
      "defaultValue": 1.5,
      "min": 0.01,
      "max": 10,
      "step": 0.1,
      "help": "The vertical distance from the listener's ear height up to the reflector panel plane."
    },
    {
      "id": "horizontalDistance",
      "label": "Horizontal Distance Between Source and Receiver",
      "type": "number",
      "dimension": "length",
      "defaultValue": 10,
      "min": 0.01,
      "max": 60,
      "step": 0.5,
      "help": "The horizontal distance between the sound source and the receiver/listener position."
    }
  ],
  "sources": [
    {
      "label": "Image-source (mirror) method for specular sound reflection: for a source and receiver on the same side of a flat reflecting plane, the reflection point along the plane is located at a distance from the point below the source equal to (horizontal distance × source height) ÷ (source height + receiver height) — this locates the point where the law of reflection (angle of incidence = angle of reflection) is satisfied, the standard geometric acoustics method used in architectural acoustic reflector design."
    }
  ],
  "testCases": [
    {
      "name": "3m source, 1.5m receiver, 10m apart",
      "inputs": {
        "sourceHeight": 3,
        "receiverHeight": 1.5,
        "horizontalDistance": 10
      },
      "expected": 6.667,
      "toleranceDecimalPlaces": 1,
      "unit": "m (from point below source)",
      "confidence": "medium",
      "steps": [
        {
          "label": "Angle of incidence/reflection from panel normal",
          "value": 65.77225468204583,
          "unit": "°"
        }
      ],
      "basis": "sole-source",
      "sourceIndex": 0
    },
    {
      "name": "4m source, 1.2m receiver, 12m apart",
      "inputs": {
        "sourceHeight": 4,
        "receiverHeight": 1.2,
        "horizontalDistance": 12
      },
      "expected": 9.231,
      "toleranceDecimalPlaces": 1,
      "unit": "m (from point below source)",
      "confidence": "medium",
      "steps": [
        {
          "label": "Angle of incidence/reflection from panel normal",
          "value": 66.5713071912546,
          "unit": "°"
        }
      ],
      "basis": "sole-source",
      "sourceIndex": 0
    }
  ]
}