  "version": "v1",
  "source": "https://craftquantities.com",
  "licence": "CC BY 4.0",
  "licenceUrl": "https://creativecommons.org/licenses/by/4.0/",
  "attribution": "Craft Quantities — craftquantities.com",
  "documentation": "https://craftquantities.com/api/",
  "versioning": "Fields are added, never removed or repurposed, within a version. A breaking change becomes /api/v2/ and v1 keeps being built.",
  "slug": "ac-size-calculator",
  "category": "plumbing-hvac",
  "title": "Air Conditioner Size Calculator",
  "description": "Estimate the cooling capacity a space needs in BTU/h and tons, adjusted for climate, insulation, glazing and occupancy.",
  "url": "https://craftquantities.com/calculators/plumbing-hvac/ac-size-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/ac-size-calculator.json",
  "inputCount": 6,
  "testCaseCount": 4,
  "sourceCount": 3,
  "lastVerified": "2026-10-31",
  "translations": {
    "es-US": "https://craftquantities.com/es/calculators/plumbing-hvac/ac-size-calculator/"
  },
  "citation": {
    "author": "Craft Quantities",
    "title": "Air Conditioner Size Calculator",
    "version": "1.1.0",
    "sourcesChecked": "2026-10-31",
    "url": "https://craftquantities.com/calculators/plumbing-hvac/ac-size-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. Air Conditioner Size Calculator. Version 1.1.0. Sources checked 2026-10-31. https://craftquantities.com/calculators/plumbing-hvac/ac-size-calculator/",
      "apa": "Craft Quantities. (2026). Air Conditioner Size Calculator (Version 1.1.0) [Web calculator]. Retrieved from https://craftquantities.com/calculators/plumbing-hvac/ac-size-calculator/",
      "harvard": "Craft Quantities (2026) Air Conditioner Size Calculator (Version 1.1.0). Available at: https://craftquantities.com/calculators/plumbing-hvac/ac-size-calculator/",
      "bibtex": "@misc{craftquantities-calculators-plumbing-hvac-ac-size-calculator,\n  author       = {{Craft Quantities}},\n  title        = {Air Conditioner Size Calculator},\n  version      = {1.1.0},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/plumbing-hvac/ac-size-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "floorArea",
      "label": "Floor area",
      "type": "number",
      "dimension": "area",
      "defaultValue": 100,
      "min": 0.01,
      "max": 2000,
      "step": 1,
      "help": "Conditioned floor area of the space."
    },
    {
      "id": "climate",
      "label": "Climate",
      "type": "select",
      "defaultValue": "moderate",
      "options": [
        {
          "value": "mild",
          "label": "Mild — cool summers, rarely above 27 °C / 80 °F"
        },
        {
          "value": "moderate",
          "label": "Moderate — warm summers, 27-32 °C / 80-90 °F"
        },
        {
          "value": "hot",
          "label": "Hot — 32-38 °C / 90-100 °F design day"
        },
        {
          "value": "veryHot",
          "label": "Very hot — above 38 °C / 100 °F, or hot and humid"
        }
      ],
      "help": "Summer design conditions where the building is."
    },
    {
      "id": "insulation",
      "label": "Insulation and airtightness",
      "type": "select",
      "defaultValue": "average",
      "options": [
        {
          "value": "poor",
          "label": "Poor — little insulation, draughty, older construction"
        },
        {
          "value": "average",
          "label": "Average — insulated to code when built"
        },
        {
          "value": "good",
          "label": "Good — well insulated, tight, modern or upgraded"
        }
      ],
      "help": "Overall thermal quality of the envelope."
    },
    {
      "id": "sunExposure",
      "label": "Sun exposure",
      "type": "select",
      "defaultValue": "average",
      "options": [
        {
          "value": "shaded",
          "label": "Mostly shaded — little or no direct afternoon sun on the glazing"
        },
        {
          "value": "average",
          "label": "Average glazing and exposure"
        },
        {
          "value": "heavy",
          "label": "Large unshaded glazing taking direct afternoon and evening sun"
        }
      ],
      "help": "How much solar gain the space takes."
    },
    {
      "id": "occupants",
      "label": "Regular occupants",
      "type": "number",
      "defaultValue": 2,
      "min": 0,
      "max": 100,
      "step": 1,
      "help": "People normally in the space."
    },
    {
      "id": "kitchen",
      "label": "Includes a kitchen",
      "type": "select",
      "defaultValue": "no",
      "options": [
        {
          "value": "no",
          "label": "No"
        },
        {
          "value": "yes",
          "label": "Yes — add for cooking equipment"
        }
      ],
      "help": "Cooking adds a substantial sensible and latent load."
    }
  ],
  "sources": [
    {
      "label": "ACCA Manual J (8th ed.) — residential load calculation. This page is a screening approximation of it, not an implementation."
    },
    {
      "label": "1 ton of refrigeration = 12,000 BTU/h (ASHRAE Terminology)"
    },
    {
      "label": "ACCA Manual S — equipment selection should follow the calculated load, not floor area alone"
    }
  ],
  "testCases": [
    {
      "name": "100 m² moderate, average, average, 2 people",
      "inputs": {
        "floorArea": 100,
        "climate": "moderate",
        "insulation": "average",
        "sunExposure": "average",
        "occupants": 2,
        "kitchen": "no"
      },
      "expected": 21527.82,
      "toleranceDecimalPlaces": -1,
      "unit": "BTU/h",
      "confidence": "low",
      "steps": [
        {
          "label": "Refrigeration tons",
          "value": 1.7939850694516204,
          "unit": "tons"
        },
        {
          "label": "Kilowatts",
          "value": 6.309181490126051,
          "unit": "kW"
        },
        {
          "label": "Envelope and solar",
          "value": 21527.820833419446,
          "unit": "BTU/h"
        },
        {
          "label": "Occupants beyond two",
          "value": 0,
          "unit": "BTU/h"
        },
        {
          "label": "Kitchen",
          "value": 0,
          "unit": "BTU/h"
        }
      ],
      "basis": "ambiguous"
    },
    {
      "name": "Poor insulation raises the load 25%",
      "inputs": {
        "floorArea": 100,
        "climate": "moderate",
        "insulation": "poor",
        "sunExposure": "average",
        "occupants": 2,
        "kitchen": "no"
      },
      "expected": 26909.78,
      "toleranceDecimalPlaces": -1,
      "unit": "BTU/h",
      "confidence": "low",
      "steps": [
        {
          "label": "Refrigeration tons",
          "value": 2.2424813368145258,
          "unit": "tons"
        },
        {
          "label": "Kilowatts",
          "value": 7.886476862657563,
          "unit": "kW"
        },
        {
          "label": "Envelope and solar",
          "value": 26909.77604177431,
          "unit": "BTU/h"
        },
        {
          "label": "Occupants beyond two",
          "value": 0,
          "unit": "BTU/h"
        },
        {
          "label": "Kitchen",
          "value": 0,
          "unit": "BTU/h"
        }
      ],
      "basis": "ambiguous"
    },
    {
      "name": "A hot climate and heavy sun",
      "inputs": {
        "floorArea": 100,
        "climate": "hot",
        "insulation": "average",
        "sunExposure": "heavy",
        "occupants": 2,
        "kitchen": "no"
      },
      "expected": 30945.24,
      "toleranceDecimalPlaces": -1,
      "unit": "BTU/h",
      "confidence": "low",
      "steps": [
        {
          "label": "Refrigeration tons",
          "value": 2.578853537336704,
          "unit": "tons"
        },
        {
          "label": "Kilowatts",
          "value": 9.069448392056197,
          "unit": "kW"
        },
        {
          "label": "Envelope and solar",
          "value": 30946.24244804045,
          "unit": "BTU/h"
        },
        {
          "label": "Occupants beyond two",
          "value": 0,
          "unit": "BTU/h"
        },
        {
          "label": "Kitchen",
          "value": 0,
          "unit": "BTU/h"
        }
      ],
      "basis": "ambiguous"
    },
    {
      "name": "Extra occupants and a kitchen add fixed load",
      "inputs": {
        "floorArea": 100,
        "climate": "moderate",
        "insulation": "average",
        "sunExposure": "average",
        "occupants": 5,
        "kitchen": "yes"
      },
      "expected": 27327.82,
      "toleranceDecimalPlaces": -1,
      "unit": "BTU/h",
      "confidence": "low",
      "steps": [
        {
          "label": "Refrigeration tons",
          "value": 2.277318402784954,
          "unit": "tons"
        },
        {
          "label": "Kilowatts",
          "value": 8.008993697124927,
          "unit": "kW"
        },
        {
          "label": "Envelope and solar",
          "value": 21527.820833419446,
          "unit": "BTU/h"
        },
        {
          "label": "Occupants beyond two",
          "value": 1800,
          "unit": "BTU/h"
        },
        {
          "label": "Kitchen",
          "value": 4000,
          "unit": "BTU/h"
        }
      ],
      "basis": "ambiguous"
    }
  ],
  "usedByAssemblies": [
    {
      "id": "mini-split-install",
      "name": "Mini-split installation"
    }
  ]
}